The operating time may also need to be changed at any time in the future to accommodate a different 
type or specifi c weight of the fuel used.
When the fuel level inside the motorized warehouse decreases, the sensor located inside it (see Figure 
2) will stop the engine operation, leaving the transport system in standby mode, as soon as the correct 
fuel level is restored, the system will restart automatically.

10.1 Minimum level sensor calibration

The sensitivity of the minimum fuel level sensor is already calibrated, but if a new calibration is needed, proceed 
as follows (see Figure 7):
• Place the sensor in front of the surface to be detected (pellets).
• Use a screwdriver with a max diameter of 3 mm.
• Rotate the potentiometer clockwise or counterclockwise for 2/3 turns until it reaches the correct activation point 

(LED on).

• If turning the potentiometer the LED lights up immediately, turn it counterclockwise for about 45° and then turn it 

clockwise again until it reaches the point of activation (LED on).

fi gure 5

+

-

LED

fi gure 6

fi gure 7

10.2 Operational safety

There is a safety that guarantees the correct functioning of the tank, this safety acts every time for three consecutive 
engine operating cycles, fuel is not sucked and therefore the dispenser remains empty. 
In this case, the security interrupts the operation which is not automatically restored.
The causes of malfunction can be various, including the following:
A) lack of fuel inside the tank
B) A fuel clog has formed in the pipeline between the tank and the dispenser.
C) Pipes are not intact or there are air leaks in their fi ttings
D) The fi lter inside the dispenser is blocked
E) The dispenser exhaust door is not tightly closed during suction.
When the cause of the blockage has been removed, the light switch must be switched off for at least 3 seconds and 
then turned on again (light on).
If the problem occurs frequently, it is advisable to contact the service centre.

Содержание M-TANK

Страница 1: ...27 ASSEMBLY USE AND MAINTENANCE MANUAL Motorized Tank M TANK...

Страница 2: ......

Страница 3: ...te 6 3 2 Safety symbols 6 4 PACKAGING CONTENT 7 5 INSTALLER S RESPONSIBILITIES 7 6 PROPER USE OF THE PRODUCT 7 7 INSTALLATION 8 8 PIPES CONNECTION 8 9 ELECTRICAL CONNECTION 9 10 START UP AND USE 9 10...

Страница 4: ...ons to this manual and to the equipment at any time without obligation to advise third parties 2 WARNINGS Do not use the machine for any improper use Do not let children near the machine This unit mus...

Страница 5: ...ac 230 Frequency Hz 50 Motor power W 1350 Max absorp onx A 5 8 Thermal switch A 8 Fuse T16A5x20 Weight Kg 32 40 Net volume l 199 330 Content max kg Net volume x 0 8 Pipe mm 50 50 Maximum air flow m3...

Страница 6: ...of serious personal injuries During maintenance operations always disconnect the power supply and make sure that it cannot be restored DANGER OF CUTTING Danger of serious personal injuries During main...

Страница 7: ...it is necessary to add two 50 mm rigid steel pipes or antistatic flexible hoses are sufficient one for transporting the fuel and one for the return air and a dispenser installed on the boiler tank for...

Страница 8: ...inserting it into the hole on the side of the storage unit inserting the sealing gasket see figure 6 Also install the four adjustable feet in their respective threaded inserts on the bottom of the wa...

Страница 9: ...to it properly the electrical connections are correctly and permanently fixed the led of the minimum level sensor is switched on the power supply is correct and stable the exhaust door of the dispens...

Страница 10: ...ometer the LED lights up immediately turn it counterclockwise for about 45 and then turn it clockwise again until it reaches the point of activation LED on figure 5 LED figure 6 figure 7 10 2 Operatio...

Страница 11: ...vent excessive dust deposits cleaning the motor ventilation grides with compressed air Using fuels with a low presence of dust guarantees a better functioning of the motorized tank 11 1 End of life Th...

Страница 12: ...4 weeks after the fuel filling enter only with a CO detector Aerate the storage room for at least 15 minutes before entering and keep the door open during your permanence Ensure an adequate and perman...

Страница 13: ...se misapplication repair alteration or unauthorized disassembly 2 maintenance operation use which is not in accordance with the product instructions or connection to an improper voltage supply or 3 us...

Страница 14: ...EC 1907 2006 REACH or registration evaluation authorization and restric tion of chemical substances Although in the working cycles of raw materials and our products such substances are not used their...

Страница 15: ...15 English 15 12 21 Rev 1 0 1...

Страница 16: ...M TANK F0920593 03 info advanceeasymoving com www advanceeasymoving com...

Отзывы: