Total Access 1500 Total Reach DDS-DP Installation and Maintenance Guide
8
61180105L1-5C
Provisioning and Status DS6
All
configuration
options
can
be
remotely
viewed
or
provisioned
via
DS6.
The
front
panel
remote
(
REM
)
LED
indicator
flashes
during
DS6
control
link
establishment
and
remains
ON
after
the
channel
unit
has
been
remotely
provisioned.
The
newest
provisioning
will
overwrite
any
existing
provisioning
contained
on
the
TR
DDS
‐
DP.
Time Slot Assignment
The
Total
Access
1500
platform
can
have
multiple
time
slots
in
the
T1
data
stream
assigned
to
each
physical
slot
in
the
channel
bank.
The
Total
Access
1500
allows
craft
selectable
time
slots
using
the
electronic
provisioning
interface.
AP-Switch
If
the
channel
unit
has
been
remotely
provisioned,
the
operator
can
alternate
between
remote
configuration
and
manual
switch
settings
by
pressing
the
momentary
Alternate
Provisioning
(
AP
)
switch
located
on
the
front
panel.
If
the
channel
unit
is
removed
from
the
system,
the
Total
Access
1500
bank
slot
retains
the
last
remote
provisioning
information.
A
similar
TR
DDS
‐
DP
placed
in
that
slot
will
assume
the
same
remote
provisioning.
REM Indicator
The
REM
indicator
remains
ON
when
the
channel
unit
is
operating
based
on
remote
provi
‐
sioning,
and
is
OFF
when
operating
on
manual
switches.
If
the
channel
unit
has
never
been
remotely
provisioned,
the
AP
switch
has
no
effect
and
the
REM
indicator
remains
OFF.
See
for
LED
indication.
Out-of-Band Diagnostics
In
addition
to
in
‐
band
access
to
TR
DDS
‐
DP
performance
diagnostics
and
provisioning
via
Digital
System
6,
access
is
also
available
out
‐
of
‐
band
(non
‐
intrusively)
via
the
craft
interface
located
on
the
Total
Reach
DDS
‐
R.
The
TR
DDS
‐
DP
displays
provisioning
information,
Total
Reach
system
status,
performance
monitoring
information
stored
in
15
‐
minute
and
24
‐
hour
registers
for
both
the
Total
Reach
DDS
‐
DP
and
Total
Reach
DDS
‐
R,
and
an
event
log
which
time
stamps
system
performance
anomalies
and
threshold
violations.
Physical
access
to
the
terminal
interface
on
the
Total
Reach
DDS
‐
R
is
made
by
a
serial
interface
connection
to
a
dumb
terminal
or
dumb
terminal
emulation.
Provisioning
of
the
TR
DDS
‐
DP
may
be
viewed
but
not
changed
from
the
terminal
interface
on
the
Total
Reach
DDS
‐
R.
Further
information
about
the
Total
Reach
terminal
interface
and
performance
monitoring
may
be
found
in
the
Total
Reach
OCU
‐
R
Frame
IQ
with
Craft
Interface
All
Rate
DDS
Termination
Unit
Installation
and
Maintenance
Practice
P/N
61291023L2
‐
5.