10
61222026L1-5, Issue 1
61222026L1-5A
The Performance History Screens, illustrated in
Figure 11, Figure 12
, and
Figure 13
display the
historical HDSL2 and T1 performance data in several
different registers. At each 15-minute interval, the
performance information is transferred to the
15-minute performance data register. This unit stores
performance data in 15-minute increments for the last
24-hour period. Additionally, some units store up to
48 hours worth of 60-minute interval data.
CIRCUIT ID: 01/01/00 00:06:47
Press ESC to return to previous menu
Menu 15 Minute H2TUC DSX-1 Performance Data
1. Definitions ES-P SES-P UAS-P SAS-P ES-PFE CV-P
2. Reset Data 000 000 000 000 000 00000
3. 15 Min Data 00:00 000 000 000 000 000 00000
4. 60 Min Data 23:45 000 000 000 000 000 00000
5. 24 Hr Data 23:30 000 000 000 000 000 00000
6. Line Data 23:15 000 000 000 000 000 00000
7. Path Data 23:00 000 000 000 000 000 00000
8. H2TUC DSX-1 22:45 000 000 000 000 000 00000
9. H2TUC LOOP 22:30 000 000 000 000 000 00000
10. H2TUR LOOP 22:15 --- --- --- --- --- -----
11. H2TUR DS1 22:00 --- --- --- --- --- -----
21:45 --- --- --- --- --- -----
21:30 --- --- --- --- --- -----
21:15 --- --- --- --- --- -----
Selection:
Figure 11. 15-Minute Performance History Path Data Screen
At each 24-hour interval, the performance data is
transferred into the 24-hour performance data
registers. This unit stores up to 31 days of 24-hour
interval data.
The user is prompted to select a module and interface
to view the corresponding performance data. Line (L)
and Path (P) related data can be viewed.
_ _ _ _ _ _
--8-->| | | |---->
| C |<-9--10->| R |
<-----|_ _ _| |_ _ _|<-11-