background image

2

Section 61244065L1-5, Issue 1

61244.065L1-5A

5.

TEST SETUPS

When using the TAC to test pairs, consideration must be given
to the configuration setup for the type of test being performed
to ensure a valid test. Available access is detailed in Table A.

To loopthru the CO pairs to the field pairs, put SW1 in the
LOOPTHRU position as indicated on the card (see Figure 3).
This bridges the circuit pairs.

For test access using the TAC, insert the TAC into the repeater
housing. For the single slot housing, the print on the TAC
should face away from the pole or wall. For the four-slot
housing, the print on the TAC should face the label of the
position you are testing.

Testing the CO Pairs
To loopback the circuit, put SW1 in the LOOPBACK position
as indicated on the card (see Figure 2). This loops the circuit
back to the CO and to the field.

Table A. Available Access

Label

P7

P13

P5

P15

P41

P47

P55

P49

P17

P1

P11

P35

Description

LOOP1 Transmit towards NET

LOOP1 Receive towards CUST

LOOP1 Transmit towards CUST

LOOP1 Receive towards CUST

LOOP2 Transmit towards NET

LOOP2 Receive towards NET

LOOP2 Transmit towards CUST

LOOP2 Receive towards CUST

-48 RET

Frame Ground

Frame Ground

-48 volts

Figure 2. SW1 Loopback Configuration

To short the CO pairs, put SW1 in the SHORT position as
indicated on the card (see Figure 4). This connects transmit to
receive on each loop.

Figure 3. SW1 Loopthru Configuration

To open the circuit, put SW1 in the OPEN position as indicated
on the card (see Figure 5). This allows for a voltage measurement
across pairs.

Figure 4. SW1 Short Configuration

6.

MAINTENANCE

The ADTRAN T400 TAC requires no routine maintenance.
ADTRAN does not recommend that repairs be performed in
the field. Repair services may be obtained by returning the
defective unit to ADTRAN.

7.

WARRANTY AND CUSTOMER SERVICE

ADTRAN will replace or repair this product within five years
from the date of shipment if it does not meet its published
specifications or fails while in service (see ADTRAN Equipment
Warranty, Repair, and Return Policy and Procedure).

Return Material Authorization (RMA) is required prior to returning
equipment to ADTRAN.

For service, RMA requests, or further information, contact one
of the following numbers:

ADTRAN Technical Support ............. (800) 726-8663
Standard support hours, Monday-Friday, 7am-7pm CST
Emergency Support: 7 days/week, 24 hours/day

ADTRAN Sales ................................... (800) 827-0807

ADTRAN Repair/RMA ........................ (800) 963-8722

Repair and Return Address

ADTRAN, Inc.
Customer Service Department
901 Explorer Boulevard
Huntsville, Alabama 35806-2807

Figure 5. SW1 Open Configuration

LOOP BACK

LOOP 1

LOOP 2

P7

T

P13 R

P41 T
P47 R

T

P5

R P15

T

P55

R P49

CUST

NET

LOOP THRU

LOOP 1

LOOP 2

P7

T

P13 R

P41 T
P47 R

T

P5

R P15

T

P55

R P49                

CUST

NET

SHORT

LOOP 1

LOOP 2

P7

T

P13 R

P41 T
P47 R

T

P5

R P15

T

P55

R P49

CUST

NET

OPEN

LOOP 1

LOOP 2

P7

T

P13 R

P41 T
P47 R

T

P5

R P15

T

P55

R P49

CUST

NET

Отзывы: