Step 1: Install the Base and Connect Fiber
Ensure the 424RG3 ONT is not located in direct sunlight and is not
located next to any thermal obstructions. To attach the 424RG3 ONT
to the base, refer to
and complete the following steps:
1. Remove the two screws from the base of the 424RG3 ONT.
2. Position the 424RG3 ONT on the base.
3. Using the two screw provided, secure the base to the 424RG3
ONT.
4. Thread the fiber cable through the opening in the base. If there
is excess fiber, carefully wrap it around the Fiber Tray.
5. Remove the dust cover from the SC/APC Connector and insert
the fiber cable. Retain the dust cover and insert it in the fiber
connection when the fiber cable is not connected. This will
protect the optical portion of the connection.
illustrates the 424RG3 ONT after the base has been attached.
Figure 1. Attach 424RG3 ONT to Base and Connect Fiber
Figure 2. 424RG3 ONT with Base Attached
Screw
Fiber
Tray
SC/APC
Connector
Fiber
Opening
Screw
1
2
3
4
2.4
5.0
1
2
WiFi
The 424RG3 ONT provides 802.11b/g/n/ac compliant WiFi that
support both 2.4 GHz and 5.0 GHz.
USB
There is a USB data connection on the rear of the 424RG3 ONT that
can be used for connection and communications with other
computers and electronic devices.
I
NSTALLATION
After unpacking the 424RG3 ONT, inspect it for damage. If damage is
noted, file a claim with the carrier and then contact ADTRAN. For
more information, refer to the warranty.
Installation consists of positioning the 424RG3 ONT on a desktop and
connecting POTS (PHONE), Ethernet, Fiber, and power.
Installation Guidelines
The following are guidelines for this installation.
■
Read all warnings and cautions before installing or servicing the
424RG3 ONT.
■
Do not place the 424RG3 ONT in direct sunlight or next to any
thermal obstructions.
Installation Overview
To install the 424RG3 ONT, you will need to complete the following
steps:
■
“Step 1: Install the Base and Connect Fiber”
■
“Step 2: Connect POTS (PHONE)”
■
■
■
“Step 5: Connect UPS (optional)”
Required tools
Standard technician tools and those listed below are required for
installing the 424RG3 ONT:
■
Phillips-head screwdriver
■
Two, RJ-11 connectors
■
Four, RJ-45 connectors
■
Wire strippers
■
RJ-11 and RJ-45 crimpers
■
PON power meter with wavelength filtering
■
Fiberscope or videoscope
For fiber optic connections, the following is required:
■
ODC Fiber cleaning tool
Installation Steps
NOTICE
The 424RG3 ONT must sit upright using the stand provided. DO
NOT lay the ONT flat as it may overheat.
To install the 424RG3 ONT, refer to
and complete the
following steps.