background image

Section 5, User Interface - Menu Descriptions

61179605L5-5B

5-79

4

SES 15 Minute

This option is used to enable or disable the Severely 
Errored Second setting.
SES 15 minute threshold is a count of 1-second 
intervals during which at least 50 CRC anomalies are 
declared or one or more LOSW defects are declared. 50 
CRC anomalies during a 1-second interval are 
equivalent to a 30% errored frame rate for a nominal 
frame length.
The parameters for SES are 1 to 900 seconds.

5

UAS 15 Minute

This option is used to enable or disable the Unavailable 
Second setting.
UAS 15 minute threshold is a count of 1-second 
intervals for which the SHDSL line is unavailable. The 
SHDSL line becomes unavailable at the onset of 10 
contiguous SESs. The 10 SESs are included in the 
unavailable time. Once unavailable, the SHDSL line 
becomes available at the onset of 10 contiguous seconds 
with no SESs. The 10s with no SESs are excluded from 
unavailable time.
The parameters for UAS are 1 to 900 seconds.

6

LOSWS 15 Minute

This option is used to enable or disable the Loss of 
Synchronization Word Failure setting.
LOSWS 15 minute threshold is a count of 1-second 
intervals during which one or more SHDSL LOSW 
defects are declared.
The parameters for LOSWS are 1 to 900 seconds.

7

CVC 15 Minute

This option is used to enable or disable the Code 
Violation Count setting.
CVC 15 minute threshold is a count of the SHDSL CRC 
anomalies occurring during the accumulation period.
The parameters for CVC are 1 to 65535 errors.

Table 5-56.  SHDSL Loop 1 Alarm Threshold Menu Options (Continued)

Option

Alarm Threshold

Description

Содержание Total Access 1240

Страница 1: ...Total Access 1240 Installation and Maintenance Practice Document Number 61179605L5 5B September 2005 ...

Страница 2: ... Manual The contents of this publication are current as of the date of publication ADTRAN reserves the right to change the contents without prior notice In no event will ADTRAN be liable for any special incidental or consequential damages or for commercial losses even if ADTRAN has been advised thereof as a result of issue of this publication 901 Explorer Boulevard P O Box 140000 Huntsville AL 358...

Страница 3: ...s font indicates on screen messages and prompts This font indicates text to be typed exactly as shown This font indicates silk screen labels or other system label items This font is used for strong emphasis NOTE Notes inform the user of additional but essential information or features CAUTION Cautions inform the user of potential damage malfunction or dis ruption to equipment software or environme...

Страница 4: ...product features and functions while covering applications of ADTRAN s product lines ADTRAN provides a variety of training options including customized training and courses taught at our facilities or at customer sites For inquiries concerning training contact ADTRAN Training Phone 800 615 1176 ext 7500 Training Fax 256 963 6700 Training Email training adtran com ...

Страница 5: ...ntroduction 2 1 VLAN Operation 2 3 Traffic Prioritization 2 4 System Configuration Archive 2 5 Section 3 Installation 3 1 Introduction 3 1 Shipping Contents 3 2 Required Tools 3 2 Mounting the Total Access 1240 3 3 Flush mount 3 4 Mid mount 3 5 Ground and Power Connections 3 6 Ground Connection 3 6 Power Connection 3 7 Fans Fan Filter 3 8 Ethernet Connection 3 9 Alarm Connections 3 10 SHDSL Connec...

Страница 6: ... 16 EtherType Filtering 5 17 Local Switching 5 18 Router Dest Mac Filtering Menu 5 19 Apply Provisioning to Ports Menu 5 21 Ethernet Provisioning Menu 5 23 Duplex Mode Menu 5 24 Speed Mode Menu 5 25 Current Ethernet Statistics Menu 5 26 Previous Ethernet Statistics Menu 5 28 Current Bridge Statistics Menu 5 30 Previous Bridge Statistics Menu 5 32 System Management Menu 5 34 Password Control Menu 5...

Страница 7: ...terface Mode Menu 5 73 SHDSL Loop 1 Rate Screen 5 74 SHDSL Loop 1 G 991 2 Annex Menu 5 75 SHDSL Loop 1 LineProbing Menu 5 76 SHDSL Loop 1 PMMS Margin Screen 5 77 SHDSL Loop 1 Alarm Thresholds Menu 5 78 SHDSL Loop 1 Status Menu 5 80 Alarm Status Screen 5 82 SHDSL Loop 1 Test Menu 5 83 SHDSL Loop 1 Local Loopback Menu 5 84 Local Dual Sided Loopback 5 85 Local Customer Loopback 5 85 Local Network Loo...

Страница 8: ...viii 61179605L5 5B Appendix B SCA File Format B 1 SCA Format B 1 File Format B 1 SCA File Example B 6 Appendix C Warranty C 1 Warranty and Customer Service C 1 ADTRAN Sales C 1 ADTRAN Technical Support C 1 ADTRAN Repair CAPS C 1 Repair and Return Address C 1 ...

Страница 9: ...creen 5 12 Figure 5 9 Bridge User Port Provisioning Menu 5 13 Figure 5 10 Strict Prioritization Concept Diagram 5 15 Figure 5 11 EtherType Filtering Concept Diagram 5 17 Figure 5 12 Local Switching Concept Diagram 5 18 Figure 5 13 Destination Mac Filtering Concept Diagram 5 19 Figure 5 14 Router Dest Mac Filtering Menu 5 20 Figure 5 15 Apply Provisioning to Ports Menu 5 21 Figure 5 16 Ethernet Pro...

Страница 10: ...Provisioning Menu 5 71 Figure 5 52 SHDSL Loop 1 Service State Menu 5 72 Figure 5 53 SHDSL Loop 1 Interface Mode Menu 5 73 Figure 5 54 SHDSL Loop 1 Rate Screen 5 74 Figure 5 55 SHDSL Loop 1 G 991 2 Annex Menu 5 75 Figure 5 56 SHDSL Loop 1 LineProbing Menu 5 76 Figure 5 57 SHDSL Loop 1 PMMS Margin Screen 5 77 Figure 5 58 SHDSL Loop 1 PMMS Margin Screen Worst Case Option 5 77 Figure 5 59 SHDSL Loop 1...

Страница 11: ...ions 5 24 Table 5 15 Speed Mode 100Base Menu Options 5 25 Table 5 16 Current Ethernet Statistics Menu Fields 5 26 Table 5 17 Current Ethernet Statistics Menu Hot Keys 5 27 Table 5 18 Previous Ethernet Statistics Menu Options 5 28 Table 5 19 Ethernet Statistics Previous Fields 5 29 Table 5 20 Current Ethernet Statistics Menu Hot Keys 5 29 Table 5 21 Current Bridge Statistics Menu Options 5 30 Table...

Страница 12: ...ning Menu Options 5 69 Table 5 51 SHDSL Loop 1 Provisioning Menu Options 5 71 Table 5 52 SHDSL Loop 1 Service State Options 5 72 Table 5 53 SHDSL Loop 1 Interface Mode Menu Options 5 73 Table 5 54 SHDSL Loop 1 G 991 2 Annex Menu Options 5 75 Table 5 55 SHDSL Loop 1 LineProbing Menu Options 5 76 Table 5 56 SHDSL Loop 1 Alarm Threshold Menu Options 5 78 Table 5 57 SHDSL Loop 1 Status Menu Fields 5 8...

Страница 13: ... both the SHDSL ports and the Ethernet port onto a single Printed Circuit Board PCB assembly and is powered by 48 VDC SHDSL port connections are made through a 50 pin amphenol connector Ethernet connections are made through an RJ 45 jack An alarm port and six LEDs are supported The unit is fully manageable through the craft port and an SNMP network management workstation The Total Access 1240 is r...

Страница 14: ...f 64 kbps Supports 4 wire operation supporting payload data rates of 384 2 192 kbps to 4 608 2 2 304 kbps in increments of 128 2 64 kbps System Configuration Archive SCA Supports the following operational environment NEBS GR 63 CORE ETSI EN 300 019 1 3 Class 3 1E ETSI EN 300 386 V1 3 2 2003 5 for other than telecommunications centres Class B Temperature Hardened 40 C to 70 C Security Features The ...

Страница 15: ...ce Unit is Out of Service Maintenance Failed self test No power present on unit ALARM Yellow Red Off Minor alarm is being reported from the unit Major alarm is being reported from the unit No alarms reported on unit SHDSL Green Red Off All SHDSL ports that are provisioned as In Service have completed the training sequence At least one SHDSL port that is provisioned as In Service has not completed ...

Страница 16: ...tional environment NEBS GR 63 CORE ETSI EN 300 019 1 3 Class 3 1E Storage NEBS GR 63 CORE ETSI EN 300 019 1 1 class 1 1 Earthquake NEBS GR 63 CORE zone 4 Transportation NEBS GR 63 CORE ETSI EN 300 019 1 2 class 2 3 Acoustic Noise ETS 300 753 and 2 1056 FAU 104 06 Figure 1 3 displays the compliance labels for the Total Access 1240 Figure 1 3 Total Access 1240 Compliance Labels C O N F O R M STO ANS...

Страница 17: ... thereof When operating in the 4 wire SHDSL mode if 2 wires are unavailable then the entire 4 wire circuit becomes Out of Service As shown in Figure 2 1 service providers are positioned to deploy voice data and video over the same connection triple play type services using devices such as the Total Access 1240 SHDSL DSLAM Figure 2 1 Total Access 1240 Application Voice Gateway PSTN SHDSL Modem PVCs...

Страница 18: ...eues Prioritization for the transmission of packets is performed by assigning preference to highest priority packets first and moving to lower priority packets until there is full bandwidth utilization on the subscriber ports The unit supports one to four VCs per port per RFC1483 with one VLAN per VC To utilize four VLANs the subscriber must have an RFC1483 capable modem that supports four VCs The...

Страница 19: ...t with the VC from which the packet was received The packet is discarded Condition The packet has no VLAN tag The DSLAM tags the packet with the configured VLAN ID and VLAN priority for that VC The packet is forwarded to the Network Egress point Network Side Ingress Condition The packet has a VLAN tag that matches one of the VLANs provisioned within the DSLAM The DSLAM supports up to 96 individual...

Страница 20: ...igh CBR MidH VBRrt MidL VBR Low UBR There are no rate settings for the CBR VBRrt and VBR configurations therefore these ATM COS priorities have been redefined in descending order of priority as follows 1 High 2 MidH 3 MidL 4 Low Traffic prioritization applies to the data that is forwarded to the egress of the subscriber ports Any packets that cannot be serviced due to bandwidth limitations are dis...

Страница 21: ...y of provi sioning information the SCA system can be used to clone baseline configurations to new installations so that only a few specific provisions need to be altered significantly reducing initial setup time For further information regarding SCA file format and editing the SCA file reference Appendix B SCA File Format Figure 2 3 System Configuration Archive Concept Diagram VLAN 246 File Server...

Страница 22: ...Total Access 1240 Installation and Maintenance Practice 2 6 61179605L5 5B This page is intentionally blank ...

Страница 23: ...lace them on an approved antistatic mat that is electrically grounded After unpacking the Total Access 1240 inspect it for damage If damage has occurred file a claim with the carrier then contact ADTRAN Customer Service Refer to Appendix C Warranty for further information If possible keep the original shipping container for returning the Total Access 1240 for repair or for verification of shipping...

Страница 24: ...iver Multimeter ohmmeter and voltmeter Wire strippers Side cutters Table 3 1 Total Access 1240 Shipping Contents Description Part Number Quantity Total Access 1240 1179605L5 1 Total Access 1240 Installation and Maintenance Practice 61179605L5 5 1 Cable Assembly Ground Wire 3125P037 1 Terminal Block 32024CON10 1 Mounting Bracket 19 inch 3265540 1 2 Mounting Bracket 23 inch 3265540 2 2 Screw 8 32 1 ...

Страница 25: ...umber 3265540 1 The mounting brackets used for a 23 inch rack are part number 3265540 2 The mounting brackets provide for flush or mid mounting configurations Figure 3 1 shows the Total Access 1240 mounting bracket installation options Four screws supplied with the unit are required for mounting the brackets to the system Figure 3 1 Mounting Brackets F R O N T B A C K P N 3265540 1 Mounting bracke...

Страница 26: ...use a 2 phillips head screwdriver and attach the mounting brackets to the front set of threaded screw holes with the flanges containing the slotted rack mounting holes facing the front of the Total Access 1240 Using four screws appropriate for the mounting rack and the appropriate screwdriver secure the Total Access 1240 in place on the rack Figure 3 2 Flush mount Orientation F R O N T B A C K P N...

Страница 27: ... a 2 phillips head screwdriver and attach the mounting brackets to the rear set of threaded screw holes with the flanges containing the slotted rack mounting holes facing the front of the Total Access 1240 Using four screws appropriate for the mounting rack and the appropriate screwdriver secure the Total Access 1240 in place on the rack Figure 3 3 Mid mount Orientation F R O N T B A C K Mid mount...

Страница 28: ... Ground Connection The Total Access 1240 must be grounded to a reliable grounding source To connect the ground wire perform the following steps 1 Connect the ground wire fitted with a loop terminal end to the ground lug on the front of the Total Access 1240 as shown in Figure 3 4 2 Clean the surface of the frame ground source and apply an appropriate antioxidant 3 Connect the other end of the grou...

Страница 29: ...s of both power wires NOTE ADTRAN recommends an external fuse rated between 1 5 to 2 0 amps 2 Using a small flat head screwdriver loosen the setscrews on the top of the terminal block 3 Insert the bare wire into the opening on the front of the terminal block 4 While holding the wire in place tighten the setscrew until the wire is secure 5 Repeat this procedure until all power leads are connected m...

Страница 30: ...talled If any fan fails the POWER LED turns red indicating a self test failure and a minor alarm is generates indicating the problem The fan alarm can be suppressed using the fan alarm delay for replacement or maintenance of the fan module The fans are thermostatically controlled and operate only when necessary One fan is activated first and alternates with the other fan to maintain a specified te...

Страница 31: ...works through an Ethernet port Figure 3 7 shows the location of the Ethernet port Figure 3 7 Ethernet Port The following Ethernet protocols are supported IEEE 802 3 10 100Base T IEEE 802 1Q IEEE 802 1P User Defined VLAN Priority upstream DHCP Client Mode for Management SNMP Ethernet frame sizes up to 1 522 bytes Ethernet Connection ...

Страница 32: ...aches 115 C When the units internal temperature decreases to 110 C it returns to normal operation The alarm outputs provide both normally open and normally closed pins through internal relay contacts for proper operation with a variety of alarm panels Each alarm event generates an autonomous message that is transmitted through the management VLAN channel to a monitoring device A cable with a high ...

Страница 33: ...rm the following steps 1 Connect a 25 pair female ended amphenol connector to the male ended amphenol connector labeled SHDSL 2 Tighten the screw normally provided with the amphenol connector attached to the cable on the right side of the amphenol connector 3 Use the cable tie provided placed through the tie bracket provided to secure the left side of the amphenol connector The pin assignments for...

Страница 34: ...Total Access 1240 Installation and Maintenance Practice 3 12 61179605L5 5B This page is intentionally blank ...

Страница 35: ...stem can be remotely managed through Telnet IP SNMP or Total Access EMS The Total Access 1240 default settings are shown in Table 4 1 through Table 4 5 Table 4 1 Bridge User Port Default Provisioning Options Provisioning Option Available Options Default Setting Circuit ID 29 character string VPI 0 to 4096 0 VCI 32 to 65536 35 Priority PRI High MidHigh MidH MidLow MidL Low Bridge PRI 1 High 2 MidH ...

Страница 36: ...te Table 4 3 SNMP Management Default Provisioning Options Provisioning Option Available Options Default Setting Password Control Set Login Name Not configured Access Level Read Only Technician System Administrator Not configured Control Level Read Only Read Write Not configured Allow SNMP Security Management Enabled Disabled Disabled Set Idle Logout Time 1 to 60 minutes 10 minutes IP Address Mode ...

Страница 37: ...ed SNTP Poll Interval 5 to 60 minutes in 5 minute increments 60 minutes SNTP Time Zone GMT 12 to GMT 13 GMT Baud Rate Baud Rate 9600 bps 19200 bps 38400 bps 9600 bps Table 4 4 User Port Default Provisioning Options Provisioning Option Available Options Default Setting Card Provisioning Service State In Service Out of Service Unassigned Out of Service Maintenance Out of Service Maintenance SHDSL Lo...

Страница 38: ...Threshold Disabled 1 15 minutes Disabled Loop Attenuation Alarm Threshold Disabled 1 127 dB Disabled ES 15 Minute Alarm Threshold Disabled 1 900 seconds Disabled SES 15 Minute Alarm Threshold Disabled 1 900 seconds Disabled UAS 15 Minute Alarm Threshold Disabled 1 900 seconds Disabled LOSWS 15 Minute Alarm Threshold Disabled 1 900 seconds Disabled CVC 15 Minute Alarm Threshold Disabled 1 65535 err...

Страница 39: ... string SNMP Community Names Name 52 character string Private Public Read Write IP Address 0 255 0 255 0 255 0 255 Not configured Privileges Read Read Write Read SNMP Trap Hosts Trap Port 1 to 65535 162 IP Address 0 255 0 255 0 255 0 255 Not configured Version SNMPv1 SNMPv2 SNMPv2 SNMP Traps Enabled SNMP Traps Enabled Yes No Yes External Alarms Alarm Name 25 character string Not configured Alarm S...

Страница 40: ...Total Access 1240 Installation and Maintenance Practice 4 6 61179605L5 5B This page is intentionally blank ...

Страница 41: ...ions on page 5 9 SYSTEM MANAGEMENT Total Access 1240 system management and provisioning is facilitated by a series of intuitive menus that are accessible on a computer screen The Total Access 1240 provides two methods for management access Craft Interface on page 5 1 Inband Management Interface on page 5 2 Craft Interface Connection to the Total Access 1240 system menus can be made through the DB ...

Страница 42: ...virtually all of which allow the PC or laptop to emulate a VT100 terminal Certain configuration items must be set on a PC or laptop to act as a VT100 terminal for the Total Access 1240 1 Set the parameters of the communications software to the following settings 9600 baud rate 8 data bits No parity 1 stop bit No flow control 2 Set the PC for direct connect on the appropriate communications port as...

Страница 43: ...Login prompt appears The Login screen is displayed in Figure 5 2 The Total Access 1240 system requires the login name and associated password 4 Enter the default login name ADMIN or the configured login name with System Administrator privileges and press ENTER 5 Enter the default password PASSWORD or the configured password and press ENTER Figure 5 2 Login Screen NOTE The Login name and Password f...

Страница 44: ...or can be automatically updated by the Total Access 1240 Read write Field A read write field displays information that when selected can be modified Hot Key A hot key is a key or combination of keys that are assigned to a function see Table 5 2 Hot keys are indicated by the required key s and a brief description i e N Next Port Screen A screen is a display that usually indicates the end of a menu ...

Страница 45: ... display CTRL X Control and x This keyboard command is used to force the terminal menu display to the top level ESC This keyboard command is used to return to the previous menu Spacebar This keyboard command is used to toggle the setting choices for a text field Table 5 2 Menu Specific Hot Keys Hot Key Description Ethernet Statistics C This hot key is used to clear the current Ethernet statistics ...

Страница 46: ...ioning options System Alarms A This hot key is used to acknowledge all alarms C This hot key is used to clear all alarms F This hot key is used to display the first alarm L This hot key is used to display the last alarm N This hot key is used to display the next alarm P This hot key is used to display the previous alarm R This hot key is used to reset all alarm logs T This hot key is used to displ...

Страница 47: ...o 2 Apply Provisioning 3 Exit without changes 1 Port 1 Auto Negotiate 4 SHDSL Ports 5 System Alarms 6 Contact Information 7 Logoff 1 In Service 2 Out of Service Unassigned 3 Out of Service Maintenance 1 In Service 2 Out of Service Unassigned 3 Out of Service Maintenance A B A B 1 Reset Statistics 1 Service State 2 Interface Mode 3 Rate 4 G 991 2 Annex 8 Alarm Thresholds 7 Loopback Timeout 1 Local ...

Страница 48: ... 9 Download New Code 10 Restore Factory Defaults 11 Reset System B TFTP Server TFTP Function TFTP Filename Error Status Update Progress 6 System Configuration Archive TFTP Server TFTP Function TFTP Filename Error Status Update Progress 1 Static 2 Dynamic 1 Set Passwords 2 Allow SNMP Security Management 3 Set Idle Logout Time IP Feed 2 Mode 4 Restore Default Passwords 3 Configure IP 1 Password Cont...

Страница 49: ...n on page 5 10 2 Bridge Circuit Management This option displays the Bridge Circuit Management Menu on page 5 11 3 System Management This option displays the System Management Menu on page 5 34 4 User Ports This option displays the SHDSL Ports Menu on page 5 65 5 System Alarms This option displays the System Alarm Log Screen on page 5 89 6 Contact Information This option displays the Contact Inform...

Страница 50: ...d Description Unit Name This field displays the unit name of the Total Access 1240 Part Number This field displays the part number of the Total Access 1240 Serial Number This field displays the serial number of the Total Access 1240 Production Revision This field displays the current product revision of the Total Access 1240 Software Revision This field displays the software revision of the Total ...

Страница 51: ...tion Function 1 Bridge Port Provisioning This option displays the Bridge Port Summary Screen on page 5 12 2 Ethernet Provisioning This option displays the Ethernet Provisioning Menu on page 5 23 3 Ethernet Statistics This option displays the Current Ethernet Statistics Menu on page 5 26 4 Bridge Port Statistics This option displays the Current Bridge Statistics Menu on page 5 30 Total Access 1240 ...

Страница 52: ...ield displays the current VLAN ID VPri This field displays the current VLAN priority for the port ET This field displays the Ether Type value LS This field displays the Local Switching selection Y N DMF This field displays Destination MAC Filtering status as being enabled Y or disabled N Enabled This field displays the enabled disabled status Total Access 1240 IPoE Fed Unacknowledged Alarms None B...

Страница 53: ... displays the current VLAN ID VPri This field displays the current VLAN priority for the port ET This field displays the Ether Type value LS This field displays the Local Switching selection Y N DMF This field displays Destination MAC Filtering status as being enabled Y or disabled N Enabled This field displays the enabled disabled status Total Access 1240 IPoE Fed Unacknowledged Alarms None Bridg...

Страница 54: ...ation to each circuit See Strict Prioritization on page 5 15 7 Select Destination Mac Filters This option displays the Router Dest Mac Filtering Menu on page 5 19 8 VLAN ID This option is used to assign a VLAN ID The VLAN ID is used to uniquely identify a particular VLAN per IEEE 802 1 Q The parameter for a VLAN ID is a number between 1 and 4094 9 VLAN Priority This option displays the VLAN Priori...

Страница 55: ... of the subscriber SHDSL ports As described above Four VCs can be configured on each SHDSL port There are four priority settings High CBR MidH VBRrt MidL VBR and Low UBR There are no rate settings for the cbr vbrrt and vbr configurations therefore these ATM Class of Service COS prior ities have been redefined as High MidH MidL and Low priorities Figure 5 10 Strict Prioritization Concept Diagram To...

Страница 56: ... as the lowest and 7 as the highest priority Table 5 9 lists an example of how traffic types might be organized in a network implementation NOTE Actual settings depend on the traffic types used in a particular network Table 5 9 Traffic Type Examples VLAN Priority Traffic Type 0 Best effort 1 Background 2 Best effort 3 Excellent effort 4 Controlled load 5 Video 6 Voice ...

Страница 57: ...s IP PPPoE Any Packets that do not meet the provisioned EtherType are discarded Figure 5 11 EtherType Filtering Concept Diagram Total Access 1240 Ethernet Vlan 101 EthFilt PPPoE Vlan 112 EthFilt Any Vlan 124 EthFilt IP Either packet type is forwarded If the packet s EtherType is PPPoE it is forwarded if not it is discarded This applies in both directions If the packet s EtherType is IP it is forwa...

Страница 58: ...s enabled and both subscribers are on the same VLAN The data is forwarded to the correct port as determined by the MAC Learning Table This option is applied on a per VC basis Figure 5 12 Local Switching Concept Diagram Total Access 1240 Ethernet Vlan 101 LS off Ingress Egress Ingress Egress SHDSL ports 1 24 Port 1 Port 2 Port 23 Port 24 Vlan 101 LS off Vlan 124 LS on Vlan 124 LS on ...

Страница 59: ...es is discarded and traffic with the configured Mac addresses is forwarded Broadcast traffic is forwarded in either case Selecting Disabled allows the filtering to be turned off even if the Mac addresses are configured Figure 5 13 Destination Mac Filtering Concept Diagram Total Access 1240 Ethernet Vlan 101 DMF enabled Ingress Egress Ingress Egress SHDSL ports 1 24 Port 1 Port 2 Port 23 Port 24 Vl...

Страница 60: ...er This option is used to either enable or disable Mac filtering 4 Save Changes This option is used to save configuration changes made within this menu This option must be used to implement any provisioning adjustments 5 9 Router MAC Addr These options are used to enter non Multicast MAC Addresses in Hex format in the following format XX XX XX XX XX XX Total Access 1240 IPoE Fed Unacknowledged Ala...

Страница 61: ...orts to copy to This option is used to select the specific destination port numbers that provisioning is to be copied 2 Apply Provisioning This option is used to apply provisioning to the ports selected from option 1 3 Exit without changes This option is used to exits the menu without changes Total Access 1240 IPoE Fed Unacknowledged Alarms None Apply Provisioning to Ports Warning This is service ...

Страница 62: ...e VPI assigned to port VCI This field displays the VCI assigned to port PRI This field displays the traffic priority setting VLAN This field displays the VLAN assigned to port VPri This field displays the Virtual Path setting ET This field displays the EtherType filtering assigned to this VC LS This field indicates if Local Switching is enabled or disabled DMF This field indicates if Destination M...

Страница 63: ...rovisioning Menu The Ethernet Provisioning menu options are shown in Table 5 13 Table 5 13 Ethernet Provisioning Menu Options Option Description Function 1 Duplex Mode This option displays the Duplex Mode Menu on page 5 24 2 Speed This option displays the Speed Mode Menu on page 5 25 Total Access 1240 IPoE Fed 09 01 05 03 44 Unacknowledged Alarms None Ethernet Provisioning 1 Duplex Mode Full Duple...

Страница 64: ...n in Table 5 14 Table 5 14 Duplex Mode Menu Options Option Description Function 1 Auto Negotiate This option sets the system to automatically detect the duplex mode of the attached device 2 Full Duplex This option sets the Ethernet interface to transmit and receive simultaneously 3 Half Duplex This option sets the Ethernet interface to transmit or receive at a given time but not simultaneously Tot...

Страница 65: ... are shown in Table 5 15 Table 5 15 Speed Mode 100Base Menu Options Option Description Function 1 Auto Negotiate This option sets the system to automatically detect the speed of the attached device 2 100Base This option sets the Ethernet interface to transmit and receive at 100 mb s 3 10Base This option sets the Ethernet interface to transmit and receive at 10 mb s Total Access 1240 IPoE Fed 09 01...

Страница 66: ...ts successfully received to the unit Errored Received Packets This field displays the number of packets received with errors to the unit Broadcast Received Packets This field displays the number of packets received by the layer addressed as broadcast Multicast Received Packets This field displays the number of packets received by the layer addressed as multicast Received CRC Errors This field disp...

Страница 67: ...nt Ethernet Statistics menu hot keys are shown in Table 5 17 Table 5 17 Current Ethernet Statistics Menu Hot Keys Hot Key Description C This hot key is used to clear the current Ethernet statistics J This hot key displays the Previous Ethernet Statistics Menu on page 5 28 ...

Страница 68: ...riod of Ethernet statistics 4 3 4 This option is used to display the fourth 15 minute period of Ethernet statistics 5 Newest This option is used to display the newest 15 minute period of Ethernet statistics 6 Prev This option is used to display Ethernet statistics for the previous port 7 Next This option is used to display Ethernet statistics for the next port Total Access 1240 IPoE Fed 09 01 05 0...

Страница 69: ...his field displays the number of packets successfully received to the unit Errored Rx Packets This field displays the number of packets received with errors to the unit Broadcast Rx Packets This field displays the number of packets received by the layer addressed as broadcast Multicast Rx Packets This field displays the number of packets received by the layer addressed as multicast Rx CRC Errors T...

Страница 70: ... Table 5 21 The Current Bridge Statistics menu fields are shown in Table 5 22 Table 5 21 Current Bridge Statistics Menu Options Option Description Function 1 Port This option is used to select a port 2 Bridge This option is used to select a bridge Total Access 1240 IPoE Fed Unacknowledged Alarms INFO Circuit ID No Circuit ID Current Bridge Statistics VC Enabled Modem Not Trained 1 Port 1 Interface...

Страница 71: ... good packets successfully received by the Total Access 1240 Bad Packets This field displays the number of bad packets received by the Total Access 1240 Good Bytes This field displays the number of good bytes successfully transmitted to the Total Access 1240 Bad Bytes This field displays the number of bad bytes transmitted to the Total Access 1240 ATM Statistics Tx Cells This field displays the nu...

Страница 72: ...play the fourth 15 minute period of bridge statistics 5 Newest This option is used to display the newest 15 minute period of bridge statistics 6 Prev This option is used to display bridge statistics for the previous port 7 Next This option is used to display bridge statistics for the next port Total Access 1240 IPoE Fed 09 01 05 02 32 Unacknowledged Alarms INFO Previous Bridge Statistics 15 Minute...

Страница 73: ...kets This option displays the number of packets successfully received to the unit Errored Rx Packets This option displays the number of packets received with errors to the unit Successful Rx Bytes This option displays the number of bytes successfully received from the unit Errored Rx Bytes This option displays the number of bytes received with errors from the unit ATM Tx Cells This option displays...

Страница 74: ...urrent IP Settings Menu on page 5 39 3 Test IP Address This option displays the Test IP Address Menu on page 5 45 4 Time Date This option displays the Time Date Adjust Menu on page 5 46 5 Baud Rate This option displays the Current Baud Rate Menu on page 5 48 6 System Configuration Archive This option displays the System Configuration Archive Screen on page 5 49 7 SNMP This option displays the SNMP...

Страница 75: ...5 57 9 Download New Code This option displays the Code Download Method Menu on page 5 59 10 Restore Factory Defaults This option displays the Restore Factory Defaults Menu on page 5 63 11 Reset System This option displays the Reset System Menu on page 5 64 Table 5 27 System Management Menu Options Continued Option Description Function ...

Страница 76: ...tions Option Description Function 1 Set Passwords This option displays the Password Control Levels Screen on page 5 37 2 Allow SNMP security management This option is used to enable or disable SNMP security management 3 Set Idle Logout Time This option is used to set the time allowed before an automatic logout is performed This option must be set between 1 and 60 minutes 4 Restore Default Password...

Страница 77: ...s for a default usernames are shown in Table 5 29 Table 5 29 Password Control Levels for Default Usernames Username Access Level Control Level ADMIN System Administrator Read write and password control READWRITE Technician Read write READONLY Read only Read only Total Access 1240 IPoE Fed Unacknowledged Alarms None Password Control Levels User Status Login Read Only Not Configured Technician Confi...

Страница 78: ... the TAB key to navigate to the Password field The Password field displays in reverse video 4 Press the spacebar to open the field type a password and press ENTER 5 Enter the password again when prompted to verify and press ENTER 6 Press the TAB key to navigate to the Access Level field The Access Level field displays in reverse video 7 Press the spacebar to change the access level and press ENTER...

Страница 79: ...ic or Dynamic In Static Mode the IP address Subnet mask and Default Gateway are set for inband management of the Total Access 1240 In Dynamic Mode the Total Access 1240 acts as a Dynamic Host Configuration Protocol DHCP client and a DHCP server is required upstream from the Total Access 1240 When a DHCP server is properly configured the Total Access 1240 system obtains the IP address Subnet mask a...

Страница 80: ... 3 Configure IP Depending on the setting of the Mode option the Configure IP option displays one of the following menus Static IP Settings for IP over Ethernet Menu on page 5 40 Dynamic IP Settings for IP over Ethernet Menu on page 5 43 Table 5 30 Mode Selection and Current IP Settings Menu Options Continued Option Description Function Total Access 1240 IPoE Fed Unacknowledged Alarms None Static I...

Страница 81: ...o forward traffic to a destination outside of the subnet of the Total Access 1240 The Default Gateway is configured in decimal dot format 4 TFTP IP address This option is used to configure the TFTP IP address The TFTP IP address must be configured to use TFTP for software upgrade The TFTP address is configured in decimal dot format 5 Reset IP Factory Defaults This option displays the Restore IP Fa...

Страница 82: ...ure 5 28 is used to reset all of the IP factory defaults CAUTION This is service affecting If IP factory defaults are enabled remotely IP connectivity is lost Figure 5 28 Restore IP Factory Defaults Menu Total Access 1240 IPoE Fed 09 01 05 03 52 Unacknowledged Alarms None Restore IP Factory Defaults 1 Yes Service Affecting Selection System Help Screen ...

Страница 83: ...iption Function 1 TFTP IP address This option is used to configure the TFTP IP address The TFTP IP address must be configured to use TFTP for software upgrade The TFTP address is configured in decimal dot format 2 Renew DHCP Lease This option is used to manually renew information from the DHCP server 3 Reset IP Factory Defaults This option displays the Restore IP Factory Defaults Menu on page 5 44...

Страница 84: ...ure 5 30 is used to reset all of the IP factory defaults CAUTION This is service affecting If IP factory defaults are enabled remotely IP connectivity is lost Figure 5 30 Restore IP Factory Defaults Menu Total Access 1240 IPoE Fed 04 01 05 08 09 Unacknowledged Alarms None Restore IP Factory Defaults 1 Yes Service Affecting Selection System Help Screen ...

Страница 85: ... address that is to be tested 2 Ping Timeout This option is used to set the number of seconds that should pass between pings 3 Number of Pings This option is used to set the number of pings that are to be sent during testing of the IP address 4 Start Ping This option is used to initiate the ping test 5 Start Traceroute This option is used to display the route taken to reach the IP address that is ...

Страница 86: ...Y format 3 SNTP Status This option is used to enable or disable the SNTP capabilities Simple Network Time Protocol SNTP is a connection less User Datagram Protocol UDP used to synchronize the time with a high accuracy network time server 4 SNTP Server Addr This option is used to set the SNTP server address The SNTP server address must be entered in decimal form in the box provided separated by per...

Страница 87: ... is based from the GMT and a valid input can be offset from 12 to 13 hours from GMT Once the IP address of the SNTP server and the desired poll interval is configured the Total Access 1240 polls the specified server IP address from the time of day updates at the specified poll interval Table 5 34 Time Date Adjust Menu Options Continued Option Description Function ...

Страница 88: ...he rate changes immediately and the terminal emulation software must be updated to reflect the change Table 5 35 Current Baud Rate Menu Options Option Description Function 1 9600 This option configures the baud rate to 9600 bps 2 19200 This option configures the baud rate to 19200 bps 3 38400 This option configures the baud rate to 38400 bps Total Access 1240 IPoE Fed 09 01 05 03 54 Unacknowledged...

Страница 89: ...P Server The TFTP address is entered in decimal dot format i e TFTP Function This field is used to enter the function to perform via TFTP Available functions are Store file to Server Retrieve file from Server TFTP Filename This field is used to enter the filename to be stored to or retrieved from the server via TFTP The filename must end with a cfg extension Total Access 1240 IPoE Fed Unacknowledg...

Страница 90: ...update filename and path Verify appropriate permissions are selected for the specified path Update Progress This field displays the progress of the TFTP transfer Progress messages are as follows Contacting Server This message indicates that an attempt to establish communication with the TFTP network server specified by the server address in the TFTP Server IP Address field is in progress Beginning...

Страница 91: ...37 Table 5 37 SNMP Configuration Menu Options Option Description Function 1 Contact Information This option displays the SNMP Contact Information Menu on page 5 52 2 Community Names This option displays the SNMP Community Names Menu on page 5 53 3 Trap Hosts This option displays the SNMP Trap Hosts Menu on page 5 55 4 Traps Enabled This option toggles between Yes and No to enable or disable the tr...

Страница 92: ... field including spaces and special characters such as an underscore 2 Name This option is used to enter a user specified text string for the name of the Total Access 1240 This name helps distinguish the Total Access 1240 between different installations Up to 45 alphanumeric characters can be entered in this field including spaces and special characters such as an underscore 3 Location This option...

Страница 93: ...figure the first SNMP community Settings include Private and Public 2 IP Address This option is used to configure the first SNMP community IP address in decimal dot format i e 3 Privileges This option is used to configure the first SNMP community privilege level Options include Read Write and Read 4 Name This option is used to configure the second SNMP community Settings include Private and Public...

Страница 94: ...This option is used to configure the third SNMP community Settings include Private and Public 8 IP Address This option is used to configure the third SNMP community IP address in decimal dot format i e 9 Privileges This option is used to configure the third SNMP community privilege level Options include Read Write and Read Table 5 39 SNMP Community Names Menu Options Continued Option Description F...

Страница 95: ...s Menu Options Option Description Function 1 IP Address This option is used to configure the first SNMP trap host IP address in decimal dot format i e 2 Version This option is used to configure the SNMP version for the first SNMP trap host Options include the following SNMPv1 SNMPv2 3 IP Address This option is used to configure the second SNMP trap host IP address in decimal dot format i e Total A...

Страница 96: ...v1 SNMPv2 5 IP Address This option is used to configure the third SNMP trap host IP address in decimal dot format i e 6 Version This option is used to configure the SNMP version for the third SNMP trap host Options include the following SNMPv1 SNMPv2 7 Trap Port This option is used to configure the SNMP trap port The trap port is defaulted to port 162 and is provisionable for cases in which port 1...

Страница 97: ... used to enter a 25 character text string for Alarm 2 3 Alarm 3 Text This option is used to enter a 25 character text string for Alarm 3 4 6 Severity Options 4 to 6 are used to assign severity levels to each of the three external alarms For more information refer to External Alarm Severity Menu on page 5 58 7 Fan Alarm Delay This option is used to set the delay for amount of time it takes for an a...

Страница 98: ...evels are user defined based on the impact to customer service Table 5 42 External Alarm Severity Menu Options Option Description Function 1 Critical This option is used to designate a critical alarm 2 Major This option is used to designate a major alarm 3 Minor This option is used to designate a minor alarm 4 Load Shedding This option is used to designate an alarm that shuts down SHDSL services T...

Страница 99: ...st be configured to use TFTP Figure 5 41 Code Download Method Menu The Code Download Method menu options are shown in Table 5 43 Table 5 43 Code Download Method Menu Options Option Description Function 1 Y Modem This option displays the Y Modem Download Menu on page 5 60 2 TFTP This option displays the TFTP Firmware Download Screen on page 5 61 Total Access 1240 IPoE Fed 09 01 05 03 55 Unacknowled...

Страница 100: ...al select Transfer from the menu and select Send 4 Navigate to the appropriate location and choose the file that contains the code to be downloaded CAUTION The code begins transmitting from the terminal emulation package When the download is complete the unit restarts automatically NOTE If downloading both Flash A and Flash B code repeat steps 3 through 4 choosing the code not previously downloade...

Страница 101: ...TFTP Server This field displays the IP address of the TFTP server The TFTP IP address must be configured prior to attempting a TFTP download Get Code For This field displays the module that will be upgraded TFTP Filename This field displays the TFTP filename that will be used to upgrade the module shown in the Get Code For field The TFTP filename must be known and must match the part number Total ...

Страница 102: ... the TFTP network server has been established and the update file is being transferred between TFTP network server and the Total Access 1240 Completed This message indicates that the Total Access 1240 successfully received the update file Error Status This field displays the status of the TFTP download The Error Status messages are as follows File Not Found This status indicates that the TFTP netw...

Страница 103: ...shown in Table 5 45 Table 5 45 Restore Factory Defaults Menu Options Option Description Function 1 Restore This option is used to restore all SNMP settings to the factory default settings 2 Exit This option is used to return to the System Management Menu on page 5 34 The factory defaults are not restored Total Access 1240 IPoE Fed 09 01 05 01 25 Unacknowledged Alarms None Restore Factory Defaults ...

Страница 104: ... 45 Reset System Menu The Reset System menu options are shown in Table 5 46 Table 5 46 Reset System Menu Options Option Description Function 1 Reset This option is used to reboot the Total Access 1240 All system options are retained 2 Exit This option is used to return to the display to the System Management Menu on page 5 34 The system does not reboot Total Access 1240 IPoE Fed 09 01 05 03 56 Una...

Страница 105: ...ning Menu on page 5 68 3 Status This option displays the SHDSL Loop 1 Status Menu on page 5 80 4 Alarms This option displays the Alarm Status Screen on page 5 82 5 Test This option displays the SHDSL Loop 1 Test Menu on page 5 83 6 Performance This option displays the SHDSL Loop 1 Performance Screen on page 5 88 7 Remote Terminal This option is used to set a remote terminal SHDSL provides an overh...

Страница 106: ... Loop number displayed indicates the current loop number being viewed or provisioned There are two descriptors for each SHDSL field LTU Line Terminating Unit NTU Network Terminating Unit The SHDLSL Loop 1 Configuration fields are shown in Table 5 48 09 01 05 03 57 Total Access 1240 SHDSL Loop 1 Configuration LTU NTU Vendor ID ADTN N A Part Number 1179605L5 N A Serial Number E49A1314 N A Product Re...

Страница 107: ...e Equipment Identifier CLEI of the unit This field displays the Common Language Equipment Identifier CLEI of the modem SHDSL Version This field displays the unit SHDSL Version This field displays the modem SHDSL Version Vendor List Number This field displays the unit Vendor List Number This field displays the modem Vendor List Number Vendor Issue Number This field displays the unit Vendor Issue Nu...

Страница 108: ... the SHDSL Circuit IDs Figure 5 48 Provisioning Menu The Provisioning menu options are shown in Table 5 49 Table 5 49 Provisioning Menu Options Option Description Function 1 Card This option displays the Card Provisioning Menu on page 5 69 2 SHDSL This option displays the SHDSL Loop 1 Provisioning Menu on page 5 71 09 01 05 03 57 Total Access 1240 Provisioning 1 Card 2 SHDSL Selection System Help ...

Страница 109: ...scription Function 1 Service State This option is used to select the card service state The available service states are as follows In Service The SHDSL services are available if installed and Link Down and Threshold alarms are reported Out of Service Unassigned No SHDSL services are available No Link Down and Threshold alarms are reported Out of Service Maintenance SHDSL services are available No...

Страница 110: ...he main circuit board card CAUTION This action is service affecting If the system is accessed remotely through a static IP address the system resets and access is lost Figure 5 50 Restore factory Defaults Screen 09 01 05 01 34 Total Access 1240 Restore Factory Defaults WARNING This may cause service to be interrupted This defaults only the SHDSL Ports Provisions Do you wish to continue Y N System ...

Страница 111: ...Mode Menu on page 5 73 3 Rate This option displays the SHDSL Loop 1 Rate Screen on page 5 74 4 G 991 2 Annex This option displays the SHDSL Loop 1 G 991 2 Annex Menu on page 5 75 5 Lineprobing PMMS This option displays the SHDSL Loop 1 LineProbing Menu on page 5 76 6 PMMS Margin This option displays the SHDSL Loop 1 PMMS Margin Screen on page 5 77 7 Loopback Timeout This option is used to enable o...

Страница 112: ...L Loop 1 Service State Options Option Description Function 1 In Service This option makes SHDSL services available if installed and Link Down and Threshold alarms are reported 2 Out of Service Unassigned This option makes SHDSL services unavailable and no Link Down and Threshold alarms are reported 3 Out of Service Maintenance This option makes SHDSL services available and no Link Down and Thresho...

Страница 113: ...ons Figure 5 53 SHDSL Loop 1 Interface Mode Menu The SHDSL Loop 1 Interface Mode menu options are shown in Table 5 53 NOTE The line rate on both pairs must be the same Table 5 53 SHDSL Loop 1 Interface Mode Menu Options Option Description Function 1 2 wire This option sets the interface mode to single pair operation SHDSL offers rates from 192 kbps to 2 3 Mbps in increments of 64 kbps 2 4 wire Thi...

Страница 114: ...een see Figure 5 54 is used to set the rate for the Circuit ID Figure 5 54 SHDSL Loop 1 Rate Screen The rates defined in SHDSL standard G 991 2 are N 64 kbits s where N 3 192 kb s to 36 2304 kb s 09 01 05 03 09 Total Access 1240 SHDSL Loop 1 Rate Enter a value for N from 3 to 36 where the payload rate N x 64 Kbps System Help ...

Страница 115: ...shown in Table 5 54 Table 5 54 SHDSL Loop 1 G 991 2 Annex Menu Options Option Description Function 1 A This option is used to specify Annex A Annex A is used for North American applications 2 B This option is used to specify Annex B Annex B is used for European applications 3 A B This option is used to specify that the Total Access 1240 is to auto detect the setting of the attached device 09 01 05...

Страница 116: ...ed the units will immediately attempt to train Figure 5 56 SHDSL Loop 1 LineProbing Menu The SHDSL Loop 1 LineProbing menu options are shown in Table 5 55 SHDSL Loop 1 LineProbing Menu Options Option Description Function 1 Disabled Line probing is disabled 2 Enabled Current Condition Current Condition specifies that the line probing sequence should determine the maximum rate it can run given the c...

Страница 117: ...e line probe algorithm to maximize the rate against the specified margin Figure 5 57 SHDSL Loop 1 PMMS Margin Screen Figure 5 58 SHDSL Loop 1 PMMS Margin Screen Worst Case Option 09 01 05 03 07 Total Access 1240 SHDSL Loop 1 PMMS Margin Enter a Current Condition Margin value for N from 0 to 20 in dB System Help 09 01 05 03 14 Total Access 1240 SHDSL Loop 1 PMMS Margin Enter a Worst Case Condition ...

Страница 118: ...o determine alarm status The parameters for SNR Margin are 1 to 15 dB 2 Loop Attenuation This option is used to enable or disable the Loop Attenuation setting Loop Attenuation is used to set a loop loss value from 1 to 27 dB which determines alarm status The parameters for Loop Attenuation are 1 to 127 dB 3 ES 15 Minute This option is used to enable or disable the Errored Second setting ES is a co...

Страница 119: ...the onset of 10 contiguous SESs The 10 SESs are included in the unavailable time Once unavailable the SHDSL line becomes available at the onset of 10 contiguous seconds with no SESs The 10s with no SESs are excluded from unavailable time The parameters for UAS are 1 to 900 seconds 6 LOSWS 15 Minute This option is used to enable or disable the Loss of Synchronization Word Failure setting LOSWS 15 m...

Страница 120: ...ndshaking Trained Payload Rate This field displays the speed of the data over the SHDSL circuit which does not include SHDSL framing overhead This field displays the speed of the data over the SHDSL circuit which does not include SHDSL framing overhead Interface Mode This field displays the interface mode Values include the following 2 wire 4 wire This field displays the interface mode Values incl...

Страница 121: ...errors from the SHDSL modem SES This field displays the running count of seconds with 832 or more CRC errors from the unit This field displays the running count of seconds with 832 or more CRC errors from the SHDSL modem UAS This field displays the running count of seconds where link access is not available from the unit This field displays the running count of seconds where link access is not ava...

Страница 122: ...e date the alarm occurred 09 01 05 03 11 Total Access 1240 Page 1 of 1 Alarm Status Total Alarms 6 Date Time Level Port Description Status 04 01 05 02 29 59 Major EQPT Rear Fan Failure Cleared 04 01 05 02 29 54 Major EQPT Front Fan Failure Cleared 04 01 05 02 29 50 Major EQPT Fan Module Removed Cleared 04 01 05 02 29 10 Major EQPT Rear Fan Failure Active 04 01 05 02 29 10 Major EQPT Front Fan Fail...

Страница 123: ...st menu options are shown in Table 5 58 Table 5 58 SHDSL Loop 1 Test Menu Options Option Description Function 1 Local Loopback This option displays the SHDSL Loop 1 Local Loopback Menu on page 5 84 2 Remote Loopback This option displays the SHDSL Loop 1 Remote Loopback Menu on page 5 86 09 01 05 03 14 Total Access 1240 SHDSL Loop 1 Test 1 Local Loopback Inactive 2 Remote Loopback N A Selection N N...

Страница 124: ...e 5 59 Table 5 59 SHDSL Loop 1 Loopback Menu Options Option Description Function 1 Dual Sided This option is used to initiate a dual sided loopback For more information refer to Local Dual Sided Loopback on page 5 85 2 Customer This option is used to initiate a customer side loopback For more information refer to Local Customer Loopback on page 5 85 3 Network This option is used to initiate a netw...

Страница 125: ...pback The local customer loopback provides a loopback at the LTU in the customer direction as shown in Figure 5 65 An Alarm Indication Signal AIS is injected into the network side Figure 5 65 Local Customer Loopback Local Network Loopback The local network loopback provides a loopback at the LTU in the network direction as shown in Figure 5 66 An AIS signal is injected into the customer side Figur...

Страница 126: ...able 5 60 SHDSL Loop 1 Remote Loopback Menu Options Option Description Function 1 Dual Sided This option is used to initiate a remote dual sided loopback For more information refer to Remote Dual Sided Loopback on page 5 87 2 Customer This option is used to initiate a remote customer loopback For more information refer to Remote Customer Loopback on page 5 87 3 Network This option is used to initi...

Страница 127: ...dication Signal AIS is injected into the network side Figure 5 69 Remote Customer Loopback Remote Network Loopback The remote network loopback is initiated at the NTU in the network direction as shown in Figure 5 70 AIS signal is injected into the customer side Figure 5 70 Remote Network Loopback The initiation or removal of any loopback test does not interfere with any interface not being tested ...

Страница 128: ...L modem SES This field displays the number of SES errors from the unit This field displays the number of SES errors from the SHDSL modem UAS This field displays the number of UAS errors from the unit This field displays the number of UAS errors from the SHDSL modem LOSWS This field displays the number of LOSWS errors from the unit This field displays the number of LOSWS errors from the SHDSL modem...

Страница 129: ...d Alarms None System Alarm Log Alarms 1 to 10 of 10 Page 1 of 1 Date Time Level Description Status 04 01 05 2 01 41 Info 1 Active 04 01 05 3 01 34 Info 1 Active 04 01 05 2 54 11 Info 1 Active 04 01 05 2 38 40 Info 1 Active 04 01 05 2 38 34 Info 0 Active 04 01 05 2 38 30 Info 0 Active 04 01 05 2 38 14 Info 0 Active 04 01 05 2 36 00 Info Network Feed is IPoE Active 04 01 05 2 35 47 Info Alarm Log Re...

Страница 130: ...Figure 5 73 displays ADTRAN technical support repair and online support contact information Figure 5 73 Contact Information Screen Total Access 1240 IPoE Fed 09 01 05 03 16 Unacknowledged Alarms None Contact Information Adtran Technical Support 800 726 8663 Adtran Repair CAPS 256 963 8722 Online Support www adtran com System Help Screen ...

Страница 131: ...ss 1240 does not require routine maintenance for normal operation ADTRAN does not recommend that repairs be attempted in the field Repair services can be obtained by returning the defective unit to ADTRAN Refer to the Appendix C Warranty section for further information ...

Страница 132: ...Total Access 1240 Installation and Maintenance Practice 6 2 61179605L5 5B This page is intentionally blank ...

Страница 133: ...ting Temperature Storage Temperature Relative Humidity Maximum Current Draw Maximum Heat Dissipation 40 C to 70 C 40 C to 85 C 95 percent maximum at 50 C non condensing 0 625 amps maximum at 48 VDC 30 watts Physical Dimensions Weight Height 44 45 millimeters 1 75 inches 1 mounting unit Width 438 15 millimeters 17 25 inches Depth 282 575 millimeters 11 125 inches 7 5 pounds Part Number Total Access...

Страница 134: ...Total Access 1240 Installation and Maintenance Practice 7 2 61179605L5 5B This page is intentionally blank ...

Страница 135: ...ille Alabama USA Declares that the product TA1240 24 Port 2W 4W SHDSL DSLAM 1179605L5 is in conformity with the following directives and standards Electromagnetic Compatibility Directive 89 336 EEC as amended by 92 31 EEC 93 68 EEC EN 300 386 V 1 3 2 2003 05 Low Voltage Directive 73 23 EEC and 93 68 EEC EN60950 2000 Authorized Signatory Jeffrey W Whitmire Manager Regulatory Compliance Date March 2...

Страница 136: ...Total Access 1240 Installation and Maintenance Practice A 2 61179605L5 5B This page is intentionally blank ...

Страница 137: ...E 06 14 05 BEGIN isfs BRIDGEPORTSSETTINGS Internal Filename Do not Change 05 10 05 Date Code Do not Change user1b1 Port Identifier Do not Change No Circuit ID Circuit ID Text String 0 35 1 1 0 0 0 1 See Table B 1 for fields a b c d e f g and h No MAC Address MAC Address 1 to filter on xx xx xx xx xx xx No MAC Address MAC Address 2 to filter on xx xx xx xx xx xx No MAC Address MAC Address 3 to filt...

Страница 138: ... c d and e END isfs VLANPORTSETTINGS Internal Filename Do not Change Table B 1 Bridge User Ports Field Option Values a VPI INT 0 4096 b VCI INT 32 65535 c Priority INT 0 Low 3 MidL 2 MidH 1 High d Reserved Do not Change e Ethertype Filtering INT 0 ANY 1 IP 2 PPOE f Local Switching 0 Disabled 1 Enabled g Destination MAC Filtering 0 Disabled 1 Enabled h Port 0 Disabled 1 Enabled Table B 2 VLANPORTSE...

Страница 139: ...ariable Name Do not Change C 1 2 3 4 5 6 7 8 Column Header Do not Change Column Separator Do not Change 7 0 0 0 0 0 0 a4 See Table B 4 below by column number Table B 3 SNTPCSETTINGS Field Option Values a SNTP Server IP address Decimal format XXX XXX XXX XXX b Polling Interval 0 Disabled 1 to 30 in minutes c Offset from GMT 12 IDLW 11 NT 10 HST 9 AKST 8 YDT 7 PDT 6 MDT 5 CDT 4 EDT 3 BRA 2 AT 1 WAT ...

Страница 140: ...Values 1 Number of Options Do not change 2 Card Service State 0 SERVICE_STATE_IN_SERVICE 1 SERVICE_STATE_OOS_UNASSIGNED 2 SERVICE_STATE 3 Powerdown Timeout 0 Disabled 1 to 999 timeout in minutes 4 Fan Alarm Delay 0 Disabled 1 to 15 delay in minutes 5 8 RESERVED for Future Use Table B 5 LocSTULineProvisioning Column Option Values 1 Number of options Do not change 2 Line Service State 0 SERVICE _STA...

Страница 141: ...here rate N 64k 8k E Max Line Rate N 3 to 36 where rate N 64k 8k F Current Line Rate N 3 to 36 where rate N 64k 8k 10 Min Sub Rate N 0 to 7 where rate Line Rate N 8k 11 Max Sub Rate N 0 to 7 where rate Line Rate N 8k 12 PMMS Margin CC 10dB to 20dB 13 PMMS Margin WC 10dB to 20dB 14 Clock Mode 0 Plesio 1 Plesio w Reference 2 Sync 3 Sync Hybrid 15 Framing Mode 0 Frame Plesio 1 Frame Sync 2 Frame Tran...

Страница 142: ...sabled 1 to 900 threshold in seconds 19 SHDSL SES 15 Minute Alarm Threshold 0 Disabled 1 to 900 threshold in seconds 1A SHDSL UAS 15 Minute Alarm Threshold 0 Disabled 1 to 900 threshold in seconds 1B SHDSL CVC 15 Minute Alarm Threshold 0 Disabled 1 to 65535 threshold in seconds 1C SHDSL LOSWS 15 Minute Alarm Threshold 0 Disabled 1 to 900 threshold in seconds 1D Line Rate Control 0 STU C 1 STU R 1E...

Страница 143: ... e 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 26 2 0 0 0 0 1 0 0 0 2 0 20 20 20 0 0 0 0 2 1 e 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 26 2 0 0 0 0 1 0 0 0 2 0 20 20 20 0 0 0 0 2 1 e 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 26 2 0 0 0 0 1 0 0 0 2 0 20 20 20 0 0 0 0 2 1 e 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 26 2 0 0 0 0 1 0 0 0 2 0 20 20 20 0 0 0 0 2 1 e 12 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 26 2 0 0 0 0 1 0 0 0 2 0 20 20...

Страница 144: ...Total Access 1240 Installation and Maintenance Practice B 8 61179605L5 5B This page is intentionally blank ...

Страница 145: ...es support Customer and Product Service CAPS requests or further information ADTRAN Sales Pricing Availability 800 827 0807 ADTRAN Technical Support Pre Sales Applications Post Sales Technical Assistance 800 726 8663 Standard hours Monday Friday 7 a m 7 p m CST Emergency hours 7 days week 24 hours day ADTRAN Repair CAPS Return for Repair Upgrade 256 963 8722 Repair and Return Address Contact CAPS ...

Страница 146: ...Carrier Networks Division 901 Explorer Blvd Huntsville AL 35806 ...

Отзывы: