ADTRAN TSU CSU ACE 1202022L1 Скачать руководство пользователя страница 2

TSU CSU ACE

P/N 1202022L1

Quick Start Guide, 61202022L1-13A, September 2001

Technical Support 1-888-4ADTRAN (1-888-423-8726)

Copyright 

 2001 ADTRAN, All Rights Reserved

N

ETWORK

 LBO S

WITCH

 P

OSITION

 S

ETTINGS

Position 1

Position 2

Attenuation (dB)

On

On

0

On

Off

7.5

Off

On

15

Off

Off

22.5

CPE LBO S

WITCH

 P

OSITION

 S

ETTINGS

Position 3

Position 4

Position 5

Cable Length (feet)

Off

Off

On

0-133

On

On

Off

134-265

Off

On

Off

266-399

On

Off

Off

400-533

Off

Off

Off

534-655

T

EST

 

AND

 M

ONITOR

 A

CCESS

Two monitor jacks are provided on the rear panel for bridging the 
received signals to allow in service circuit monitoring.

Four break-and-test jacks are provided on the rear panel for use in out-
of-service testing. These jacks bypass the connections of the modular 
jacks. N

ET

 I

N

 and N

ET

 O

UT

 are used to simulate the network input and 

output of the TSU CSU ACE. To test the CPE, a T1 Bit Error Rate Test 
(BERT) test set can be used to simulate the network. E

Q

 I

N

 and E

Q

 O

UT

 

can be used to simulate the CPE with a BERT test set, allowing the 
network to be tested. The TSU CSU ACE on the other end of the circuit 
can be looped back to test only the network. 