Technical S1-256-963-8716

64200868L1-42A

4

Creating the E1 Interface TDM Group

The following steps demonstrate configuring an E1 network interface with timeslots 1-
15 for data.

1. At the 

(config-e1 1/1)#

 prompt, enter 

framing crc4 

.

2. Enter 

sa4tx-bit 0 

.

3. Enter 

tdm-group 1 timeslots 1-15 speed 64

  to create a TDM group for timeslots 1-

15 (the data timeslots) on the E1 network connection (e1 1/1).

4. Enter 

no shutdown

 to activate the interface.

5. Enter 

interface e1 1/2

 to activate the interface configuration mode for the G.703 

network interface.

6. Enter 

no shutdown

 to activate the interface.

7. Enter 

exit

 to return to the global configuration mode.

The NetVanta automatically maps timeslots 1-31 from the network connection of the E1/FE1 
+ G.703 NIM to the G.703 port. Creating a TDM group removes the specified timeslots from 
the G.703 map. All remaining timeslots not included in the TDM group will be passed from 
the network port (e1 1/1) to the G.703 port (e1 1/2).

Voice circuits require timeslot 16 for signaling.  If voice is required on the e1 1/2 G.703 port, 
the largest data map which can be configured is timeslots 1-15 (leaving 17-31 for voice) or 
17-31 (leaving 1-15 for voice).

Timeslot 0 is for synchronization, alarm transport, and international carrier use. It is not 
accessible for use for voice or data.

Skip to step 7 for PPP configuration.

Содержание NetVanta Series

Страница 1: ...gram Branch Office Corporate HQ NetVanta LAN IP 10 10 10 1 24 WAN IP 192 168 72 2 30 eth 0 1 LAN IP 10 10 20 7 24 PWR STAT TD VPN RD TD RD TD RD WAN LAN PWR STAT TD VPN RD TD RD NetVanta 3200 WAN LAN...

Страница 2: ...Console Session 1 Connect a VT100 terminal or PC with VT100 emulation software to the NetVanta CONSOLE port using a DB 9 male to DB 9 female straight through serial cable 2 Configure the COM port with...

Страница 3: ...interface to pass data 4 Enter exit to exit the Ethernet interface commands and return to the global configuration mode The NetVanta Network Interface Modules NIMs use a slot port notation for interfa...

Страница 4: ...tivate the interface 7 Enter exit to return to the global configuration mode The NetVanta automatically maps timeslots 1 31 from the network connection of the E1 FE1 G 703 NIM to the G 703 port Creati...

Страница 5: ...now display config fr 1 16 2 Enter frame relay interface dlci 16 to assign DLCI 16 to this PVC 3 Enter ip address 192 168 72 1 255 255 255 252 to assign an IP address of 192 168 72 1 for this PVC usin...

Страница 6: ...1 Static Route to the Far Side Internet Access at Local Site 1 Set up the static route ip route 10 10 10 0 255 255 255 0 ppp 1 or frame relay 1 16 2 Set up the default route ip route 0 0 0 0 0 0 0 0 1...

Страница 7: ...ons are activated See the following step Step 11 for information on password configuration 11 Setting the Enable Security Mode Password 1 Verify that the prompt of your unit displays config 2 Enter en...

Отзывы: