TRACER 4x06(L2) Frequency Conversion Document
612804106L2-18A
© 2004 ADTRAN, Inc.
3
4.
Verify the current frequency plan configuration. To verify the plan, check the connections between the
J connectors (located on the board and labeled
J1
and
J2
) and the Chan connectors (located on the
diplexer). The Chan connectors are labeled
2421
(Chan 1) and
2462
(Chan 2) for most TRACER 4106
systems and
CH1
and
CH2
for most TRACER 4206 systems. The following table outlines the
connections for Plan A and B.
Click to see a digital image of the
5.
Using the torque wrench, disconnect both cables from the Chan connectors on the diplexer. Do not
attempt to disconnect the J connectors (located on the board) as this will cause damage. Click
a digital picture of this step.
6.
Carefully flex the cables to swap the connections. Be careful with the RF cables, making sure that the
minimum bend radius of the cable is greater than 0.75"; bends and loops smaller than a quarter will
cause the RF cable to break. Use the wiring guidelines in Figure 3 and Figure 4 on page 4 for help with
wire placement.
Click
for a digital picture of this step.
Figure 3. TRACER 4106 Cable Routing Diagrams
TRACER 4x06
PLAN
CHAN 1
CHAN 2
A
J2
J1
B
J1
J2
Allowing the RF cables to sit on the processor and radio boards (green) could cause
damage to the boards; keep the RF cables off the boards while re-routing them. Click
for a digital picture of this mistake.
J2
J1
ANT
PLAN B
J1 CABLE OVER ANT CABLE
2421
2462
J2
J1
ANT
PLAN A
J2 CABLE UNDER J1 CABLE
2421
2462