Advanced Illumination MicroBrite Series Скачать руководство пользователя страница 2

2

DF198

Released 7/15/2015

Updated 5/2/2016

DF198-050
DF198-115
DF198-180
DF198-280

(A)

Outer

Diameter

(B)

Inner

Diameter

50.0 (1.97)

(C)

Housing

Thickness

18.3 (0.72)

16.6 (0.66)

113.3 (4.46)

74.9 (2.95)

19.3 (0.76)

179.9 (7.09) 141.9 (5.59)

18.2 (0.72)

280.0 (11.02) 241.4 (9.50)

18.2 (0.72)

Part 

Number

Model

Size

in mm

Spectral 

Wavelength

Connector/

Control

Alternative 

Connector

DF198

XXX

XX

XXX

XXX

DF198

050
115
180
280

455 (blue)
530 (green)
625 (red)
WHI (white)
RGB

C1
C5

IC

I3

I3S

24

M12

DF198-100WHII3

DF198-180625C1

Ex: 

Available with IC, I3, I3S and 24v options only

The 24v version will have a lower output intensity by ~10-15% 

and operate at a temp ~10-15% higher than other options

Available with C1 option only

Not available with 24v option

1

1

2

2

3

3

4

4

Mechanical Specifi cations

Part Number Key

C1 Connector

For use with:

DCS Series

Controllers

C5 Connector

For use with:

Pulsar 320 Strobe

Controller.

IC

Continous in-line 

controller

Powered with:

24V power supply

I3 

Combination 

strobe/continous 

in-line controller

Powered with:

24V power supply

Build to Order:

shipped in two weeks

DF198-100WHII3

Stock Product:

shipped next day

Connector | Control Options

I3S 

Default-OFF

strobe/continous 

in-line controller

Powered with:

24V power supply

24

Flying/tinned leads

Powered with:

24V power supply

Содержание MicroBrite Series

Страница 1: ...en Maintenance Electrical Specifications Unavailable IP40 Group 1 Low Risk Applicable Wavelengths 455 530 625 WHI Color 24v Current A All Other Controls A Max Part Number 625 n a 0 13 WHI n a 0 22 455 n a 0 22 530 n a 0 22 625 0 7 0 32 WHI 0 7 0 54 455 0 7 0 54 530 0 7 0 54 625 1 4 0 64 WHI 1 4 1 08 455 1 4 1 08 530 1 4 1 08 625 1 6 0 74 WHI 1 6 1 24 455 1 6 1 24 530 1 6 1 24 DF198 050 DF198 115 DF...

Страница 2: ...ions only The 24v version will have a lower output intensity by 10 15 and operate at a temp 10 15 higher than other options Available with C1 option only Not available with 24v option 1 1 2 2 3 3 4 4 Mechanical Specifications Part Number Key C1 Connector For use with DCS Series Controllers C5 Connector For use with Pulsar 320 Strobe Controller IC Continous in line controller Powered with 24V power ...

Страница 3: ...kLux Min 30 6 Typ 36 1 Irradiance W M Min 110 5 Typ 130 0 Illuminance kLux Min 39 9 Typ 47 0 Optical Performance Working Distance mm Irradiance klux Illuminance W m2 Part Number 12 7 703 223 300 4 2 1 5 50 94 2 32 7 100 42 6 14 6 300 5 9 2 1 64 130 47 100 103 3 36 1 300 20 3 7 100 62 5 22 7 200 41 4 14 5 300 23 8 8 2 DF198 180 DF198 280 DF198 115 DF198 050 FWHM Diameter mm 33 0 100 37 2 12 3 83 8 ...

Страница 4: ...in workmanship and materials for a period of two years from the original date of purchase Should a defect develop during this period please contact Ai Customer Service or your Ai distributor for a Return Merchandise Authorization RMA and return the complete product freight prepaid to Ai If a defect is found Ai will at our discretion repair or replace the product without charge Ai claims no liabili...

Страница 5: ...y through Friday 8 00 am to 5 00 pm ET or send an email to orders advill com Customer Service Company Information Advanced Illumination Email info advancedillumination com Web advancedillumination com 2015 Advanced Illumination Inc All rights reserved 440 State Garage Road Rochester VT 05767 Phone 802 767 3830 Fax 802 767 3831 ...

Отзывы: