background image

2

61180212L2-5A

Section 61180212L2-5, Issue 1

2. INSTALLATION

C A U T I O N 

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

Remove the Total Access 1500 Dual 4-Wire TO from
the carton and visually ensure that damage has not
occurred during shipping or handling.  If damage has
occurred, file a claim with the carrier, then contact
ADTRAN.  Refer to 

Warranty and Customer Service

section of this practice.

The Dual 4-Wire TO inserts into any Access Module
slot (1 through 24) of the Total Access 1500 chassis.

To install the Dual 4-Wire TO access module, perform
the following steps:

1. Hold the unit by the front panel while supporting

the bottom side.

2. Align the card edges to the guide grooved for the

designated slot.

3. Insert the card until the edge connector seats

firmly into the backplane.

4. Push the ejector in place to ensure the unit is fully

seated.

Compliance

Table 1

 shows the Compliance Codes for the Dual

4-Wire TO.  The Dual 4-Wire TO complies with UL
1950, third edition.  It is intended for installation in
restricted access locations only and in equipment with a
Type “B” or “E” installation code.

This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:

1. This device may not cause harmful interference.

2. This device must accept any interference received,

including interference that may cause undesired
operation.

Changes or modifications not expressly approved by
ADTRAN could void the user’s authority to operate
this equipment.

Time Slot Assignments

For time slot assignments in the Dual T1 mode and in
the Quad T1 mode, refer to 

Table 2

.

The Total Access 1500 platform can have multiple time
slots in the T1 data stream assigned to each physical
slot in the channel bank. The Total Access 1500 allows
craft selectable time slots using the electronic
provisioning interface.  The system will automatically
map DS0s in the T1 as determined by the LIU
operational configuration.  Manual mapping is available
via the LIU menu.

Connections

Four 50-pin male amphenol connectors on the rear of
the Total Access 1500 chassis provide the interconnect
wiring for each of the access module physical slots.
The Dual 4-Wire TO requires P1 (T/R) and P2 (T1/
R1) for the odd ports of each access module, while P3
(T/R) and P4 (T1/R1) for the even ports.  See

 

Table 2

for wiring interconnect details.

Code

Input

Output

Power Code (PC)

C

C

Telecommunication Code (TC)

X

Installation Code (IC)

A

Table 1.  Compliance Codes

All manuals and user guides at all-guides.com

Содержание Total Access 1500

Страница 1: ...ase of this document Future revisions to this document will be explained in this subsection GeneralDescription The Dual 4 Wire TO Access Module is intended to be deployed in the Total Access 1500 Chassis The Dual 4 Wire TO provides for two individual 4 wire analog interfaces between a VF transmission facility and the Total Access 1500 Pulse Coded Modulation PCM backplane Each TO interface provides...

Страница 2: ...evice complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received includinginterferencethatmaycauseundesired operation Changes or modifications not expressly approved by ADTRAN could void the user s authority to operate thisequipment Time Slot Assignments For time sl...

Страница 3: ...A 0 1 A 2 1 A 1 2 5 0 3 1 P 5 0 3 2 P 5 0 3 3 P 5 0 3 4 P R T 1 R 1 T R T 1 R 1 T 6 1 1 A 2 1 A 1 2 A 2 2 A 8 1 A 0 2 A 1 2 6 1 3 1 P 6 1 3 2 P 6 1 3 3 P 6 1 3 4 P R T 1 R 1 T R T 1 R 1 T 7 3 1 A 4 1 A 1 B 2 B 1 B 3 B 1 2 7 2 3 1 P 7 2 3 2 P 7 2 3 3 P 7 2 3 4 P R T 1 R 1 T R T 1 R 1 T 8 5 1 A 6 1 A 5 B 6 B 9 B 1 1 B 1 2 8 3 3 1 P 8 3 3 2 P 8 3 3 3 P 8 3 3 4 P R T 1 R 1 T R T 1 R 1 T 9 7 1 A 8 1 A ...

Страница 4: ...1 C 0 1 C 2 1 C 1 2 7 1 2 4 1 P 7 1 2 4 2 P 7 1 2 4 3 P 7 1 2 4 4 P R T 1 R 1 T R T 1 R 1 T 8 1 1 1 B 2 1 B 1 2 C 2 2 C 8 1 C 0 2 C 1 2 8 1 3 4 1 P 8 1 3 4 2 P 8 1 3 4 3 P 8 1 3 4 4 P R T 1 R 1 T R T 1 R 1 T 9 1 3 1 B 4 1 B 1 D 2 D 1 D 3 D 1 2 9 1 4 4 1 P 9 1 4 4 2 P 9 1 4 4 3 P 9 1 4 4 4 P R T 1 R 1 T R T 1 R 1 T 0 2 5 1 B 6 1 B 5 D 6 D 9 D 1 1 D 1 2 0 2 5 4 1 P 0 2 5 4 2 P 0 2 5 4 3 P 0 2 5 4 4 ...

Страница 5: ... m s n a r T P L T e v i e c e R m B d 5 8 o t 5 9 0 0 s p e t s B d 1 0 n i n o i t a u n e t t a l e n n a h c e v i e c e R t n e r r u C g n i l a e S e d o M e n o N k n i S e c r u o S n o i t a r e p o t n e r r u c g n i l a e s f o e d o m s t c e l e S Menu Navigation To traverse through the menus select the desired entry and press ENTER To work backward in the menu press the ESC escape ...

Страница 6: ...rranty and Customer Service section for further information 6 SPECIFICATIONS Specifications for the Dual 4 Wire TO are detailed in Table 5 7 WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within ten 10 years from the date of shipment if it does not meet itspublishedspecificationsorfailswhileinservice Refer to ADTRAN U S and Canada Carrier Networks Equipment Warranty Docum...

Страница 7: ... o c n E M C P µ w a l r e w o P w a r D t n e r r u C V 8 4 m u m i x a m A 0 5 0 0 l a c i s y h P s n o i s n e m i D D n i 1 0 1 x W n i 2 6 0 x H n i 5 2 1 3 t h g i e W b l 1 t n e m n o r i v n E d r a d n a t S e r u t a r e p m e T g n i t a r e p O C º 5 6 o t C º 0 4 e r u t a r e p m e T e g a r o t S C º 5 8 o t C º 0 4 y t i d i m u H e v i t a l e R g n i s n e d n o c n o n C º 0 5...

Страница 8: ...8 61180212L2 5A Section 61180212L2 5 Issue 1 All manuals and user guides at all guides com ...