background image

PRICING AND AVAILABILITY  800.827.0807

TECH SUPPORT  800.726.8663

RETURN FOR REPAIR  256.963.8722

www.adtran.com

61223424L2-22B

Warranty

: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. 

Warranty information can be found at 

www.adtran.com/warranty

T200 HDSL4 Transceiver Unit, Remote-Local Powered

TROUBLESHOOTING HDSL4

This ADTRAN HDSL4 unit is equipped with troubleshooting-at-a-glance LEDs (identified on the reverse side of 

this document) that provide customers with a simple means of identifying the location of certain faults. 

Additionally, screens available via the craft interface simplify the trouble isolation process. These screens and their 

associated benefits are described below.

Troubleshooting Screen

Available via the Main Menu: provides ADTRAN contact information and access to the Troubleshooting Guidance 

and General Information screens. 

Troubleshooting Guidance Screens

Available via the Troubleshooting screen: detects and displays errors and/or alarms at any of the monitored inputs 

(DSX1, DS1 and HDSL). Guidance on the fault(s) detected includes possible cause(s) and suggested actions, 

including those shown below: 

General Information Screen

Available via the Troubleshooting screen: a reference page which displays the minimum acceptable signal margin, 

maximum attenuation, and other deployment parameters for this HDSL4 circuit. 

NOTE: Along with the Troubleshooting screens, the Detailed Status screen and Performance History screen, 

available via the craft access terminal, provide both real-time and historical view of this circuit. 
For complete deployment guidelines on the HDSL4 circuit, refer to the Installation and Maintenance 

Practice referenced on the front page.

DSX-1/DS1:

LOS

Loss of signal (Red Alarm) at the DSX-1/DS1 
receiver

CLK

T1 receive clock is out of range

RAI

Remote Alarm Indication (Yellow Alarm) 
detected at DSX-1/DS1 receiver

AIS

Alarm Indication Signal (Blue Alarm) detected 
at DSX-1/DS1 receiver

ERR

Errors recorded at DSX-1/DS1 receiver

Facility:

GROUND Ground Fault on span (facility pair grounded)
SHORT

Short circuit (or low impedance) between pairs

OPEN

Open circuit between facility pairs

DSL:

LOS

Loss of HDSL sync

MARG

Margin has exceeded the alarm threshold

ATTEN

Attenuation has exceeded the alarm threshold

ERR

Errors recorded at the HDSL receiver

HIST

Performance History of the DSL units

ATTENUATION LIMITS

Recommended Maximum

Segment

Upstream

Downstream

1

st

 segment 

30 dB

32 dB

2

nd

 and 3

rd

 segment 

28 dB

28 dB

RANGE LIMITS, PIC Cable, 70°F

Gauge/Segment

Recommended Maximum

26 Gauge, 1

st

 segment

10,470 ft.

26 Gauge, 2

nd

 and 3

rd

 segment

9,865 ft. 

1,2

 

24 Gauge, 1

st

 segment

14,770 ft.

24 Gauge, 2

nd

 and 3

rd

 segment

14,050 ft. 

1,2

 

1

 In three segment circuits (two H4Rs), individual segment resistance values 

must be verified

. Refer to the Installa-

tion and Maintenance Practice for details and calculations.

2

 When designing a dual H4R loop (three segment), the first segment should have lower DC resistance than the 

second segment. 

LOOPBACK CONTROL CODES

Pattern

Description 

Requires 

Arming?

1in3 

Loop down all units and disarm. 

No

2in5 

Arming Pattern, H4TU-R will loop up if Smartjack LB is enabled. 

No

3in5 

Disarm and loop down all units. Restores LB TMO after D5D6. 

No

2in6

H4R1 LB to Network. 

No

3in6

H4R2 LB to Network. 

No

4in6

H4R1 LB to Customer. 

No

5in6

H4R2 LB to Customer. 

No

3in7 

H4TU-R LB to Network. 

No

4in7 

H4TU-C LB to Network. 

No

5in7 

H4TU-R LB to Customer. 

No

6in7 

H4TU-C LB to Customer. 

No

3F1E 

H4TU-C LB to Customer. 

No

3F02 

H4TU-R LB to Customer. 

No

3F04 

H4R1 LB to Customer. 

No

3F06

H4R2 LB to Customer. 

No

3F08

H4R3 LB to Customer

No

6767 

Disable span powering while present. 

Yes

9393 

Loop down H4TU-C, Repeaters – all loopbacks. Loop down H4TU-R – Cust LB always. Will only 
loop down H4TU-R Network LB if NIU is disabled. Does not disarm units if they are armed. 

No

C741 

H4R1 loopback pattern. 10 bit error injection. 

Yes

C742 

H4TU-R loopback pattern. 20 bit error injection. 

Yes

C754 

H4R2 loopback pattern. 200 bit error injection. 

Yes

C743

H4R3 loopback pattern. 30 bit error injection.

Yes

D3D3 

H4TU-C loop up pattern. 231 bit error injection. 

Yes

D5D5 

Query Loopback Pattern (error injection) - H4TU-C: 231 Errors, H4R1: 10 Errors, 

 

H4R2: 200 Errors, H4R3: 30 errors, H4TU-R: 20 Errors

No

D5D6

Loopback Timeout Override: Disables LB timeout. Restores original LB timeout when unit is dis-
armed. 

Yes

FF48

FDL Arming Pattern (ESF only). Arms all units, H4TU-R will LB to Network if NIU Enabled (if 
pattern sources at network). 

No

FF24 

FDL Disarm Pattern (ESF only). Loop down and disarm all units 

No

FF1E 

H4TU-C LB to Network. Will not loop up H4TU-C if H4TU-C already in LB to Customer. 

No

FF02 

H4TU-R LB to Network. Will not loop up H4TU-R if any unit already in LB to Customer. 

No

FF04 

H4R1 LB to Network. 

No

FF06

H4R2 LB to Network. 

No

FF08

H4R3 LB to Network

No

Отзывы: