ADTRAN NetVanta 1561i-04 Скачать руководство пользователя страница 3

617111561F1-13A

3

3. Ensure that the switch is level and attached securely to the DIN rail as shown in 

Figure 4

.

Figure 4. Switch Securely Attached to DIN Rail

Wall Mounting the NetVanta 1561i-04 Switch

Follow these instructions to mount the NetVanta 1561i-04 switch to a wall using the enclosed wall mounting kit: 

1. Attach the wall-mounting brackets to the rear panel of the switch chassis and drive the provided screws into the metal screw receptacles on the back of the 

switch as shown in 

Figure 5

. Tighten the screws with a Phillips-head screwdriver to secure the brackets to the switch.

Figure 5. Attach Wall-mount Brackets to Switch

2. Using the mounting bracket as a template, mark the location on the wall to insert user-provided screw anchors. Screw anchors should be rated to support a 

minimum of 2.2 pounds (1 kg) for the intended wall mount surface. Wall mount bracket dimensions are shown in 

Figure 6

.

Figure 6. Wall Mount Bracket Dimensions

3. Follow the manufacturer’s instructions to install the user-provided screw anchors. Install the screw anchors in the wall at the marks made in Step 2. Correctly 

installed screw anchors should have the edge of the anchor lip protrude approximately 1/16-inch (1.6mm) from the wall.

4. Mount the switch on the wall by inserting user-provided 1/4-inch (5.4mm to 6.8mm) diameter screws through the recessed holes in the mounting bracket and 

driving them into the user-provided screw anchors.

5. Ensure that the switch is attached securely to the wall.

Содержание NetVanta 1561i-04

Страница 1: ...h on page 8 Product Specifications on page 8 Figure 1 NetVanta 1561i 04 Front Panel Layout WARNING f Read all warning cautions notes and installation instructions before installing or servicing this e...

Страница 2: ...stomer Support For more information refer to the product warranty available online at https adtran wp_support_warranty Mounting the NetVanta 1561i 04 Switch on a DIN Rail Follow these instructions to...

Страница 3: ...g the mounting bracket as a template mark the location on the wall to insert user provided screw anchors Screw anchors should be rated to support a minimum of 2 2 pounds 1 kg for the intended wall mou...

Страница 4: ...I DO Relay Wires to the Switch The NetVanta 1561i 04 switch provides digital input and digital output signals using relay wires connected to the provided terminal block To install the DI DO terminal b...

Страница 5: ...external device if one is connected The default state of the DO relay can be configured via software to be either opened or closed and when a user configured event is triggered the DO relay connectio...

Страница 6: ...us of the PC is OK 5 Run your web browser on the PC enter either the DHCP assigned or factory default IP address to access the switch s web interface If your PC is configured correctly you will see th...

Страница 7: ...e is not receiving power from Power1 On The device is powered ON correctly P2 Green Off The device is not receiving power from Power2 On The device is powered ON correctly LED Color State Description...

Страница 8: ...iguration 2 to 7 seconds Blinking Green All LED lights are OFF Restore to Factory Default 7 to 12 seconds Blinking Green All LED lights stay ON LED Behavior Possible Cause Basic Troubleshooting Steps...

Страница 9: ...ed by ADTRAN could void the user s authority to operate this equipment This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Ru...

Отзывы: