The following are optional installations available for the MDU:
■
Optitap Installation
■
Fiber Splitter Installation
Opti-Tap Installation
If the MDU is equipped with an Opti-Tap Connector, refer to
and
perform the following steps:
1. Secure the Opti-Tap Connector to the housing as shown.
2. Clean each end of the fiber jumper cable using standard optical cleaning
procedures and techniques.
3. Connect one end of the fiber jumper to the green SC connector on the
bottom of the Electronics Module just to the left of the Standoff.
4. Connect the other end to the Opti-Tap Connector.
Figure 9. OptiTap Installation
Fiber Splitter Installation
If required, install the Fiber Splitter (P/N 1187734G1) by completing the
following steps:
and remove the Mounting Plungers from the Fiber
Splitter.
and position the fiber Splitter against the inside of the
MDU Housing below the Fiber Mounting bracket and secure using the
Mounting Plungers.
CAUTION
!
LASER RADIATION
Do not view directly with optical instruments.
The ONT devices used with this product contain laser emitting modules. Refer
to the ONT’s documentation and labeling for any special requirements related
to the laser module.
3. Remove dust covers from only those connectors required on the fiber
Splitter.
4. Clean each optical connection using appropriate optical cleaning
procedures and techniques.
and connect the incoming fiber to the PON port on the
Fiber Splitter. If the OptiTap is being used, connect the fiber from the
OptiTap to the PON port on the Fiber splitter.
6. Connect a fiber cable to one of the ONT ports on the Fiber Splitter and
the other to the fiber connector on the ONT.
7. Repeat steps 3, 4 and 6 for each additional ONT.
F1
DSL/POTS 25-48
F2
F3
F4
Opti-Tap Connector
and Strain Relief
(for reference only)
FiberSplitter
(for reference only)
Fiber Splitter
Mounting Bracket
Mounting Plunger
Fiber Routing
Clips
Strain Relief
(for reference only)
Fiber Routing
Tray (Included)
Strength Member
Clamp
Figure 10. Fiber Splitter Installation
8. Tie wrap all fiber cables (use the Fiber Routing Clips above the Fiber
Splitter as shown in
) and ensure all ONTs are functioning
properly before closing and securing the MDU housing door.
Provisioning Options
Refer to the appropriate
GPON OLT Installation and Maintenance Guide
to
provision the OLTs in the MDU.
M
AINTENANCE
The MDU does not require routine hardware maintenance for normal
operation. ADTRAN does not recommend that repairs be attempted in the
field. Repair services may be obtained by returning the defective unit to
ADTRAN. Refer to the warranty for further information. Field support for
software is provided through upgrade facilities.
S
PECIFICATIONS
Specifications for the MDU are as follows:
■
Electrical
♦
Maximum Input voltage: 10.5 VDC to 14 VDC
♦
Input Power: 100 watts
■
Physical
♦
Height: 20.0 inches
♦
Width: 14.0 inches
♦
Depth: 9.5 inches
♦
Weight: 25 pounds depending on number of ONT modules
■
Environmental
♦
Maximum operating temperature: –40°C to +46.1°C
♦
Maximum storage temperature: –40°C to +85°C
♦
Relative humidity: 95% non condensing
S
AFETY
AND
R
EGULATORY
C
OMPLIANCE
For Safety and Regulatory Compliance Notice information refer to the
Total
Access 480 MDU Safety and Regulatory Compliance Notice
(P/N 61287733F1-17).
ONT
Mounting Plungers
ONT
PON
C A U T I O N
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807