Table 3‑12. Climatic specifications
Temperature
Relative Humidity
Air Pressure
Operating
Self cooled models:
+0°C to +45°C
+32°F to +113°F
Force cooled models:
+0°C to +35°C
+32°F to +95°F
5% to 85%
[1]
1 g/m
3
to 25 g/m
3
1 g/m
3
to 25 g/m
3
78.8 kPa to 106 kPa
788 mbar to 1060
mbar
Equivalent altitude:
+2000 m to -500 m
(+6562′ to -1640′)
Storage
-25°C to +55°C
-13°F to +131°F
5% to 95%
1 g/m
3
to 29 g/m
3
78.8 kPa to 106 kPa
788 mbar to 1060
mbar
Equivalent altitude:
+2000 m to -500 m
(+6562′ to -1640′)
Transportation
-25°C to +70°C
-13°F to +158°F
95%
[2]
60 g/m
3
[3]
65.6 kPa to 106 kPa
656 mbar to 1060
mbar
Equivalent altitude:
+3500 m to -500 m
(+11480′ to -1640′)
Non-condensing, no formation of ice
Maximum relative humidity when the unit temperature slowly increases, or when the unit temperature
directly increases from -25°C to +30°C (-13°F to +30°F)
Maximum absolute humidity when the unit temperature directly decreases from +70°C to +15°C
TYPE DESIGNATION
The type designations of the Thyro-PX power controllers are derived from the
construction of its power section, as shown in the following table.
Table 3‑13. Type designation
Type Range
Designation
Features
Thyro-PX
power
controller
1PX
1-phase power section, for 1-phase operation
Advanced Energy
®
Thyro-PX® Power Controller
57010148-00B
Specifications