![Advanced Navigation Boreas D90 Скачать руководство пользователя страница 137](http://html.mh-extra.com/html/advanced-navigation/boreas-d90/boreas-d90_reference-manual_2856109137.webp)
11.4.1.5 Microseconds
This field provides the sub-second component of time. It is represented as microseconds since the last second.
Minimum value is 0 and maximum value is 999999.
11.4.2 Unix Time Packet
Unix Time Packet
Packet ID
21
Length
8
Read / Write
Read
Field #
Bytes Offset
Data Type
Size
Description
1
0
u32
4
Unix time stamp (seconds). See
2
4
u32
4
Table 63: Unix Time Packet
11.4.3 Formatted Time Packet
Formatted Time Packet
Packet ID
22
Length
14
Read / Write
Read
Field #
Bytes Offset
Data Type
Size
Description
1
0
u32
4
Microseconds
2
4
u16
2
Year
3
6
u16
2
Year day, 0 - 365
4
8
u8
1
Month, 0 - 11
5
9
u8
1
Month Day, 1 - 31
6
10
u8
1
Week Day, 0 – 6 (0 = Sunday)
7
11
u8
1
Hour, 0 - 23
8
12
u8
1
Minute, 0 - 59
9
13
u8
1
Second, 0 - 59
Table 64: Formatted Time Packet