61433105L1-5F

Section 61433105L1, Issue 6

1. GENERAL

This practice provides installation and maintenance
procedures for the ADTRAN Series 5 Total Reach
DDS-DP All-Rate DDS Dataport.  

Figure 1

 is an

illustration of the ADTRAN Series 5 Total Reach
DDS-DP, P/N 1433105L1.

Revision History

This document has been revised  to  incorporate the
response to the loopback pushbutton function of the
DDS-R ACE remote unit, and add reference to false
latching loopback prevention at 64 kbps.

Description

The ADTRAN Series 5 Total Reach DDS-DP  is a
functional replacement for the SLC

®

 Series 5 OCU

DP, CLEI 5SCU48, delivering data at rates up to 64
kbps using a single copper pair.  Used in combination
with the DDS-R termination unit, the Series 5

Series 5 Total Reach

®

 DDS-DP

Total Reach All-Rate DDS Dataport

Installation and Maintenance

       Section 61433105L1-5F

Issue 6, June 2002

CLEI Code: 5SC53X4F_ _

Trademarks:  Any brand names and product names included in this document are trademarks,

registered trademarks, or trade names of their respective holders.

DDS-DP can accommodate extended loop lengths,
eliminating the need for DDS repeaters.  The Series 5
DDS-DP span powers the DDS-R located at the
customer premises. The DDS-R converts the 2-wire
signal to the traditional 4-wire Alternate Mark
Inversion (AMI) signal for presentation to the
customer.

The DDS-DP occupies a single channel position in the
AT&T

®

 SLC Series 5 or Series 5 compatible channel

bank.  It provides the interface between a DS0 time
slot of the T-carrier data stream and the 2-wire
metallic loop extending to the customer premises. The
Series 5 Total Reach DDS-DP will interoperate over
the carrier system with another DDS-DP, OCU DP,
DS0 DP, 1/0 DCS, or switch and can be located in an
end office, hub office, intermediate office, or Digital
Loop Carrier (

Figure 2

).   The 2-wire loop is

connected using the odd pair Tip (pin 31) and Ring
(pin 32) on the Series 5 backplane.

NOTE

The Series 5 Total Reach DDS-DP must be used
with  an appropriate DDS-R unit.

CONTENTS

1.

GENERAL .......................................................... 1

2.

OPTIONS ........................................................... 2

3.

INSTALLATION ............................................... 3

4.

TESTING ............................................................ 4

5.

DEPLOYMENT GUIDELINES ........................ 5

6.

MAINTENANCE ............................................... 6

7.

WARRANTY AND CUSTOMER SERVICE ... 6

FIGURES

Figure 1.

Series 5 Total Reach DDS-DP ................. 1

Figure 2.

Total Reach DDS Circuit Diagram .......... 2

Figure 3.

Option Switch .......................................... 2

Figure 4.

OCU Loopback at the DDS-DP ............... 4

Figure 5.

DDS-DP Bidirectional Loopback ............ 4

Figure 6.

DDS-DP Response to DDS-R ACE
LBK Button .............................................. 5

TABLES

Table 1.

Option Settings ......................................... 2

Table 2.

Compliance Codes ................................... 3

Table 3.

LED Indication ......................................... 4

Table 4.

Cable Type and Temperature Loss
[email protected] kHz ........................................ 5

Table 5.

DDS Insertion Loss Measurements .......   5

Figure 1.  Series 5 Total Reach DDS-DP

1433105

SYNC

SX

FE

CRC

NE

DSU

QM

LBK

MAN

SW2

DDS-DP

Отзывы: