NetVanta ADSL Network Interface Module (ADSL Over POTS)
P/N 1200869L1
For more detailed documentation, visit us online at
www.adtran.com
.
Quick Start Guide
®
Quick Start Guide, 61200869L1-13D, November 2005
Technical Support 1-888-4ADTRAN (1-888-423-8726)
Copyright © 2005 ADTRAN, All Rights Reserved
WAN-ADSL
DBU
I
NSTALLATION
I
NSTRUCTIONS
1.
Remove power from the base unit.
2.
Slide the option module into the option slot until the module is firmly
seated against the chassis.
3.
Secure the pins at both edges of the module.
4.
Connect the cables to the associated device(s).
5.
Complete installation of the base unit.
6.
Restore power to the base unit.
NetVanta modules should be installed only in
NetVanta Series products.
WAN-ADSL (RJ-11C) P
INOUTS
Pin
Name
Description
1, 2
—
Unused
3
R
Network - Ring
4
T
Network - Tip
5, 6
—
Unused
An optional Dial Backup Interface Module (DIM) is
required for dial backup applications.
For a description of the DBU pinouts, refer to the
Quick Start Guide included with your DIM
shipment.
Important:
For additional details on product
features, specifications, installation, and safety, refer
to the appropriate Hardware Installation Guide on
the
ADTRAN OS System Documentation
CD
shipped with the base unit and available online at
www.adtran.com.
S
PECIFICATIONS
ADSL Interface
ADSL over POTS, Annex A
Supported Standards:
ITU-T G.992.1 Annex A (G.dmt)
ITU-T G.992.2 Annex A (G.lite)
ITU-T G.992.3 Annex A ADSL2 (G.dmt.bis)
ITU-T G.992.5 Annex A ADSL2+
ITU-T G.992.3 Annex L READSL2
ANSI T1.413 Issue 2
Connector: RJ-11C (6-pin jack, inner pair)
Dying Gasp (NetVanta 3200 only)
ATM
Multiple Protocol over AAL5 (RFC2684)
PPP over ATM (RFC2364)
PPP over Ethernet (RFC2516)
ATM Forum UNI 3.1/4.0 PVC
ATM Class of Service (UBR)
ATM F5 OAM
Up to 16 Virtual Circuits
Compliance
FCC Part 15 Class A, EN 55022 Class A, EN 55024,
EN 61000-3-2, EN 61000-3-3
ACTA/FCC Part 68, IC CS-03, AS/ACIF S043,
AS/ACIF S002
EN 60950, IEC 60950, UL/CUL 60950, AS/NZS 60950
Physical
Dimensions: 2.75-inch W x 4.25-inch D
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing