background image

NetVanta 1224STR DC Hardware Installation Guide

 Option Modules

61200590E1-34B

Copyright © 2013 ADTRAN, Inc.

29

NetVanta SHDSL NIM, Annex B (P/N 1200937E1)

The NetVanta SHDSL NIM, Annex B (shown in 

Figure 12

) provides a WAN SHDSL interface for the 

NetVanta. See 

Table A-10 on page 46

 for the SHDSL connector pinouts.

Figure 12.  NetVanta SHDSL NIM, Annex B

WAN-SHDSL

ANNEX B

Features and Specifications

Operating Mode

Line termination (CO)

Network termination (CPE)

SHDSL Interface

Supported Standards: ITU-T G.991.2 
SHDSL, Annex B
M-pair bonding of 2 pairs - ITU.T 
G.991.2

Line Rate (2-wire mode): 192 to 
2304 kbps in 64k increments

Line Rate (4-wire mode): 384 to 
4608 kbps in 128k increments

Payload: ATM (AAL5)

Line Code: TC-PAM

Connector: RJ-45

Clock Source 

CPE Operating Mode: Network

CO Operating Mode: Internal

Diagnostics

Network loopbacks (local and remote)

Alarm generation and detection

Programmable alarm threshold setting for 
loop attenuation and signal-to-noise ratio

Compliance

EMC - se

Electromagnetic 

Compatibility (EMC) Table on page 6 

.

AS/ACIF  S043

EN 60950

AS/NZS 60950

RoHS compliant (Telecommunications 
exemption)

Environmental

Operating Temperature: 0°C to 50°C

Storage Temperature: -20°C to 70°C

Relative Humidity: Up to 95 percent, 
noncondensing 

Physical

Dimensions: 2.75-inch W x 4.25-inch D

Содержание NetVanta 1224STR PWR

Страница 1: ...erface Module 1200868E1 L1 NetVanta E1 FE1 Network Interface Module 1200878E1 L1 NetVanta E1 FE1 G 703 Drop Network Interface Module 1200866E1 NetVanta Serial Network Interface Module 1200936E1 NetVanta SHDSL Network Interface Module Annex A 1200937E1 NetVanta SHDSL Network Interface Module Annex B 1202869E1 NetVanta ADSL Network Interface Module Annex A 1202889E1 NetVanta ADSL Network Interface M...

Страница 2: ...f this publication Software Licensing Agreement Each ADTRAN product contains a single license for ADTRAN supplied software Pursuant to the Licensing Agreement you may a use the software on the purchased ADTRAN device only and b keep a copy of the software for backup purposes This Agreement covers all software installed on the system as well as any software available on the ADTRAN website In additi...

Страница 3: ...1 34B Copyright 2013 ADTRAN Inc 3 Conventions Notes provide additional useful information Cautions signify information that could prevent service interruption or damage to the equipment Warnings provide information that could prevent injury or endangerment to human life ...

Страница 4: ...e They may explode Check with local codes for special disposal instructions 5 The socket outlet shall be installed near the equipment and shall be easily accessible If any of the following conditions occur unplug the product from the electrical outlet and replace the part or contact your qualified service personnel 1 The power cable extension cable or plug is damaged 2 An object has fallen into th...

Страница 5: ...tioning 5 This unit contains no user serviceable parts 6 This equipment is designed to connect to the telephone network or premises wiring using an FCC compatible modular jack which is compliant with Part 68 and requirements adopted by ACTA 7 The following information may be required when applying to the local telephone company for leased line facilities 8 The ringer equivalency number REN is usef...

Страница 6: ...ference at his own expense Electromagnetic Compatibility EMC Table NetVanta Module P N and Name NetVanta 1224STR DC 1200861L1 56K 64K NIM FCC Part 15 Class A EN 55022 Class A 1200862L2 NEBS T1 FT1 NEBS NIM FCC Part 15 Class A EN 55022 Class A GR 1089 CORE Sections 2 and 3 1202862L1 1202863L1 1200872L1 T1 FT1 NIM T1 FT1 DSX 1 NIM Dual T1 NIM FCC Part 15 Class A EN 55022 Class A 1200868E1 L1 1200878...

Страница 7: ...maximum number of terminals that can be connected to a telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices should not exceed five 5 Canadian Emissions Requirements This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out ...

Страница 8: ...IZED ILLEGAL OR IMPROPER USE OF ADTRAN EQUIPMENT OR SOFTWARE THEREFORE ADTRAN IS NOT LIABLE FOR ANY LOSSES OR DAMAGES RESULTING FROM SUCH FRAUD ATTACK OR IMPROPER USE INCLUDING BUT NOT LIMITED TO HUMAN AND DATA PRIVACY INTELLECTUAL PROPERTY MATERIAL ASSETS FINANCIAL RESOURCES LABOR AND LEGAL COSTS Ultimately the responsibility for securing your telecommunication and networking equipment rests with...

Страница 9: ...ntents 16 Front Panel Design 17 Rear Panel Design 17 Option Modules 19 Network Interface Modules 20 Dial Backup Interface Modules 32 Unit Installation 35 Tools Required 35 Mounting Options 36 Supplying Power to the Unit 38 Installing Dial Backup and Network Interface Modules 39 Installing the NetVanta VPN Accelerator Card included in P N 4200368L1 41 Appendix A Connector Pin Definitions 43 ...

Страница 10: ...Table of Contents NetVanta 1224STR DC Hardware Installation Guide 10 Copyright 2013 ADTRAN Inc 61200590E1 34B ...

Страница 11: ...l T1 NIM 24 Figure 8 NetVanta E1 FE1 NIM 25 Figure 9 NetVanta E1 FE1 G 703 Drop NIM 26 Figure 10 NetVanta Serial NIM 27 Figure 11 NetVanta SHDSL NIM Annex A 28 Figure 12 NetVanta SHDSL NIM Annex B 29 Figure 13 NetVanta ADSL NIM Annex A 30 Figure 14 NetVanta ADSL NIM Annex B 31 Figure 15 Wallmount Installation 37 Figure 16 Grounding the NetVanta 1224STR DC 39 Figure 17 Installing DIMs 40 Figure 18 ...

Страница 12: ...List of Figures NetVanta 1224STR DC Hardware Installation Guide 12 Copyright 2013 ADTRAN Inc 61200590E1 34B ...

Страница 13: ...net Port Pinouts 44 Table A 5 WAN DDS Connector Pinouts 45 Table A 6 WAN T1 Connector Pinouts 45 Table A 7 WAN E1 Connector Pinouts 45 Table A 8 DSX 1 Connector Pinouts 46 Table A 9 G 703 Connector Pinouts 46 Table A 10 WAN SHDSL Connector Pinouts 46 Table A 11 WAN ADSL Connector Pinouts 47 Table A 12 Serial to Cable Connector Pinouts 47 Table A 13 Analog Modem and ISDN BRI DBU Connector Pinouts 4...

Страница 14: ...List of Tables NetVanta 1224STR DC Hardware Installation Guide 14 Copyright 2013 ADTRAN Inc 61200590E1 34B ...

Страница 15: ...e SFP slot for fiber connectivity This section includes a list of features and specifications a list of shipping contents and a description of the unit s front and rear panel designs For additional information refer to the following sections Mounting Options on page 36 Supplying Power to the Unit on page 38 Installing Dial Backup and Network Interface Modules on page 39 Installing the NetVanta VPN...

Страница 16: ...866E1 Serial NIM 1200936E1 SHDSL NIM Annex A 1200937E1 SHDSL NIM Annex B 1202869E1 ADSL NIM Annex A 1202889E1 ADSL NIM Annex B 1200864L1 Analog Modem DIM 1200865L1 ISDN BRI DIM 1200875L1 ISDN S T DIM SFP Module Slots The NetVanta 1224STR DC supports one SFP slot It accepts a number of industry standard SFP modules The SFP modules provide Gigabit Ethernet fiber connectivity for high speed uplinks o...

Страница 17: ...flects the status of an installed DIM The STAT LED indicates the unit s status 10 100Base T Ethernet Interfaces The NetVanta 1224STR DCs contain 24 10 100Base T Ethernet interfaces RJ 45 These interfaces are consecutively numbered 1 through 24 from left to right with the numbers screened directly above each port Status LEDs for each of these interfaces are located directly over these numbers Gigab...

Страница 18: ...Green flashing On power up the STAT LED flashes rapidly for five seconds during which time the user may escape to boot mode from the CONSOLE port Red solid Power is on but the self test failed or the boot code could not be booted DBU Off No DIM is installed Green solid DIM is ready For the ISDN BRI DIM green solid indicates that the negotiation with the switch is complete Green flashing Unit is in...

Страница 19: ...Vanta E1 FE1 G 703 Drop NIM P N 1200878E1 L1 on page 26 NetVanta Serial NIM P N 1200866E1 on page 27 NetVanta SHDSL NIM Annex A P N 1200936E1 on page 28 NetVanta SHDSL NIM Annex B P N 1200937E1 on page 29 NetVanta ADSL NIM Annex A P N 1202869E1 on page 30 NetVanta ADSL NIM Annex B P N 1202889E1 on page 31 DIMs are plug on cards that plug directly on to the NIM prior to installation into the base u...

Страница 20: ...IM is required for dial backup applications Figure 3 NetVanta 56K 64K NIM Features and Specifications Operating Modes Dedicated DDS leased line DDS Interface Supported Standards AT T TR 62310 4 wire full duplex Receiver Sensitivity 45 dB all rates Data Rates 56K 64K and auto Connector RJ 48S Clock Source Network Internal Diagnostics CSU and DSU Loopbacks Compliance EMC see Electromagnetic Compatib...

Страница 21: ... TR 65016 ANSI T1 403 Bellcore TR 194 Line Rate 1 544 Mbps 75 bps Line Code AMI or B8ZS Framing D4 SF or ESF FT1 Line Rate DS0 channelized multiples of 64 kbps Input Signal 0 to 36 dB DS1 Line Build Out 0 7 5 15 22 5 dB long 0 to 655 ft short DS0 Assignment Programmable Connector RJ 48C Clock Source Network Internal Diagnostics Test Pattern Generation and Detection 511 QRSS all ones all zeros Netw...

Страница 22: ...T TR 62411 AT T TR 65016 ANSI T1 403 Bellcore TR 194 Line Rate 1 544 Mbps 75 bps Line Code AMI or B8ZS Framing D4 SF or ESF FT1 Line Rate DS0 channelized multiples of 64 kbps Input Signal 0 to 36 dB DS1 Line Build Out 0 7 5 15 22 5 dB long 0 to 655 ft short DS0 Assignment Programmable Connector RJ 48C Clock Source Network Internal Diagnostics Test Pattern Generation and Detection QRSS 511 215 1 22...

Страница 23: ...F FT1 Line Rate DS0 channelized multiples of 56 64 kbps Input Signal 0 to 36 dB DS1 Line Build Out 0 7 5 15 22 5 dB long 0 to 655 ft short DS0 Assignment Programmable Connector RJ 48C DSX 1 Interface Line Interface DSX 1 per ANSI T1 102 DSX Receiver Input Range 10 dBdsx to 6 dBdsx Line Rate 1 544 Mbps Capacity 1 to 24 DS0s Line Codes AMI B8ZS DSX 1 Interface to PBX Framing D4 SF or ESF Line Length...

Страница 24: ... 194 Line Rate 1 544 Mbps 75 bps Line Code AMI or B8ZS Framing D4 SF or ESF FT1 Line Rate DS0 channelized multiples of 64 kbps Input Signal 0 to 36 dB DS1 Line Build Out 0 7 5 15 22 5 dB long 0 to 655 ft short DS0 Assignment Programmable Connector RJ 48C Clock Source Network Internal Through Diagnostics Test Pattern Generation and Detection QRSS 511 215 1 220 1 all ones all zeros Network loopbacks...

Страница 25: ... E1 Interface Supported Standards ITU G 703 ITU T G 704 CRC 4 ITU T G 823 ITU T G 797 Line Rate 2 048 Mbps 50 PPM Line Code AMI or HDB3 Framing FAS with optional CRC 4 FE1 Line Rate Channelized timeslot in multiples of 64 kbps Receiver Sensitivity 30 dB Connector RJ 48C Clock Source Network Internal Diagnostics Test Pattern Generation and Detection QRSS 511 all ones all zeros Network loopbacks Net...

Страница 26: ...U G 703 ITU T G 704 CRC 4 ITU T G 823 ITU T G 797 Line Rate 2 048 Mbps 50 PPM Line Code AMI or HDB3 Framing FAS with optional CRC 4 FE1 Line Rate Channelized timeslot in multiples of 64 kbps Receiver Sensitivity 30 dB Connector RJ 48C G 703 Interface Receiver Sensitivity 30 dB Line Rate 2 048 Mbps 50 PPM Line Code AMI or HDB3 Framing FAS with optional CRC 4 Capacity 1 to 31 timeslots Connector RJ ...

Страница 27: ...inouts An optional DIM is required for dial backup applications Figure 10 NetVanta Serial NIM Cable length for the Serial NIM should not exceed 25 feet SERIAL DBU Features and Specifications Operating Mode DTE only Serial Interface Supported Standards ISO 4903 X 21 CCITT V 35 Synchronous V 35 EIA 530 Synchronous Provides V 35 X 21 V 11 or EIA 530 electrical interface Connector 26 pin smart serial ...

Страница 28: ...pairs ITU T G 991 2 Line Rate 2 wire mode 192 to 2304 kbps in 64k increments Line Rate 4 wire mode 384 to 4608 kbps in 128k increments Payload ATM AAL5 Line Code TC PAM Connector RJ 45 Clock Source CPE Operating Mode Network CO Operating Mode Internal Diagnostics Network loopbacks local and remote Alarm generation and detection Programmable alarm threshold setting for loop attenuation and signal t...

Страница 29: ...rs ITU T G 991 2 Line Rate 2 wire mode 192 to 2304 kbps in 64k increments Line Rate 4 wire mode 384 to 4608 kbps in 128k increments Payload ATM AAL5 Line Code TC PAM Connector RJ 45 Clock Source CPE Operating Mode Network CO Operating Mode Internal Diagnostics Network loopbacks local and remote Alarm generation and detection Programmable alarm threshold setting for loop attenuation and signal to n...

Страница 30: ...ace ADSL over POTS Annex A Supported Standards ITU G 992 1 G dmt ITU G 992 2 G lite ITU G 992 3 ADSL2 G dmt bis ITU G 992 5 ADSL2 ANSI T1 413 Issue 2 Reach Extended ADSL READSL2 Connector RJ 11C 6 pin jack inner pair ATM Multiple Protocol over AAL5 RFC 2684 PPP over ATM RFC 2364 PPP over Ethernet RFC 2516 ATM Forum UNI 3 1 4 0 PVC ATM Class of Service UBR ATM F5 OAM Up to 16 Virtual Circuits Compl...

Страница 31: ...res and Specifications ADSL Interface ADSL over ISDN Annex B Supported Standards ITU G 992 1 G dmt Connector RJ 11C 6 pin jack inner pair ATM Multiple Protocol over AAL5 RFC 2684 PPP over ATM RFC 2364 PPP over Ethernet RFC 2516 ATM Forum UNI 3 1 4 0 PVC ATM Class of Service UBR ATM F5 OAM Up to 16 Virtual Circuits Compliance EMC see Electromagnetic Compatibility EMC Table on page 6 AS ACIF S043 EN...

Страница 32: ...nstalling Dial Backup and Network Interface Modules on page 39 Features and Specifications Features Supported Standards ITU V 90 Async Compliance EMC see Electromagnetic Compatibility EMC Table on page 6 ACTA FCC Part 68 IC CS 03 UL CUL 60950 Environmental Operating Temperature 0 C to 50 C Storage Temperature 20 C to 70 C Relative Humidity Up to 95 percent noncondensing Physical Dimensions 2 5 inc...

Страница 33: ...p and Network Interface Modules on page 39 Features and Specifications Features Clear channel and bonding mode 1 call protocols Network support for 64 kbps 1 B channel or 128 kbps 2 B channels D channel switch compatibility with AT T 5ESS Northern Telecom DMS 100 and National ISDN 1 V 54 network loopback support Compliance EMC see Electromagnetic Compatibility EMC Table on page 6 ACTA FCC Part 68 ...

Страница 34: ... on page 39 Features and Specifications Features Clear channel and bonding mode 1 call protocols Network support for 64 kbps 1 B channel or 128 kbps 2 B channels D channel switch compatibility with AT T 5ESS Northern Telecom DMS 100 National ISDN 1 and Euro ISDN V 54 network loopback support Compliance EMC see Electromagnetic Compatibility EMC Table on page 6 AS ACIF S031 ETSI TBR 3 EN 60950 IEC 6...

Страница 35: ...X 1 cable T1 FT1 DSX 1 module only DBU cable dial backup functions require an optional DIM Phillips head screwdriver rack mounted applications only To prevent electrical shock do not install equipment in a wet location or during a lightning storm The NetVanta 1224STR DC is intended to be installed maintained and serviced by qualified service personnel only and should be installed in a restricted a...

Страница 36: ...nt in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised Be careful not to compromise the stability of the equipment mounting rack when installing this product Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading the circuit might have on overcurrent protection and suppl...

Страница 37: ...e NetVanta Step Action 1 Remove the mounting ears Rotate them 90 degrees so that the portion of the bracket with the mounting holes is flush with the bottom of the chassis Reattach the mounting ears to the chassis see Figure 15 2 Decide on a location for the NetVanta Keep in mind that the unit needs to be mounted at or below eye level so that the LEDs are viewable 3 Prepare the mounting surface by...

Страница 38: ... NetVanta 1224STR DC System must be from a reliably grounded 24 or 48 VDC Use only copper conductors when making power connections Install unit in accordance with the requirements of NEC NFPA 70 The branch circuit overcurrent protection shall be a fuse or circuit breaker rated minimum 48 VDC maximum 10 A A readily accessible disconnect device that is suitably approved and rated shall be incorporat...

Страница 39: ...ith outside plant connections ensure that all cables are removed from the module before installing or removing it from the NetVanta chassis Always remove power from the unit prior to removing or installing a module Improper installation may result in damage to the modules Electronic modules can be damaged by static electrical discharge Before handling modules put on an antistatic discharge wrist s...

Страница 40: ...of the NIM front panel and slide the module out of the chassis 3 Carefully align the P1 connector on the NIM with the J1 connector on the DIM Using only fingertip pressure so that neither circuit board bends or flexes ensure that the connectors are firmly seated Secure the DIM to the NIM using the screws and standoff posts supplied See Figure 17 4 Slide the NIM with the DIM attached into the NetVa...

Страница 41: ...S and 422 Mbps AES The power consumption of the card does not exceed 2 watts Instructions for Installing the NIMs Step Action 1 Remove power from the unit 2 Use a screwdriver to remove the cover plate from the appropriate option slot in the NetVanta base unit 3 Slide the option module into the option slot until the module is firmly seated against the chassis 4 Secure the pins at both edges of the ...

Страница 42: ...uments are also available online on ADTRAN s Support Forum Instructions for Installing the NetVanta VPN Accelerator Card Step Action 1 Remove power from the unit 2 Remove the screws holding the base unit and the cover together and if necessary two mounting brackets see Figure 19 3 Using a 3 16 inch hex driver remove the two jack screws located on either side of the DB 9 port 4 Carefully lift and r...

Страница 43: ... Carrier Detect output 2 RD Receive Data output 3 TD Transmit Data input 4 DTR Data Terminal Ready input 5 SG Signal Ground 6 DSR Data Set Ready Tied to pin 1 output 7 Unused 8 CTS Clear to Send Tied to pin 1 output 9 Unused Table A 2 SFP Slot Pinouts Pin Name Pin Name 1 TGND 11 RGND 2 TX FAULT 12 RX 3 TX DISABLE 13 RX 4 MOD DEF 2 14 RGND 5 MOD DEF 1 15 VccR 6 MOD DEF 0 16 VccT 7 RATE SELECT 17 TG...

Страница 44: ...X2 Transmit Negative 3 RX1 Receive Positive 4 5 Unused 6 RX2 Receive Negative 7 8 Unused Table A 4 1000Base T Gigabit Ethernet Port Pinouts Pin Name Description 1 TRD0 Transmit Receive Positive 2 TRD0 Transmit Receive Negative 3 TRD1 Transmit Receive Positive 4 TRD2 Transmit Receive Positive 5 TRD2 Transmit Receive Negative 6 TRD1 Transmit Receive Negative 7 TRD3 Transmit Receive Positive 8 TRD3 T...

Страница 45: ...e network Tip 8 R Receive data from the network Ring Table A 6 WAN T1 Connector Pinouts Pin Name Description 1 R1 Receive data from the network Ring 1 2 T1 Receive data from the network Tip 1 3 Unused 4 R Transmit data toward the network Ring 5 T Transmit data toward the network Tip 6 8 Unused Table A 7 WAN E1 Connector Pinouts Pin Name Description 1 R1 Receive data from the network Ring 1 2 T1 Re...

Страница 46: ...Unused 4 R1 Receive data from the DTE Ring 1 5 T1 Receive data from the DTE Tip 1 6 8 Unused Table A 9 G 703 Connector Pinouts Pin Name Description 1 R Transmit data toward the DTE Ring 2 T Transmit data toward the DTE Tip 3 Unused 4 R1 Receive data from the DTE Ring 1 5 T1 Receive data from the DTE Tip 1 6 8 Unused Table A 10 WAN SHDSL Connector Pinouts Pin Name Description 1 T2 Loop 2 Tip 2 R2 L...

Страница 47: ...e A 12 Serial to Cable Connector Pinouts Serial Pin V 35 Pin X 21 Pin EIA 530 Pin Name 1 P 2 2 TD_A 2 U N A 24 ETC_A 3 Y N A 15 TCLK_A 4 V 6 17 RCLK_A 5 R 4 3 RD_A 6 F N A 8 DCD_A 7 H N A 20 DTR_A 8 C 3 4 RTS_A 9 N A 10 19 RTS_B V 11 only 10 N A 12 13 CTS_B V 11 only 11 D 5 5 CTS_A 12 E N A 6 DSR_A 13 K N A 25 TM_A 14 S 9 14 TD_B 15 W N A 11 ETC_B 16 AA N A 12 TCLK_B 17 X 13 9 RCLK_B 18 T 11 16 RD...

Страница 48: ...n optional DIM is required for dial backup applications Table A 13 Analog Modem and ISDN BRI DBU Connector Pinouts Pin Name Description 1 3 Unused 4 R Network Ring 5 T Network Tip 6 8 Unused Table A 14 ISDN S T DBU Connector Pinouts Pin Name Description 1 2 Unused 3 R1 Network Receive Ring 1 4 R Network Transmit Ring 5 T Network Transmit Tip 6 T1 Network Transmit Tip 1 7 8 Unused ...

Отзывы: