ADTRAN NetVanta 1560-08-150W Скачать руководство пользователя страница 4

4

617108108PF2-13D

Connect AC Power

To connect the AC power cord to the switch, complete the following steps.

1. Connect the AC power cord to the AC power receptacle on the rear panel of the switch. 
2. Connect the other end of the AC power cord to a properly grounded AC power outlet. 
3. Confirm that the power is connected properly. The 

SYSTEM

 LED should be ON (see 

“SYSTEM Status LED”

).

Figure 8. Connecting the AC Power Cord

Install SFP Modules

You can install or remove a mini-GBIC SFP module from a SFP port without having to power off the switch. To install an SFP module, complete the 

following steps.

1. Insert the module into the appropriate SFP port. 
2. Press firmly to ensure that the module seats properly into the connector.

Figure 9. Installing an SFP Module into an SFP Port

g

     NOTE

This product is intended for use with a Class 1 Laser module that complies with FDA 21 CFR 1040.10, 1040.11 and IEC 60825-1. For continued 

compliance with the above standards, only approved Class 1 Laser modules from an ADTRAN approved vendor list (located online at 

www.adtran.com

should be installed in this product. ADTRAN cannot certify system integrity with other laser modules.

Initially Configuring the Switch

The Switch can be configured by two methods:

Web based Graphical User Interface (GUI)

Command Line Interface (CLI)

Initial Switch Configuration Using a Web Browser

After powering up the switch for the first time, you can perform the initial switch configuration using a web browser. 
To begin with the initial configuration stage, you need to reconfigure your PC’s IP address and subnet mask to make sure the PC can communicate with 

the switch. After changing PC’s IP address (for example, 10.10.10.250), then you can access the web interface of the switch using the switch’s default IP 

address as shown below.

Содержание NetVanta 1560-08-150W

Страница 1: ...ur adhesive rubber feet Quick Start f WARNING The NetVanta 1560 08 150W is intended for indoor use only Ethernet PoE cables and attached equipment are intended for use within the same building with eq...

Страница 2: ...the switch into a 19 inch rack complete the following steps 1 Attach the mounting brackets to both sides of the chassis Insert the screws and tighten them with a screwdriver to secure the brackets Fi...

Страница 3: ...r sufficient air flow Mounting on a Wall To mount the switch on a wall complete the following steps 1 Using the mounting holes on the bottom of the unit as a template install the user supplied screws...

Страница 4: ...intended for use with a Class 1 Laser module that complies with FDA 21 CFR 1040 10 1040 11 and IEC 60825 1 For continued compliance with the above standards only approved Class 1 Laser modules from an...

Страница 5: ...ss 3 Power up the switch to be initially configured and wait until it has finished its start up processes 4 Connect the PC to any port on the switch using a standard Ethernet cable and check the port...

Страница 6: ...in link act speed mode PoE Mode LED The PoE Mode LED indicates the port status LEDs are displaying in PoE mode Port Status LEDs The Port Status LEDs indicate the current status of each port in either...

Страница 7: ...0 Mbps Off The port has no active network cable connected or has not established a link to connected device Otherwise the port may have been disabled through the switch user interface LED Color State...

Страница 8: ...nt port in order to identify if it is related to the cable or specific port 4 Check if the port is disabled in the configuration settings via web user interface Port Status LED is OFF when the PoE LED...