background image

  1

Section 61244065L1-5, Issue 1

61244.065L1-5A

T400 TAC

TEST ACCESS CARD

INSTALLATION/MAINTENANCE

PRACTICES

Section 61244065L1-5

Issue 1, March 1997

CLEI #NCTEAAA _ _ _

1.

GENERAL

Revision History
Revisions to this practice will be summarized in this paragraph.

This practice is an installation and maintenance guide for the
ADTRAN T400 Test Access Card (TAC). Figure 1 is an
illustration of the card.

Features
The ADTRAN T400 TAC is a test card for installing and
troubleshooting circuits that have T400 mechanics. The TAC
accesses the four pairs that connect of the card-edge socket
for metallic and functional testing of the pairs. T400 TAC
features include:

• Plugs into ADTRAN T400 housings 1150087L1 and

1150043L1 and L2

• Provides complete testing of wire pairs

• Easy-access of pairs

The four position switch on the card provide a means for the
following:

• Looping back the co-pairs and field pairs

• Bridging across pairs

• Shorting loop 1 and loop 2

• Opening loop 1 and loop 2

Figure 1.  ADTRAN T400 TAC

2.

INSTALLATION

After unpacking the unit, immediately inspect it for possible
shipping damage.  If damage is discovered, file a claim
immediately with the carrier, then contact ADTRAN Customer
Service.

3.

APPLICATIONS

The ADTRAN TAC enables the Telco craft personnel to test
the wire pairs from the repeater location. Testing of the circuit
is accomplished by removing the repeater, inserting the TAC,
and then selecting the appropriate switch setting; i.e.,
LOOPBACK, LOOPTHRU, SHORT, or OPEN.

4.

FUNCTIONAL DESCRIPTION

The ADTRAN TAC may be used in the single T400 housing,
part number 1150087L1, or the four-slot T400 housing, part
number 1150043L1 or L2. The eight connectors, labelled
LOOP1, T, R (CO), T, R (FIELD), provide direct access to the
wire pair.

LOOP1 and LOOP2 access points labelled T and R (CO)
connect to the wire pairs toward the central office and access
points labelled T and R (FIELD) connect to the wire pairs
toward the customer (FIELD).

The switch labeled SW1 selects the four functions illustrated in
Figure 1 for the four states of LOOPBACK, LOOPTHRU,
SHORT, and OPEN.

Trademarks:

Any brand names and product names included in this document are trademarks, registered
trademarks, or trade names of their respective holders.

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

LOOP BACK

LOOP THRU

SHORT

OPEN

LOOP 1

LOOP 2

P7

T

P13 R

P41 T
P47 R

T

P5

R P15

T

P55

R P49

CUST

NET

LOOP 1

LOOP 2

P7

T

P13 R

P41 T
P47 R

T

P5

R P15

T

P55

R P49                

CUST

NET

LOOP 1

LOOP 2

P7

T

P13 R

P41 T
P47 R

T

P5

R P15

T

P55

R P49

CUST

NET

LOOP 1

LOOP 2

P7

P5

T

NET

CUST

P13

P15

R

T

R

LOOP
BACK
LOOP
THRU

SHORT

OPEN

SW1

P41

P55

T

NET

CUST

P47

P49

R

T

R

P17

P1/P11

FRM
GND

-48
RET

P35

-48V

1996

5244.065-1D

c

LOOP 1

LOOP 2

P7

T

P13 R

P41 T
P47 R

T

P5

R P15

T

P55

R P49

CUST

NET

CONTENTS

1. GENERAL ...................................................................... 1
2. INSTALLATION ............................................................... 1
3. APPLICATIONS ............................................................... 1
4. FUNCTIONAL DESCRIPTION .......................................... 1
5. TEST SETUPS ................................................................ 2
6. MAINTENANCE ............................................................... 2
7. WARRANTY AND CUSTOMER SERVICE 
........................ 2

FIGURES

Figure 1.  ADTRAN T400 TAC ................................................ 1
Figure 2.  SW1 Loopback Configuration ................................... 2
Figure 3.  SW1 Loopthru Configuration .................................... 2
Figure 4.  SW1 Short Configuration .......................................... 2
Figure 5.  SW1 Open Configuration 
......................................... 2

TABLES

Table A.  Available Access ...................................................... 2

Отзывы: