Follow these steps if you are not able to change the PC’s IP address in order to access the Web 
GUI. Change the Total Access 900 IP address to correspond with your network setup. See the 
steps below for further instruction.

Connecting to the CRAFT Port

1. Connect a VT100 terminal (or PC with VT100 emulation software) to the Total Access 900 

Series 

CRAFT

 port on the rear panel of your unit using a DB-9 (male) to DB-9 (female) 

straight-through serial cable.

2. Insert the connector of the provided power cord into the power interface on the side panel of 

the unit, and plug the cord into a standard electrical outlet.

3. Open a VT100 terminal session and configure the terminal’s COM port with the following 

parameters:

Data Rate: 9600
Data Bits: 8
Parity Bits: None
Stop Bits: 1
Flow Control: None

4. Press the 

<Enter>

 key to activate the Adtran Operating System Command Line Interface 

(AOS CLI). The AOS CLI allows you to access and control the system through a command- 
driven 

CRAFT

 connection. 

5. Enter 

enable

 at the

 >

 prompt, and enter the password when prompted. The default password 

is 

password

.   

       

Changing the Total Access 900 Series IP Address

1. Enter 

config

 

terminal

 to enter the Global Configuration mode.

2. Enter 

interface ethernet 0/1 

to access the Ethernet interface.

3. Enter 

ip address 10.10.10.1 255.255.255.0

 to assign an IP address to the Ethernet port 

using a 24-bit subnet mask. Contact your Network Administrator to obtain the IP address 
(and subnet mask) for your particular configuration.

4. Enter 

no shutdown

 to activate the interface to pass data.

5. Enter 

exit

 to exit the Ethernet interface commands and return to the Global Configuration 

mode.

Saving the Configuration

1. Enter 

exit

 to return to the Enable command security mode. 

2. At the 

#

 prompt, enter

 copy running-config startup-config

 to save the current configuration 

to memory.

3. Enter 

exit 

to close the configuration session.