background image

PRICING AND AVAILABILITY  800.827.0807

TECH SUPPORT  800.726.8663

RETURN FOR REPAIR  256.963.8722

www.adtran.com

61186002L5-22A

Warranty

:ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. 

Warranty information can be found at 

www.adtran.com/warranty

.

1. Configuration

2. Provisioning

3. Status

4. Test

5. Performance Monitoring

To/from SCU menus

4. Protection

Note: An asterisk (*) indicates default setting

5. Save Provisioning

1. 0-133 ft*

T1:

E1:

3. 266-399 ft

2. 133-266 ft

5. 533-655 ft

1. 0-6dB Loss

4. 399-533 ft

1. 2 seconds*

29. Set Multiple

30. Auto Enable Delay

3. 2 hours

2. 1 hour

5. 1 day

4. 12 hours

6. 2 days

7. 7 days

1. Disabled   

3. 5 Minutes*   

2. 1 Minute          

5. 15 Minutes   

4. 10 Minutes   

6. 30 Minutes   
7. 45 Minutes  
8. 60 Minutes   

1. Near End Daily

3. Far End Daily

2. Near End Quarter Hourly 

5. Near End Daily Thresholds 

4. Far End Quarter Hourly 

6. Near End Quarter Hourly Thresholds 
7. Near End Daily Thresholds 
8. Near End Quarter Hourly Thresholds

1. Data Mode

3. Digital Loopback

2. Line Loopback

5. Remote ALL T1/E1

4. Remote Loopback

1. QRSS

3. ALL ZEROES

2. ALL ONES

5. 1 in 8 (1:7)

4. 2 in 8 (2:6)

6. 2 ^15-1 INV

1. Data Mode

2. Network Loopback 

1. Data Mode

T1:

3. Analog Network

2. Tributary

5. CODEC Line/Net

4. Digital Line/Net

6. Remote Loopback
7. CSU Loopback
8. CSU LB w/BERT

9. NIU Loopback

10. NIU LB w/BERT

11. Line BERT 

1. Data Mode

E1:

T1/E1 Loopbacks (T1/E1 #1-28)

29. DS3 Loopbacks

3. Analog Network

2. Tributary

5. CODEC Line/Net

4. Digital Line/Net

6. Remote Loopback
7. Line BERT

CLEI Code

Serial Number

Part Number

Code Checksum

Code Version

Boot Version
Boot Checksum
Self Test

1. Disabled*

3. 1E-4

2. 1E-3

5. 1E-6

4. 1E-5

1. Disabled*

3. 1E-4

2. 1E-3

5. 1E-6

4. 1E-5

1. Near End Daily

3. Near End Daily Thresholds 

2. Near End Quarter Hourly 

4. Near End Quarter Hourly Thresholds 

1. Disabled

3. FEAC

2. FEAC/C-BIT*

4. C-BIT

1. DS3 Framing

3. DS3 Remote Loopbacks

2. DS3 Timing

5-11. DS2 Mode (DS2 #1-7)

4. DS3 XCV Threshold

1. T1/E1 State

3. T1/E1 Line Length

2. T1/E1 Line Coding

5. T1/E1 Circuit Protection

4. T1/E1 Loopback Detection

6. T1/E1 Line Identification

7. T1/E1 XCV Threshold

(T1/E1 #1-28)

(T1/E1 #1-28)

(T1/E1 #1-28)

(T1/E1 #1-28)

(T1/E1 #1-28)

(T1/E1 #1-28)

(T1/E1 #1-28)

7. Card Reset

1. Network Interface

2. T1/E1 Interfaces

3. Service States 

6. Restore Factory Defaults

8. Auto Save

9 . Loopback Timeout

10 . Card Pair ID

1. AMI

2. B8ZS/HBD3*

1. Disabled

2. Enabled

3. Auto Enable*

T1/E1 #1-28

29. DS3

30. Set Multiple

1. Card 1A

2. Card 1B

3. Facility Service States

2. Enabled*

1. Disabled

30. Protection Threshold (1-28): 1*

2. Enabled*

1. Disabled

1. Disabled*

2. CSU (T1 Only)

3. NIU (T1 Only)

1. Perform Manual Switch

2. Minimum Switching Period (sec.) (10*)

3. Maximum Switch Threshold (3*)

1. DS3 Statistics

2. T1/E1 Statistics

3. Clear ALL Statistics

1. M12 (4xT1)*

2. G.747 (3xE1)

1. C-BIT

2. M13*

1. IS

2. OOS

1. Loop

2. Local*

30-36. DS2 #1-7 Loopbacks

37. Reset ALL Tests

38. Pattern

12. DS3 Equipment Identification

MX2820 –48 VDC M13 MUX

Отзывы: