NetVanta Dual T1/FT1 Network Interface Module (NIM)
P/N 1200872L1
For more detailed documentation, visit us online at
www.adtran.com
.
Quick Start Guide
®
Quick Start Guide, 61200872L1-13F, November 2006
Copyright © 2006 ADTRAN, All Rights Reserved
S
PECIFICATIONS
Operating
Modes
Frame Relay, Multilink Frame Relay,
PPP, Multilink PPP, HDLC
T1/FT1
Interfaces
Supported Standards: AT&T TR 62411, AT&T TR 54016,
Bellcore TR 194, ANSI T1.403
Line Rate: 1.544 Mbps ±75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples of 64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build-Out: 0, -7.5, -15, -22.5 dB (long),
0 to 655 ft (short)
Connector: RJ-48C
DS0 Assignment: Programmable
Clock Source
Network, internal, through
Diagnostics
Test pattern Generation and Detection: QRSS, 511,
2
15
- 1, 2
20
- 1, all ones, all zeros
Network loopbacks (local and remote); responds to both
inband and FDL loop codes
Alarm generation and detection
Network and user sets of performance data (15 minutes
and 24 hours)
Compliance
FCC Part 15 Class A, EN 55022 Class A
ACTA/FCC Part 68, IC CS-03
UL/CUL 60950
Physical
Dimensions: 2.75-inch W x 4.25-inch D
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
NetVanta modules should be installed only in
NetVanta Series products.
WAN T1/1
DBU
WAN T1/2
I
NSTALLATION
I
NSTRUCTIONS
1.
Remove power from the unit.
2.
Slide the option module into the option slot until the module is firmly
seated against the chassis.
3.
Secure the pins at both edges of the module.
4.
Connect the cables to the associated device(s).
5.
Complete the installation of the base unit.
6.
Restore power to the unit.
For NetVanta modules with outside plant
connections, ensure that all cables are removed
from the module before installing or removing it
from the NetVanta chassis.
WAN T1/1
AND
T1/2 N
ETWORK
(RJ-48C) C
ONNECTION
P
INOUTS
Pin
Name
Description
1
R1
Receive data from the network - Ring 1
2
T1
Receive data from the network - Tip 1
3
—
Unused
4
R
Transmit data toward the network - Ring
5
T
Transmit data toward the network - Tip
6-8
—
Unused
An optional Dial Backup Interface Module (DIM) is
required for dial backup applications.
For a description of the DBU pinouts, refer to the Quick
Start Guide included with your DIM shipment.
Important:
For additional details on product features,
specifications, installation, and safety, refer to the
appropriate Hardware Installation Guide on the
ADTRAN OS System Documentation
CD shipped with
the base unit and available online at www.adtran.com.