17
18
Before charging:
Only add distilled water. If fluid is below
the top of the plates, add just enough to
cover plates.
After charging:
Check that the fluid level is appropriately
1/4 to 1/2 inch above the plates and 1/4 to
3/8 inch below the level is low. Add
distilled water carefully. Adding distilled
water after charging helps prevent boiling
over.
A Battery cap
B Plates
C Maximum fluid level
D Minimum fluid level
Note: Only lead-acid batteries
need to add battery water,
maintenance-free batteries do not
need.
Normal tap water contains minerals
which are harmful to a battery;
therefore, refill only with distilled water.
3. Using a hydrometer, check the specific
gravity of the battery fluid in each cell
against the readings on the chart below.
Consult an AdvancedEV dealer if any low
readings are found.
Satisfactory liquid
densimeter
When installing the batteries, do not
put the wrenches or other metal
objects across the battery terminals.
An arc occur causing explosion of
batteries.
Do not disconnect the DC output
cord from the battery receptacle
when the charger is on because that
may cause an explosion.
3. The charger will turn off automatically
when the batteries reach full charge.
4. After the charger has turned off
disconnect the DC output plug from the
golf car receptacle by grasping the plug
body and pulling the plug straight out of
the receptacle.
Maintenance
Maintenance
Содержание ADVENT 2