background image

64179008APL1-5A

19

The LIU Configuration Menu allows the user to view
general information about the unit including unit
name, part number, CLEI code, and revision numbers.
The LIU Configuration menu is a read-only menu that
is only updated when new software revisions are
installed.

The LIU Provisioning Menu allows the user to view
and make changes to options concerning each HDSL2
port.  The LIU Provisioning Menu provides an NIU
Loopback sub-menu, a Loopback Timeout sub-menu,
and a Framing Mode sub-menu.  The NIU Loopback
sub-menu allows the user to enable or disable each
loop’s response to loopback codes.  The first screen
that is shown is for Loop 1.  Other Loops may be
accessed by using N for next and P for the previous
Loop.   When NIU Loopback is Enabled, the unit will
accept and act upon loopback codes sent from the
network.  When NIU Loopback is Disabled, loopback
codes are ignored.  The Loopback Time Out submenu
allows the user to set a Loopback Time Out for each
port.  The Loopback Time Out may be set to None, 20
Minutes, 60 Minutes, or 120 Minutes and dictates the
maximum time that a circuit may remain in the
loopback condition.  The Framing Mode submenu
allows the user to choose between SuperFrame (SF)
and Extended SuperFrame (ESF) framing for each
HDSL2 Port.

The LIU Span Status Menu provides the user to with
statistics vital to successful operation of the Total
Access 1000 DAT.  This menu provides signal quality
statistics in terms of Margin (current/minimum/
maximum) for each HDSL2 loop.  Attenuation
(current/maximum), Errored Seconds (ES), Severely
Errored Seconds (SES), and Unavailable Seconds
(UAS) for the last 15-minute interval are also revealed
on the LIU Span Status screen.  An example of the
LIU Span Status screen is shown in 

Figure 18

.

The LIU Test Menu allows the user to invoke a
Network Loopback for each individual port or a
Backplane Loopback, which puts a Line Loopback on
all ports at once.

Figure 18.  LIU Span Status Screen

Total Access 1000 (ATM)

                          HDSL2 Quad LIU Span Status

                                               H2TU-R
                                Loop 1    Loop 2    Loop 3    Loop 4
                               --------  --------  -------  ---------
          MARGIN(CUR/MIN/MAX): 16/00/17  17/00/17  17/00/17  17/00/17
               ATTEN(CUR/MAX):  00/01     00/01     01/02     00/01
                           ES:   000       000       000       000
                          SES:   000       000       000       000
                          UAS:   000       000       000       000

                           1. Zero Registers
                           2. Restart Min/Max

                             Selection :

Содержание Total Access 1000

Страница 1: ...ce Monitoring Statistics 20 Figure 20 Quad ADSL Status Screen 21 Figure 21 Quad ADSL Circuit Overview Screen 22 Figure 22 H2LIU Network Loopback 23 Figure 23 HDSL2 Deployment Guidelines 23 Trademarks...

Страница 2: ...Quad H2LIU module provides the network interface for the Total Access 1000 DAT The H2LIU terminates three or four HDSL2 signals from the network and passes span powering to the PSU The PSU terminates...

Страница 3: ...the HDSL2 spans and requires at least three spans of HDSL2 for proper operation WARNING Risk of electric shock Voltages up to 190 VDC may be present on telecommunications circuit Alwaysensurethatthef...

Страница 4: ...ules consist of the PSU Quad H2LIU and ATM BCU These modules are needed to power up the shelf and to provide the needed ATM switching fabric for the system The Access Modules consist of Quad SHDSL Qua...

Страница 5: ...h the ADSL on one single pair The customer premises must be equipped with an ADSL plus POTS splitter for the POTS signal to the telephone and the proper Customer Premise Equipment CPE to terminate ADS...

Страница 6: ...it is a common module plug in unit See Figure 8 The unit inserts directly into the BCU slot on the Total Access 1000 DAT shelf The unit terminates the ATM DS1 IMA from the H2LIU and provides distribut...

Страница 7: ...he Total Access 1000 DAT enclosure contains brackets that support wall pole or pedestal mounting Tools Needed Wall Mount or Polemount The Total Access 1000 DAT Chassis mounts and connects with standar...

Страница 8: ...connected to certain pairs on the Total Access 1000 DAT termination block The ADSL plus POTS signal is then delivered to the customer by other pairs on the termination block See Table 2 for pair assi...

Страница 9: ...SU front panel contains a POWER LED indicator The POWER LED is ON when the proper power is being received from the HDSL2 pairs and is being distributed properly to the other modules in the chassis Tab...

Страница 10: ...ng a standard male to female RS 232 DB 9 cable Craft port settings are as follows 9600 Baud No parity 8 Data bits 1 Stop bit CAUTION TheATMBCUretainsprovisioningsetupwhen removedfromthechassis Ifinser...

Страница 11: ...eight minutes of keyboard inactivity If this happens during provisioning simply logon to the system again and continue from the last completed provisioning change Menu Navigation To traverse through t...

Страница 12: ...rce All Facilities Into Unassigned 2 Force Facility 0 Init Pass Through PHY 0 3 Force Facilities Into IMA Group 1 In Service 5 IMA Scrambler 1 Enable 2 Disable 6 Restore Factory Defaults 2 IP Address...

Страница 13: ...ATM ports and IMA Facilities The Circuit Management menu has four sub menus including the following ATM Port Provisioning ATM PVC PVP Management ATM Traffic Parameter Defaults IMA The ATM Port Manage...

Страница 14: ...irections Traffic Type PCR 0 PCR 0 1 SCR 0 SCR 0 1 MBS 0 MBS 0 1 Tagging Pkt Discard UBR N A Best Eff N A N A N A N A N A Yes CBR N A 0 N A N A N A N A No Yes VBR rt N A 0 N A 0 N A 0 No Yes VBR nrt N...

Страница 15: ...1 unassign all facilities or put each facility in pass through The IMA Provisioning menu also allows the user to enable or disable scrambling on the IMA signal This option must match the setting on th...

Страница 16: ...ach IMA link individually All the options provisionable under the IMA Provisioning menu may be set to the factory default settings by choosing the option corresponding to Restore Factory Defaults on t...

Страница 17: ...nk 3 NE Tx State Active Active Active Status Active NE Rx State Active Active Active Active FE Tx State Active Active Active Active FE Rx State Active Active Active Active NE Rx Failure No Failure No...

Страница 18: ...band Telnet The Time Date sub menu allows the user to set the date and time The date in entered in a MM DD YY format and the time is entered in a 24hr clock manner The Baud Rate sub menu allows the us...

Страница 19: ...None 20 Minutes 60 Minutes or 120 Minutes and dictates the maximum time that a circuit may remain in the loopback condition The Framing Mode submenu allows the user to choose between SuperFrame SF and...

Страница 20: ...appropriate Access Module The Quad ADSL plus POTS Access Module provides the following menus Configuration Provisioning Status Alarms Performance ATM Loopback The ADSL Configuration Menu allows the u...

Страница 21: ...tion resets all of the provisioning options for the ADSL Access Module to the default settings The ADSL Status Menu provides status information for each ADSL port Three sub menus including ADSL Status...

Страница 22: ...ccess 1000 DAT The Configuration Prompt may be used to download provisioning scripts so that no manual provisioning is needed The Configuration Prompt also allows the user to save a configuration to a...

Страница 23: ...ged taps in kft This deployment criteria is summarized in the chart shown in Figure 23 DSX 1 H2TU C Local Loop HLIU Network Side Loopback and or HLIU NIU Loopback H2LIU X DS1 AIS X Signal Inactive Fig...

Страница 24: ...551 1 587 1 634 19 Pulp 1 817 1 856 1 909 Table 6 HDSL2 Loss Values 200 kHz cable loss in dB kft at 135 Frequency Hz Maximum Loss dB 3 000 12 0 10 000 15 0 50 000 25 5 100 000 30 0 150 000 32 75 200...

Страница 25: ...ent 414 Enterprise Networks Warranty Document 901 Contact Customer and Product Service CAPS prior to returning equipment to ADTRAN Refer to the following subsections for service CAPS requests or furth...

Страница 26: ...26 64179008APL1 5A...

Страница 27: ...the template holes to identify where the pilot holes will be drilled Using a 1 16 inch bit drill pilot holes at the marked locations Mount the chassis using the six 6 by 3 4 inch flat head wood screws...

Страница 28: ...edge Align the card edges to the guide grooves and insert the unit until the edge connector seats firmly into the backplane Lock the card in place by pushing in the locking lever in against the front...

Страница 29: ...0 DAT must be changed to match the upstream IMA device To change any of these options on the ATM BCU enter the IMA Menu select Provisioning select Shortcut Setup select Force All Facilities into Unass...

Страница 30: ...VBR nrt is chosen continue with the next step 21 Use the right arrow key to highlight the traffic descriptor fields When each field is highlighted a description of the field is displayed at the botto...

Отзывы: