NetVanta 1000 Series Switch Hardware Installation Guide
Option Modules
61200500L1-34C
© 2004 ADTRAN, Inc.
29
NetVanta Dual T1 NIM (P/N 1200872L1)
The NetVanta Dual T1 NIM (see Figure 10) provides two WAN T1 interfaces for the NetVanta. Refer to
Table A-6 on page 43 for the pinouts. Refer to Table A-11 on page 46 for the DBU connector pinout. An
optional DIM is required for dial backup applications.
Figure 10. NetVanta Dual T1 NIM
Features and Specifications
Operating Modes
•
T1/ FT1
T1 Interface
•
Line Rate: 1.544 Mbps +/- 75 bps
•
Line Code: AMI or B8ZS
•
Framing: D4 (SF) or ESF
•
FT1 Line Rate: DS0 Channelized
(multiples of 64 kbps)
•
Input Signal: 0 to -36 dB (DS-1)
•
Line Build-Out: 0, -7.5, -15, -22.5 dB
•
Connector: RJ-48C
•
DS0 Assignment: Programmable
Clock Source
•
Network
•
Internal
•
Through
Diagnostics
•
Test pattern generation and detection:
QRSS, 2
15
-1, 2
20
-1, 511
•
Network loopbacks (local and remote)
•
Responds to both inband and FDL loop
codes
•
Alarm generation detection
•
Network performance data (15 minutes
and 24 hours)
Relevant Requirements/Standards
•
EMC - see
Compatibility (EMC) Table for the
NetVanta 1224STR/1224R
•
ACTA/FCC Part 68
•
Industry Canada CS03
•
UL and CUL
•
T1 Interface: Pub 62411
•
ESF Format Interface: TR. 194
•
ESF Performance Monitoring: TR. 54016
and T1.403
Environmental
•
Operating temperature: 0 °C to 50 °C
•
Storage Temperature: -40 °C to 85 °C
•
Relative Humidity: Up to 95%
noncondensing
Physical
•
Dimensions: 4.25” x 2.75”
Содержание NetVanta 1000 Series
Страница 14: ...Table of Contents NetVanta 1000 Series Switch Hardware Installation Guide 14 2004 ADTRAN Inc 61200500L1 34C ...
Страница 16: ...List of Figures NetVanta 1000 Series Switch Hardware Installation Guide 16 2004 ADTRAN Inc 61200500L1 34C ...
Страница 18: ...List of Tables NetVanta 1000 Series Switch Hardware Installation Guide 18 2004 ADTRAN Inc 61200500L1 34C ...
Страница 48: ...Index NetVanta 1000 Series Switch Hardware Installation Guide 48 2004 ADTRAN Inc 61200500L1 34C ...