Universal system instruction manual

125/10/21  Rev:1.0.1

18

When you want to fi ll the tank, proceed as follows:
a) 

set the illuminated switch on the control panel to 1 and check that the switch lights up

b) 

open the suction inlet fl ap and insert the fl exible hose equipped with a lance

c) 

c) when the system starts the suction cycles, position the lance in the bag or in any other 
container of the fuel to be aspirated. The suction lance must never be completely immersed 
in the fuel to be sucked, the fl uidization grille placed in the front of the lance must always be 
left free to suck air (see fi gure 27)

d) 

topping up can be interrupted at any time simply by lifting the lance from the fuel and 
extracting the fl exible pipe from the suction inlet. Regardless, when the tank is full, the 
suction cycles are interrupted automatically.

e) 

at the end of the operation, disconnect the fl exible pipe from the suction inlet and make sure 
that the inlet fl ap is properly closed. In this way the system stops functioning.

f) 

if you do not intend to use the system for a long period, set the illuminated switch on the 
control panel back to 0. 

13 CORRECT USE OF THE SYSTEM

Figure 27

Now check that the duration of each suction cycle is long enough to fi ll the dispenser tank with the right 
amount of fuel, at least up to half of its internal volume.
To make this check at the end of a suction cycle, keep the outlet door closed after completing a cycle 
and turn off the system, then open the lid of the dispenser tank and check the contents.
Now use the trimmer located in the center of the control panel to change the time of the suction 
cycles, at each click the time of the suction cycle changes by 2 seconds. Turning it clockwise with a 
small screwdriver will lengthen the time and bring more fuel in the metering unit, vice versa, turning it 
anticlockwise with each click, the time will shorten by 2 seconds and less fuel will be brought into the 
metering unit.
There are 16 trimmer positions and they regulate the time of the suction cycles from 2 to 32 seconds. 
The 0 seconds position is not present.
To completely fi ll the tank, continue holding the lance on the bulk fuel, until the operating cycles stop 
automatically on their own.
The operating cycles cease when there is such a quantity of fuel in the tank that the lower door of the 
dispenser tank is not closed.
At the end of the operation, always disconnect the fl exible hose from the wall inlet and make sure that 
the inlet fl ap closes properly.

Содержание FIREPOD universal

Страница 1: ...SYSTEM FIRE POD UNIVERSAL ASSEMBLY USE AND MAINTENANCE MANUAL 26 ...

Страница 2: ......

Страница 3: ...d compartments with controlled pressure 11 7 4 Motor 11 7 5 Suction inlet 12 7 6 Antistatic flexible piping Ø 45 mm 12 7 7 Flexible pipe with suction lance 13 7 8 electrical connection cables 14 8 ACCESSORIES OPTIONAL 14 8 1 Minimum level sensor for tank 14 8 2 Air exhaust silencer 15 8 3 Dust separator filters 15 8 4 Antistatic PU flexible pipe Ø 45 mm 15 8 5 Sleeve Ø 45 mm for joints 15 8 6 Adju...

Страница 4: ...efully for the entire operating life of the product The main objective of this manual is to familiarise the product and its correct safe use No part of this manual may be reproduced or copied without the written authorisation of the manufacturer The manufacturer reserves the right to make improvements and modifications to this manual and to the product itself without having the obligation to notif...

Страница 5: ...x humidity level 30 95 Supply V ac 230 Frequency Hz 50 Motor power kW 1 35 Absorption A 5 8 Thermal circuit breaker A 8 Max dosing capacity l 6 dispenser tank weight kg 2 2 Control panel weight kg 0 45 Motor weight kg 1 8 Motor plate weight kg 0 55 Weight of complete suction inlet kg 0 15 Weight of antistatic hose kg m 0 35 Weight of connection cables kg m 0 15 Noise dB A 70 N B Nominal noise valu...

Страница 6: ... VOLTAGE OR ELECTRIC CURRENT Danger of serious personal injury During maintenance operations disconnect the electricity and make sure that the power supply cannot be restored CUTTING HAZARD Danger of serious personal injury During maintenance operations disconnect the electricity and ensure that the power supply cannot be restored AUTOMATIC STARTING HAZARD Danger of serious personal injury During ...

Страница 7: ...10 1 x cable for control panel power supply 11 1 x cable for suction inlet control panel connection 12 5 x metal hose clamps 13 4 x TCC5x12SP screws for fixing the motor plate 14 1 x guarantee form 15 1 x assembly use and maintenance manual Check that the control unit its accessories and the kit correspond to what was ordered and that they do not show obvious signs of transport damage If this is n...

Страница 8: ...atically It stops by itself when the fuel inside the tank prevents the discharge door from closing doser see point 6 2 Its components can also be installed inside the furnishings that integrate inserts and fireplaces aesthetically provided they remain accessible for maintenance purposes The system cannot vacuum products with too fine 2mm or too large 10mm granulometry or excessively dusty damp and...

Страница 9: ...9 English 20 10 21 Rev 1 0 1 1 2 3 4 5 6 7 8 9 IN OUT OUT IN ...

Страница 10: ...2 to 32 seconds see figure 1 The panel must be permanently fixed by its anchor points see figure 2 away from sources of excessive heat and protected from water Figure 1 Figure 2 0 1 7 2 Dispenser tank The dispenser tank must be permanently fixed by its anchor points see figure 3 above the fuel tank taking care that it is perfectly level Alternatively the multiposition shelf optional can be used Wh...

Страница 11: ... and the rubber plate do not compromise the proper functioning of the transport system instead they could change the internal pressure of the tank or that of the compartment where the chimney is installed compromising its safety It is possible to solve this problem mainly by programming the working time of the fuel transfer system only when A The brazier of the boiler is switched off and cold B Th...

Страница 12: ...flexible see figure 24 made of thick polyurethane and is equipped with a copper strand It should be cut to size to connect the various components of the system The maximum recommended lengths for connecting the various system components are as follows 2 5 meters from the suction inlet to the dispenser tank max 3 30 m 2 meters from the doser to the motor max 3 m 1 5 meters from the motor to the air...

Страница 13: ...th suction lance This 1 5 meter pipe must be assembled by screwing in the rubber fitting that will support the steel lance to one end see figure 12 on the other end screwing in the fitting that will be used for the connection in the suction inlet see figure 13 The hose will only be connected to the suction socket before each loading operation and dis connected once completed see figure 14 Figure 1...

Страница 14: ...ee figure 20 the red LED lights up to indicate that the minimum fuel level in the tank has been reached 7 8 Electrical connection cables The electric cables supplied are all equipped with different wiring to avoid positioning errors The cables allow the connection of power supply to the control panel see figure 15 and the connection of the suc tion inlet to the control panel see figure 16 The othe...

Страница 15: ...lter has a fixed wall mounting see figure 22 and another smaller lighter model with handles and feet see figure 23 can be positioned more easily on the ground or on a shelf also just during loading operations 8 4 Antistatic PU flexible hose Ø 45 mm The 6 m length hose see figure 24 it can be useful if the distances to be covered between the various components of the system are greater than the sta...

Страница 16: ...onnection points are fastened with steel hose clamps and that there are no cracks or air leaks Any junctions must be made using the specially designed rubber sleeves optional The different hose sections must be firmly fastened to a wall or to a stable surface and must have no dips or excessive bends Any bends must have a minimum radius of 50 cm Keep the hoses away from heat sources like funnels co...

Страница 17: ... the control panel to 1 and check that the switch lights up open the suction inlet flap and insert the flexible pipe equipped with lance The system will now start operating with 2 second suction cycles and short consecutive repetitive shutdowns the shutdown phases allow the fuel to be discharged from the metering unit into the tank After a few empty cycles you can start sucking the fuel by placing...

Страница 18: ... THE SYSTEM Figure 27 Now check that the duration of each suction cycle is long enough to fill the dispenser tank with the right amount of fuel at least up to half of its internal volume To make this check at the end of a suction cycle keep the outlet door closed after completing a cycle and turn off the system then open the lid of the dispenser tank and check the contents Now use the trimmer loca...

Страница 19: ... which can be reached by opening the lid using the two hooks positioned on both sides see figure 29 Blow the motor ventilation grids annually with low pressure compressed air to eliminate any dust deposits To ensure the optimum and long lasting operation of the system in the event of breakdowns it is recommended to contact an authorized service center and to use only original spare parts 14 1 End ...

Страница 20: ... is not perfectly closed the micro switch of the suction inlet does not work Suction does not work the lower dispenser tank discharge flap is open the micro switch of the doser does not work the switch light 0 1 is off and therefore there is no power supply to the system the thermal circuit breaker has tripped The thermal breaker 8 A thermal switch positioned on the control panel see figure 28 has...

Страница 21: ...om 1 accident abuse misapplication repair alteration or unauthorized disassembly 2 maintenance operation use which is not in accordance with the product instructions or connection to an improper voltage supply or 3 use of consumables and spare parts which are not supplied by the manufacturer or authorized service center Valid warranty claims are generally processed through the point of purchase of...

Страница 22: ...th Regulation EC 1907 2006 REACH or registration evaluation authorization and restriction of chemical substances Although in the working cycles of raw materials and our products such substances are not used their presence in the size of p p m parts per million cannot be excluded due to micro pollution of raw materials Declaration of conformity The Manufacturer declares that its products and equipm...

Страница 23: ......

Страница 24: ...FIRE POD F0920593 info advanceeasymoving com www advanceeasymoving com ...

Отзывы: