background image

Quick Start Guide, 61200740L1-13A, March 2006

Technical Support 1-888-4ADTRAN (1-888-423-8726)

Copyright © 2006 ADTRAN, All Rights Reserved

For more detailed documentation, visit us online at 

www.adtran.com

.

Quick Start Guide

®

NetVanta 1355 PWR

P/N 1200740L1

P

OWER

 

OVER

 E

THERNET

Power over Ethernet (PoE) technology provides the ability to detect attached Powered Devices 
(PDs) and deliver 48 VDC to the PD via existing CAT5 cabling. The NetVanta 1355 PWR units are 
fully compliant with the power delivery options called out in the IEEE 802.3af Power over Ethernet 
specification. By default, the PoE interfaces discover and provide power to IEEE compliant PDs. 

To disable power detection and supply, use the

 power inline never

 command in the CLI. To disable 

power detection and supply from the GUI, select the 

Ports

 page. Then select a single port from the 

list (e.g., 

eth 0/1

). This will bring up the port detail page for 

eth 0/1

. On this page, there is a check 

box to enable power detection.

G

ETTING

 S

TARTED

Two configuration methods are available for your NetVanta 1355 PWR unit:

Web-based GUI

AOS Command Line Interface (CLI)

The GUI lets you configure the main unit settings and provides online guidance and explanations for 
each setting. However, using the AOS CLI may be necessary for more advanced configurations. 

A

CCESS

 

THE

 GUI

You can access the web-based GUI from any web browser on your network by following these 
steps:

1.

Connect the unit to your PC using the Ethernet (

ETH 0/0

) port on the rear of the unit.

2.

Set your PC to obtain an IP address automatically via Dynamic Host Configuration Protocol 
(DHCP), or change your PC to a fixed IP address of 

10.10.10.2

. If you cannot change the PC’s 

IP address, you will need to change the unit’s IP address using the CLI. (Refer to the next two 
sections for instructions.)

3.

Enter the unit’s IP address in your browser address line. The default IP address is 

10.10.10.1

.

4.

You will then be prompted for the username and password (the default settings are 

admin

 and 

password

).

5.

The initial GUI screen appears.

N

ET

V

ANTA

 1355 PWR F

RONT

 P

ANEL

 L

AYOUT

A

CCESS

 

THE

 CLI

Access the AOS CLI via the 

CONSOLE

 port or a Telnet session. To establish a connection to the 

NetVanta unit’s 

CONSOLE

 port, you need the following items:

VT100 terminal or PC (with VT100 terminal emulation software)

Straight-through serial cable with a DB-9 (male) connector on one end and the appropriate 
interface for your terminal or PC communication port on the other end

1.

Connect the DB-9 (male) connector of your serial cable to the 

CONSOLE

 port on the rear 

panel of the unit.

2.

Connect the other end of the serial cable to the terminal or PC.

3.

Insert the connector of the provided power cord into the power interface on the rear panel of 
the unit, and plug the cord into a standard electrical outlet.

4.

Once the unit is powered up, open a VT100 terminal session using the following settings: 
9600 baud, 8 data bits, no parity bits, and 1 stop bit. Press 

<Enter>

 to activate the AOS CLI.

5.

Enter 

enable

 at the 

>

 prompt. Enter the enable password when prompted. The default 

password is 

password

.

The configuration parameters used in the examples outlined in this 
document are for instructional purposes only. Please replace all 
underlined entries (

example

) with your specific parameters to configure 

your application.