Chapter 2. Installation and Operation
32
T3SU 300 User Manual
61202217L1-1B
•
Rubber feet for stand-alone use
Customer Provides
The customer provides an interface cable for each port used. Each
cable should be either HSSI, V.35, or an 8-pin modular cable,
depending on the interface type.
POWER UP
The AC version of the T3SU 300 is provided with a captive eight-
foot power cord, terminated by a three-prong plug which connects
to a grounded 115 VAC power receptacle.
A three-position terminal block which accommodates
12 to 26 AWG wire is located on the rear panel of the T3SU 300 DC
version. The positive (+) and negative (-) terminals connect to a
24 to 48 VDC, 0.4A power source. Figure 2-1 on page 33 provides
an illustration of the terminal block power connector, along with
definitions for the three connector symbols.
The ADTRAN T3SU 300 MIB is available in the support section of
the ADTRAN web page at www.adtran.com.
Power to the AC version of the T3SU 300 must be provided from a
grounded 115 VAC, 60 Hz receptacle.
The chassis should be connected to an earth ground.
Содержание T3SU 300
Страница 20: ...20 T3SU 300 User Manual 61202217L1 1B ...
Страница 24: ...24 T3SU 300 User Manual 61202217L1 1B ...
Страница 30: ...Chapter 1 Introduction 30 T3SU 300 User Manual 61202217L1 1B ...
Страница 42: ...Chapter 2 Installation and Operation 42 T3SU 300 User Manual 61202217L1 1B ...
Страница 78: ...Chapter 4 Status 78 T3SU 300 User Manual 61202217L1 1B ...
Страница 92: ...Chapter 5 Statistics 92 T3SU 300 User Manual 61202217L1 1B ...
Страница 126: ...Appendix C Acronyms Abbreviations 126 T3SU 300 User Manual 61202217L1 1B ...
Страница 138: ...Appendix D Glossary 138 T3SU 300 User Manual 61202217L1 1B ...