CONNECTION: 

 

                   

 

 

Must be installed by a competent person. 

 

Disconnect power source. 

 

Cover or shied any adjacent live components. 

 

Ensure device cannot be switched on. 

 

Check power supply is disconnected. 

 

 

Twist the cover in an anti-clockwise direction to remove. 

 

Connect  the  power  and  the  load  according  to  the  wiring 

diagram. 

 

Fix the sensor to the surface as required. 

 

Twist and lock the cover back into position, turn on the power 

and check the sensor functionality. 

 

WIRING DIAGRAM 

(See the below image) 

 

 

 

 

 

 

 

 

 

SENSOR INFORMATION: 

 

 

 

 

 

 

 

TEST:

 

 

  Turn the TIME knob anti-clockwise to the minimum (-). 

Turn the LUX knob clockwise to the maximum (sun). 

  Switch  on  the  power;  the  sensor  and  its  connected 

lamp will have no signal at the beginning. After a 30sec 

warm-up  period,  the  sensor  will  be  operational.  If  the 

sensor detects movement, the load will turn on. When 

no further movement is detected, the load should switch off within 10sec

±

3sec. 

 

Turn LUX knob anti-clockwise to the minimum (3). If the ambient light is more than 3LUX, the 

sensor will switch the load off. If the ambient light is less than 3LUX (darkness), the sensor will 

switch on the load. With no occupancy detected, the sensor will stop working within 10sec

±

3sec. 

Note:  when  testing  in  daylight,  please  turn  LUX  knob  to          (SUN)  position,  otherwise  the 

sensor may not work!   

 

TROUBLESHOOTING: 

 

The load does not work: 

a. Please check if the connection of power source and load is correct. 

b. Please check if the load is operational 

c. Please check the light level setting. 

 

The sensitivity is poor: 

a. Please check if the sensor is obstructed from detecting movement. 

b. Please check if the ambient temperature is too high. 

c. Please check if the movement is in the detection field. 

d.  Please  check  if  the  installation  height  corresponds  to  the  height  required  in  the 

instruction. 

 

The sensor does not turn off the load automatically: 

a. Please check if there is continual movement in the detection field. 

b. Please check if the time delay is set to the maximum duration 

c. Please check if the wiring corresponds to the instruction. 

Height of installation:2.2-4m 