background image

T200 SHDSL SINGLE PORT NTU

JOB

A

ID

61225135L1-22A

0206

TX

RX

G.

7

0

3

V.

2

4

1225135L1

LOC

L
B
K

REM

G.703

SHDSL

PWR

SHDSL

NTU

BERT

ALM

LBK

T200 SHDSL

SINGLE PORT

NTU 

LED INDICATORS

PWR

Off

No power

Green

Adequate power

SHDSL

Green

SHDSL Loop is trained 

Yellow

SHDSL Loop is trained with marginal signal quality (SNR
margin)

Red

SHDSL Loop is not trained

G.703

Off

G.703 port not configured, or in alarm condition

Green

G.703 port configured and no alarms

ALM

Off

No alarm condition detected

Yellow

Remote alarm condition detected

Red

Alarm condition detected locally

LBK

Off

Module is not in loopback

Green

Local loopback is active

BERT

Off

Module is not in BERT

Green

BERT running with no errors

Blinking Yellow

Module is running a BERT with bit errors

Red

BERT running with no pattern sync

LOOPBACK PUSHBUTTONS

LOC – Initiates a customer transparent loopback at the NTU

REM – Initiates a network transparent loopback at the LTU

BANTAM JACKS

TX 

– G.703 signal received from the customer

RX

– G.703 signal transmitted to the customer

POWERING

The LTU provides -113 VDC of span power over the SHDSL loop to the NTU, or the
NTU can be locally powered with a -48 VDC supply.

PROVISIONING

Used to access performance monitoring data, perform loopbacks and provision units
via VT100 emulation software such as Hyper Terminal – Private Edition and
ProComm Plus.  When using a PC with terminal software, be sure to disable any
power saving programs.  Provision terminal port as follows:

Data Rate

– 1.2 to 19.2 kbps

Asynchronous Data Format

– eight data bits, no parity (none), one stop bit

There are two types of terminal emulation modes, Manual and Real Time.  Use 
“CTRL-T” to toggle between the two modes.

Manual Emulation Mode

Press the space bar 3 times to manually update the screen. Print screen and log file
commands are available in this mode.

Real-Time Emulation Mode

The default mode. Print screen and log file commands are not available in this mode.
Cursor placement and screen highlighting are enabled.

Refer to the menu tree on the reverse side to navigate the SHDSL NTU menu options.

DEFAULT PROVISIONING OPTIONS

Provisioning Option

Default Value

Unit  Options

Local Management 

Enabled

SHDSL Options

Aggregate Rate

N/A

SNR Margin Alarm Threshold (dB)

Disabled

Loop Attenuation Alarm Threshold (dB)

Disabled

Line Probing

Disabled

G.703 Options

ISDN-PRA V3

Disabled

G.704 CRC-4 Multiframing

Disabled

G.704 Idle Pattern

FFh

Network Spare Bits Insertion

Disabled

Network Spare Bits Pattern

N/A

Customer Spare Bits Insertion

Disabled

Customer Spare Bits Pattern

N/A

Customer RAI Generation

Disabled

Customer E-bit Generation

N/A

Test Options

SHDSL Remote Loopback

Disabled

SHDSL BERT

Normal

G.703 Local Loopback

Enabled

COMPLIANCE

This product is intended for installation in restricted access locations only and in
equipment with a type “B” or “E” enclosure.

WARRANTY 

Warranty for Carrier Networks products manufactured by ADTRAN and supplied under
Buyer’s order for international use is five (5) years.  For a complete copy of ADTRAN’s

International Equipment Warranty,

part number 60000003#I-3: (877) 457-5007, 

faxback Document 583.

■  

For a complete Installation and Maintenance Practice: (877) 457-5007,  faxback Document 768.  Please have your fax number ready.  

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

Code

Input Output

Power Code (PC)

F

C

Telecommunication Code (TC) –

X

Installation Code (IC)

A

#61225135L1-22A#