background image

Quick Start Guide, 612806000L1-13A, June 2006

Technical Support 1-888-4ADTRAN (1-888-423-8726)

Copyright © 2006 ADTRAN, All Rights Reserved

For more detailed documentation, visit us online at 

www.adtran.com

.

Quick Start Guide

®

TRACER 64x0 Integrated System

FRONT PANEL LEDs

With the TRACER 64x0 system powered on, the front panel LEDs provide visual 
information about the status of the system. The following table describes the LED 
operation.

For these LEDs... This color light...

Indicates that...

PWR

Green (solid)

the TRACER is connected to a power source.

Off

the TRACER is not currently powered up.

TEMP

*TRACER 64x0 high

power systems only

Green (solid)

the TRACER 64x0 high power system 
temperature is within normal range.

Red (solid)

the TRACER 64x0 high power system has an 
active temperature alarm.

FAN

*TRACER 64x0 high

power systems only

Green (solid)

the TRACER 64x0 high power system fans 
are working properly.

Red (solid)

one or more of the TRACER 64x0 high power 
system fans are not functioning.

TST

*TRACER 6420 (L1) 

only

Amber
(flashes once)

power-up self-test is in progress. If the LED 
continuously flashes or remains on (solid) 
after 10 seconds, the unit has failed self-test.

STATUS
MOD1 and MOD2

Green (solid)

the module is installed and functioning 
properly.

Red (solid)

at least one port on the installed module is 
currently in alarm.

Off

no module occupies the slot.

PLAN A

Green (solid)

the TRACER is transmitting on Frequency 
Plan A.

Off

the TRACER is not transmitting on Frequency 
Plan A.

PLAN B

Green (solid)

the TRACER is transmitting on Frequency 
Plan B.

Off

the TRACER is not transmitting on Frequency 
Plan B.

RF LO

Red (solid)

the RSSI level is below suggested minimum 
threshold (approximately 10 dBm above the 
minimum receive sensitivity).

RF DOWN

Red (solid)

there is a communication problem between 
the local and remote TRACER systems.

TRACER 64x0 MENU TREE

Frequency Plan

Site Name

System Status (0)

Rx Quality

Serial Number

9600

Rx Power

System Time

19200

off

System
Configuration (1)

Tx Power

System Date

38400

5 min

Elapsed Time

57600

10 min

Craft Port Baud

115200

15 min

Inactivity Logout

30 min

Main
Menu (M)

Password

45 min

Performance Stats Clear

60 min

Factory Default

Rx Power

RF Link
Configuration (2)

Tx Power

Band 1

RF Band Plan

Band 2

Link Encryption

Band 3

Subkey (0 - 2)

RF Link
Performance History (3)

Link Error History
Received Power History
Signal Quality History

Datapath
Provisioning (4)

Total Active Channels

IP Address

Module 1 Channels

Net Mask

Module 2 Channels

Gateway

Module 1 Menus (5)

MAC Address

Management/SNMP Port 
Configuration (0)

SNMP Mgmt

Module 2 Menus (6)

SNMP Get Community
SNMP Set Community

Management/Utilities (7)

SNMP Trap Community
SNMP Trap Hose (0 - 4)

Ping Address

Ping Utility (1)

Number of Packets
Packet Size

File Xfer Method

Timeout

TFTP Server

Ping Command

Firmware Upgrade (2)

Filename
Upgrade Destination

Delay

Command (..., Start, Abort)

Packets
(Tx, Rx, Lost)

Local Current Status
Previous Status
Remote Current Status
Previous Status
Progress

RF Link Management 
Bridge Configuration (3)

Bridge Operation
Inactivity Timeout

Link Alarm

Fan Alarms

System Alarms (8)

Local Unit

Temp Alarms

Remote Unit

Persistent Alarms Clear

Отзывы: