2. Slide the keyed insets on the bottom of the unit’s chassis securely onto the screws.

Figure 7. Attaching the Switch to the Wall

Supplying Power to the Switch

To connect the AC power cord to the switch, complete the following steps.

1. Connect the AC power cord to the AC power receptacle on the rear panel of the switch. 
2. Connect the other end of the AC power cord to a properly grounded AC power outlet. The AC branch circuit socket-outlet must be installed near the 

equipment and must be easily accessible.

3. Confirm that the power is connected properly. The 

SYSTEM

 LED should be 

ON

 (see 

“SYSTEM Status LED”

).

Figure 8. Connecting the AC Power Cord

CAUTION!

f

The NetVanta 1560-08 must be mounted in the face-down orientation when wall mounted.

NOTE

g

The installation of this product must comply with the national, state and local electrical code requirements, as applicable. The AC branch circuit 

overcurrent protection must be a fuse or circuit breaker rated 125 VAC, 20 Amps maximum or 250 VAC, 16 Amps maximum. A readily accessible 

disconnect device that is suitably approved and rated must be incorporated in the field wiring.

CAUTION!

f

It is recommended that an external AC Surge Protection Device be installed at the AC input connection to the local AC-Powered product. The Surge 

Protection device should provide L-N, L-G, and N-G protection. It is also recommended that the device contains a visual 'GOOD' indicator.

WARNING!

f

This equipment incorporates double pole/neutral fusing. If the neutral fuse opens and the line fuse does not open, voltage could still be present in the 

unit.

Содержание NetVanta 1560-08

Страница 1: ...n instructions before installing or servicing this equipment NetVanta 1560 08 SYSTEM CONSOLE USB RESET 1 2 3 4 5 6 7 8 9 10 9 10 RESET Button Port Status LEDs SYS LED CONSOLE Port 10 100 1000 RJ 45 Po...

Страница 2: ...he chassis in the stationary equipment rack Allow 1 inch of clearance between units NOTE g Refer to the national state and local electrical codes for the requirements for power grounding wiring and in...

Страница 3: ...ach the four adhesive rubber feet to the bottom of the switch Figure 5 Attaching the Rubber Feet Mounting the Switch on a Wall To mount the switch on a wall complete the following steps 1 Using the mo...

Страница 4: ...be mounted in the face down orientation when wall mounted NOTE g The installation of this product must comply with the national state and local electrical code requirements as applicable The AC branc...

Страница 5: ...h is connected to a DHCP server skip to Step 3 2 Reconfigure the PC s IP address and subnet mask as below so that it can communicate with the switch For example the method to change the PC s IP addres...

Страница 6: ...e needed PC with VT100 terminal emulation software Micro USB to USB cable or a DB 9 to RJ45 Serial Cable the cables are provided along with the unit To initially configure the switch using the CLI com...

Страница 7: ...ving packets and the connection speed is 1 Gbps Amber On The port is enabled has established a link to connected device and the connection speed is 100 Mbps Flashing The port is transmitting receiving...

Страница 8: ...quipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CAN ICES 003 A NMB 003 A CAUTION f This pr...

Отзывы: