background image

1

61190852L2-5, Issue 3

61190852L2-5C

Section  61190852L2-5C

Issue 3, December 2001

CLEI # T1TSSRJF _ _

HDSL 852 Central Office Installation Kit

Installation and Maintence

Trademarks:  Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.

1. GENERAL

This practice provides installation and operation
procedures for the ADTRAN HDSL Installation Kit
for the Central Office.  The HDSL CO Installation Kit
is designed for use with the ADTRAN HDSL Remote
Installation Kit, part number 1190851L2.  

Figure 1

 is

an illustration of the HDSL Central Office Installation
Shelf.  This kit can house any standard 220 mechanics
card to include T1, HDSL, and HDSL2.  This practice
is written around the HDSL application.

Revision History

Issue 3 revises order guide tables.

Features

The HDSL Central Office Installation Kit,
P/N 1190852L2, includes the following features:

• Compact construction installation unit.

• Local AC powering.

• Houses a standard E220 CO card, with optional

3192, DDM Plus, and Soneplex adapter inserts.

• Bantam to alligator connections.

• Versatile protective carrying case.

Adapter Inserts

Separately purchased adapter inserts configure the
E220 form factor to accomodate the following
mechanics:

• Insert E220/3192

P/N 1190852L22

FIGURES

Figure 1. HDSL 852 CO Installation Shelf ............. 1
Figure 2. HDSL Circuit Simulation ......................... 2
Figure 3. Front Panel Features ................................. 3
Figure 4. Rear Panel Feature ................................... 3
Figure 5. Pairing CO Installation Kit ....................... 3
Figure 6. Test Cables ............................................... 4
Figure 7. Testing Line Units .................................... 5
Figure 8. Pairing a Circuit ....................................... 5
Figure 9. T1 BERT Testing of an HDSL Circuit .... 6
Figure 10. Adapter Insert Installation ........................ 7

TABLES

Table 1.

Line Units ................................................. 5

Table 2.

Specifications ........................................... 7

Table 3.

Ordering Guide for the 852 CO Shelf ...... 7

Table 4.

Ordering Guide for the 851 Remote
Shelf .......................................................... 7

Figure 1.  HDSL 852 CO Installation Shelf

CONTENTS

1.

GENERAL .......................................................... 1

2.

OPERATION ...................................................... 2

3.

TESTING ............................................................ 5

4.

SPECIFICATIONS ............................................. 7

5.

MAINTENANCE ............................................... 7

6.

WARRANTY AND CUSTOMER SERVICE ... 8

CAUTION:

RISK OF ELECTRICAL

SHOCK.  M

AXIMUM

VOLTAGES UP TO

-200 VDC M

AY BE

PRESENT ON

 TELECOM

CIRCUITS.

1190852L2

HDSL 852 C

O POWER

REMOTE

LP1 LP2

DSX

TX RX

ESD
GND

DSX-1

LBO

B8ZS

FRM
ESF

NIU LB DI

S

LB TIMEO

UT DIS

533

399

266

133

0

EXT

12460

01L2

LBK

ALM

DSX

DSL

TX

RX

TX

RX

M

O

N

E

Q

HTU-C

M

AMI
UFRM
SF
EN
EN

12345

Содержание HDSL 852

Страница 1: ...DM Plus and Soneplex adapter inserts Bantam to alligator connections Versatile protective carrying case Adapter Inserts Separately purchased adapter inserts configure the E220 form factor to accomodate the following mechanics Insert E220 3192 P N 1190852L22 FIGURES Figure 1 HDSL 852 CO Installation Shelf 1 Figure 2 HDSL Circuit Simulation 2 Figure 3 Front Panel Features 3 Figure 4 Rear Panel Featu...

Страница 2: ...repeater selection switch on the remote unit 2 OPERATION After unpacking the unit inspect it for damage If damage is noted file a claim with the carrier then notify ADTRAN See Warranty and Customer Service The CO Installation Kit is shipped complete with the CO shelf softcase power cord and dual bantam to alligator clip cable Front Panel Features The HDSL CO Installation Kit front panel features a...

Страница 3: ...Office Powering Shelf Customer Equipment or NIU HDSL Circuit CAUTION RISK OF ELECTRICAL SHOCK MAXIMUM VOLTAGES UP TO 200 VDC MAY BE PRESENT ON TELECOM CIRCUITS 1190851L2 HDSL 851 REPEATER REMOTE ESD GND RPTR C O CABLE PAIRS RPTR TO REMOTE CABLE PAIRS LP1 LP2 LP1 LP2 REMOTE CABLE PAIRS DS1 LP1 LP2 RX TX RPTR IN OUT CAUTION RISK OF ELECTRICAL SHOCK MAXIMUM VOLTAGES UP TO 200 VDC MAY BE PRESENT ON TE...

Страница 4: ... pairs that form the HDSL circuit The cables are attached depending on the installation as follows For a single pair HDSL installation use a test cable with a single bantam end and two alligator clips Insert the cable s bantam end in the LP1 signal jack and attach each alligator clip to one of the wires in the twisted pair For a two pair HDSL installation use a test cable with a dual bantam end an...

Страница 5: ...e Units 2 Verify that the other required line units are available for the test see Table 1 The required line unit s can either be installed in another HDSL Installation Kit or in an HDSL circuit NOTE Verifythattherequiredlineunitsareoperational before proceeding 3 Install patch cables to make the necessary connections between the line unit being tested and the required line units Figure 7 Testing ...

Страница 6: ...2 LP1 LP2 Customer Equipment HDSL Circuit CAUTION RISK OF ELECTRICAL SHOCK MAXIMUM VOLTAGES UP TO 200 VDC MAY BE PRESENT ON TELECOM CIRCUITS 1190851L2 HDSL 851 REPEATER RE MOTE ESD GND RPTR C O CABLE PAIRS RPTR TO REMOTE CABLE PAIRS LP1 LP2 LP1 LP2 REMOTE CABLE PAIRS DS1 LP1 LP2 RX TX RPTR IN OUT T1 BERT Tester CAUTION RISK OF ELECTRICAL SHOCK MAXIMUM VOLTAGES UP TO 200 VDC MAY BE PRESENT ON TELEC...

Страница 7: ...XIMUM VOLTAGES UP TO 200 VDC MAY BE PRESENT ON TELECOM CIRCUITS 1190852L2 HDSL 852 CO POWER REMOTE LP1 LP2 DS1 TX RX ESD GND s t n e m e r i u q e R r e w o P m e t s y S r e w o P c a V 5 1 1 d e d n u o r G x a M A 5 0 z H 0 6 0 5 0 1 l a t n e m o r i v n E e r u t a r e p m e t g n i t a r e p O e r u t a r e p m e t e g a r o t S C 0 5 o t C º 0 F 2 2 1 o t F º 2 3 C 0 7 o t C º 0 4 F 8 5 1 o...

Страница 8: ...and Product Service CAPS prior to returning equipment to ADTRAN For service CAPS requests or further information contact one of the following numbers ADTRAN Sales Pricing Availability 800 827 0807 ADTRAN Technical Support Pre sales Applications Post sales Technical Assistance 800 726 8663 Standard hours Monday Friday 7 a m 7 p m CST Emergency hours 7 days week 24 hours day ADTRAN Repair CAPS Retur...

Отзывы: