background image

TOTAL ACCESS 234 SHDSL NTU

P/N 1200708L1

For more detailed documentation, visit us online at  

www.adtran.com

Quick Start Guide

Quick Start Guide, 61200708L1-13B, January 2005

Technical Support 1-888-4ADTRAN or +1-256-963-8716

Copyright © 2005 ADTRAN, All Rights Reserved

C

ONNECT

 

THE

 C

ONSOLE

 I

NTERFACE

Before connecting to the Total Access 234 console interface, you will need the following items: VT100 
terminal or PC (with VT100 terminal emulation software) and a straight through serial cable with a DB-9 
(male) connector on one end and the appropriate interface for your terminal (or PC) on the other.

1. Connect the DB-9 (male) connector of your serial cable to the console port on the rear 

panel of the unit.

2. Connect the loose end of the serial cable to the VT100 terminal or PC (with terminal 

emulation software).

3. Open a VT100 terminal session to the Total Access 234 using the following settings: 

9600 baud, 8 data bits, no parity bits, and 1 stop bit. Press <Enter> to activate the 
ADTRAN Command Line Interface (CLI).

C

ONFIGURE

 G

ATEWAY

 IP A

DDRESSES

/S

UBNET

 M

ASK

Configure the Gateway IP addresses and subnet mask by following 
these steps. If you are not sure what IP address to assign, please 
contact your network administrator. 

1. Enter 

enable

 to activate the Enable command security mode. 

2. When prompted, enter the enable password (if configured).
3. Enter 

config terminal 

to activate the Global configuration mode.

4. Enter 

bre lan-gw 

10.26.12.12 

wan-gw 

100.26.12.12 mask 

255.255.255.0* 

to assign LAN and WAN Gateway IP addresses 

and subnet mask.

*Note: 

Underlined text represents example entries only. Modify 

them to match your configuration.

5. Enter 

exit

 to return to the Enable configuration mode.

6. Enter 

copy running-config startup-config

 to save the running 

configuration to the unit’s non-volatile memory (NVRAM).

NET

ETH

F

EATURES

One integrated EIA-232 configuration port (DCE)

One integrated 10/100BaseT Ethernet port

2-Wire/4-Wire SHDSL interface

WAN Protocol: ATM

Command Line Interface (CLI)

Management - EOC/CLI using Virtual Terminal 

Front panel LEDs

Wall mounting available with additional parts

S

PECIFICATIONS

DC Input Power

12 VDC nominal (8.5 VDC min, 18 VDC max); ITU-T standards: G.991.2

Diagnostics & Test

Self-diagnosis; local loopback; remote loopback

EMC Emissions

EN55022:1998 Class B; FCC Part 15 Class B

EMC Immunity, Power 
Fault, and Lightning

EN55024:1998; EN61000-3-2; EN61000-3-3; Telstra 1563; K.21 (2004) 
Enhanced

Electrical Safety

EN60950; AS/NZS 60950; UL60950 3rd ed.; 
CSA C22.2 No. 60950 3rd ed.; IEC 60950 CB Scheme

Telecom

S043.2; G.991.2

Environmental

Operating Temp: 0

o

C to 50

o

C; Storage Temp: -20

o

C to 70

o

C

*Note:

 

No stacking should be done at 50

o

C. Up to three units can be stacked at room temperature.

Humidity: 95 percent noncondensing

Dimensions

9.3 inches W x 2.1 inches H x 6.1 inches D

Connectors

SHDSL Port: RJ-45; 135 ohms; TNV-3 rated
10/100BaseT Ethernet: RJ-45 
Console Port: DB-9 female
Power Input: Kycon KPJ-3S snap & lock or equivalent

Table standoff cannot be used with this unit.

Отзывы: