NetVanta E1/FE1 + G.703 Drop Network Interface Module (NIM)
P/N 1200878L1
For more detailed documentation, visit us online at
Quick Start Guide
®
Quick Start Guide, 61200878L1-13D, July 2005
ADTRAN Technical S1-256-963-8716
Copyright © 2005 ADTRAN, All Rights Reserved
S
PECIFICATIONS
Operating Modes
Frame Relay, Multilink Frame Relay,
PPP, Multilink PPP, HDLC
E1/FE1 Interface
Supported Standards: ITU-T G.703, ITU-T G.704 (CRC-4),
ITU-T G.823, ITU-T G.797
Receiver Sensitivity: -30 dB
Line Rate: 2.048 Mbps ±50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
FE1 Line Rate: Channelized timeslot (in multiples of
56/64 kbps)
Connector: RJ-48C
G.703 Interface
Supported Standards: Per ITU-T G.703
Receiver Sensitivity: -30 dB
Line Rate: 2.048 Mbps, ±50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
Capacity: 1 to 31 timeslots
If timeslot 16 signaling is used on the drop port, a maximum
of 15 timeslots can be mapped to router (1 to 15 or 17 to 31).
Connector: RJ-48C
Clock Source
Network, internal, and through
Diagnostics
Test Pattern Generation and Detection: QRSS, 511, all
ones, all zeros
Network loopbacks
Alarm generation and detection
Network performance data (15 minutes and 24 hours)
Compliance
FCC Part 15 Class A, EN 55022 Class A, EN 55024,
EN 61000-3-2, EN 61000-3-3
AS/ACIF S016, ETSI TBR 12/TBR 13
EN 60950, IEC 60950, AS/NZS 60950
Physical
Dimensions: 2.75-inch W x 4.25-inch D
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
WAN-E1
G.703
DBU
I
NSTALLATION
I
NSTRUCTIONS
1.
Remove power from the unit.
2.
Slide the option module into the option slot until the module is
firmly seated against the chassis.
3.
Secure the pins at both edges of the module.
4.
Connect the cables to the associated device(s).
5.
Complete the installation of the base unit.
6.
Restore power to the unit.
NetVanta modules should be installed only in
NetVanta Series products.
WAN-E1 N
ETWORK
(RJ-48C) C
ONNECTION
P
INOUTS
Pin
Name
Description
1
R1
Receive data from the network - Ring 1
2
T1
Receive data from the network - Tip 1
3
—
Unused
4
R
Transmit data toward the network - Ring
5
T
Transmit data toward the network - Tip
6-8
—
Unused
G.703 (RJ-48C) C
ONNECTION
P
INOUTS
Pin
Name
Description
1
R
Transmit data toward the DTE - Ring
2
T
Transmit data toward the DTE - Tip
3
—
Unused
4
R1
Receive data from the DTE - Ring 1
5
T1
Receive data from the DTE - Tip 1
6-8
—
Unused
An optional Dial Backup Interface Module (DIM)
is required for dial backup applications.
For a description of the DBU pinouts, refer to the
Quick Start Guide included with your DIM
shipment.
Important:
For additional details on product
features, specifications, installation, and safety,
refer to the appropriate Hardware Installation
Guide on the
ADTRAN OS System
Documentation
CD shipped with the base unit