Chapter 5 Installing Shelves
Installation and Commissioning Manual
139
F
S
P
3000R
7 R
11
.1 8000
0015930
Issue
B
, ©
2012
ADVA AG Optical Netw
orking
ADVA Conf
idential
Step 5
Fit the appropriate ETSI or NEBS bracket to the shelf.
a) Place the appropriate bracket on the same side of the shelf in the
correct position as illustrated in
and
three threaded holes in the shelf side panel and the holes of the
bracket should line up.
b) Reinsert the two fixing screws M5x8 and the screw M5x6 into the
corresponding threaded holes.
c) Secure the bracket to the shelf by tightening the screws with a
Torx screwdriver TX20.
d) If you have attached a Front NEBS bracket, mount the appropriate
steel stiffener as shown in
Use the screw M5x6. Secure the steel stiffener to the shelf by
tightening the screw with a Torx screwdriver TX25.
Figure 19:
Fitting the ETSI and NEBS Adopter Brackets to an SH1HU-R/PF Shelf
Step 6
Save the 19-inch bracket with the packaging material.
Step 7
Repeat
to
for the opposite side.
End of Procedure
P
S
Note
Be sure to attach the steel stiffeners when fitting the front NEBS
brackets.Use the screw M5x6 supplied by ADVA Optical Networking.
Steel stiffener,
left
Front NEBS bracket,
left
ETSI bracket,
left
ETSI bracket,
right
19-inch
bracket, right
19-inch
bracket, left
1 x screw M5x6 and 2 x M5x8
per bracket
Steel stiffener, right
Front NEBS bracket, right