OPERATING INSTRUCTIONS & GENERAL INFORMATION

 

INTRODUCTION

 

Advanced  Amplifiers  is  an  amplifier  equipment  and  services  company  supporting  commercial  and  government 
organizations worldwide. 

 

Headquartered in San Diego, California, the company utilizes its global network of resources to effectively serve 
and support customer requirements. 

 

As  a  unique  original  equipment  manufacturer  of  power  amplifiers  ranging  from  10KHz  to  40GHz  with  various 
output  power  levels  for  CW  &  pulse  testing  applications,  we  can  also  fully  support  custom  designs  and 
manufacturing  requirements  for  both  small  and  large  volume  procurements.  We  bring  decades  of  combined 
experience in the RF field for numerous applications including and not limited to, EMI/EMC, communications, and 
various commercial and industry standards. 

 

With our in-house capabilities and fully equipped testing facilities, Advanced Amplifiers is committed to provide 
the best in RF products with industry leading quality and lead times.

 

INCOMING INSPECTION

 

Inspect unit for any sign of external damage. Do not use this equipment if there is physical damage or missing parts. 
Inspect all front and rear panel connectors for damage. Inspect fans and their airways for any damage or blockings. 
For a unit with a digital controller option, the USB and ethernet interface and commands list is in the second part 
of the manual.

 

RF & AC CABLE CONNECTION

 

RF  Input  and  Output  connectors  are  outlined  in  the  specifications  table.  Use  the  standard  AC  cable  that  was 
supplied by the manufacturer or higher power rating cables than the manual specifies. Refer to the front and rear 
panel description page for the location of RF and AC connectors.

 

For a system with a digital controller option  – DO NOT USE OR CONNECT a PoE enabled ethernet switch to a 
system. Our digital controller does not support PoE connection and will cause permanent damages to a controller 
unit. 

RF TURN ON PROCEDURE

 

Connect RF input to an RF generator. Connect a suitable load for the power rated and continuous operation to the 
output  connector.    Turn on the AC switch, display will  show STANDBY. Optionally,  connect  the  unit  to  a  digital 
control Software or Ethernet connection.    Set the RF generator to nominal 0dBm and set the desired frequency 
in the specified range. Select Gain or ALC and set to the desirable output power level then press the ONLINE button. 
Use the front panel LCD gain adjust or the remote function to adjust the output power on the power meter and 
the LCD screen to desired levels.

 

Refer to Appendix1 for detailed operating instructions of the local and remote controller.

 

RF TURN OFF PROCEDURE

 

Decrease the RF drive from the RF generator to below -20dBm and press STANDBY on the LCD or via the control 
software. Turn off AC switch on the front panel. Disconnect any unnecessary cable connections.

 

Содержание AA-10K250M-150

Страница 1: ...1 P a g e Ver 1 0 Instruction Manual Including Quick Start Guide Advanced Amplifiers Solid State RF Amplifier System AA 10K250M 150 10 KHz 250 MHz 150 Watt 52 dB Min...

Страница 2: ...ECHANICAL SPECIFICATIONS 4 OPERATING INSTRUCTIONS GENERAL INFORMATION 5 INTRODUCTION 5 INCOMING INSPECTION 5 RF AC CABLE CONNECTION 5 RF TURN ON PROCEDURE 5 RF TURN OFF PROCEDURE 5 DECLARATION OF CE C...

Страница 3: ...ing the output load or other components The main power source to the equipment must have an uninterrupted safety ground that has sufficient size to the power cord REPAIR MAINTENANCE All repair or main...

Страница 4: ...asic units 10 Sec without damage 2 Units with optional digital monitor and control for basic units 1 minute at rated Pout ENVIRONMENTAL CHARACTERISTICS Parameter Specification Notes Operating Ambient...

Страница 5: ...nterface and commands list is in the second part of the manual RF AC CABLE CONNECTION RF Input and Output connectors are outlined in the specifications table Use the standard AC cable that was supplie...

Страница 6: ...replacement of defective goods F O B factory of which Seller is modified in writing by Buyer within three 3 years following delivery thereof to Buyer and in no event will Seller be liable for incident...

Страница 7: ...VIEW No Title Function 1 RF INPUT N Female RF INPUT Connector 2 RF Sample N Female RF SAMPLE Connector 3 FAULT LED System Fault LED Turn ON an LED when System Fault Over Input Over Temp Over Current...

Страница 8: ...DEBUG System Controller Debugging Female Connector Customer should not use this port without permission from the factory 5 USB USB Communication Connector Type A Female 6 ETHERNET Ethernet Communicati...

Страница 9: ...9 P a g e Ver 1 0 SYSTEM OUTLINE VIEW...

Отзывы: