S

PECIFICATIONS

Operating Modes

Frame Relay, Multilink Frame Relay, 
PPP, Multilink PPP, HDLC

E1/FE1 Interface

Supported Standards: ITU-T G.703, ITU-T G.704 (CRC-4), 
ITU-T G.823, ITU-T G.797
Receiver Sensitivity: -30 dB
Line Rate: 2.048 Mbps ±50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
FE1 Line Rate: Channelized timeslot (in multiples of 
56/64 kbps)
Connector: RJ-48C

G.703 Interface

Supported Standards: Per ITU-T G.703
Receiver Sensitivity: -30 dB
Line Rate: 2.048 Mbps, ±50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
Capacity: 1 to 31 timeslots
If timeslot 16 signaling is used on the drop port, a maximum 
of 15 timeslots can be mapped to router (1 to 15 or 17 to 31).
Connector: RJ-48C

Clock Source

Network, internal, and through

Diagnostics

Test Pattern Generation and Detection: QRSS, 511, all 
ones, all zeros
Network loopbacks
Alarm generation and detection
Network performance data (15 minutes and 24 hours)

Compliance

FCC Part 15 Class A, EN 55022 Class A, EN 55024, 
EN 61000-3-2, EN 61000-3-3
AS/ACIF S016, ETSI TBR 12/TBR 13
EN 60950, IEC 60950, AS/NZS 60950

Physical

Dimensions: 2.75-inch W x 4.25-inch D
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing

WAN-E1

G.703

DBU

 

I

NSTALLATION

 I

NSTRUCTIONS

1.

Remove power from the unit.

2.

Slide the option module into the option slot until the module is 
firmly seated against the chassis.

3.

Secure the pins at both edges of the module.

4.

Connect the cables to the associated device(s).

5.

Complete the installation of the base unit.

6.

Restore power to the unit.

NetVanta modules should be installed only in 

NetVanta Series products.

WAN-E1 N

ETWORK

 (RJ-48C) C

ONNECTION

 P

INOUTS

Pin

Name

Description

1

R1 

Receive data from the network - Ring 1

2

T1

Receive data from the network - Tip 1

3

Unused

4

Transmit data toward the network - Ring

5

Transmit data toward the network - Tip

6-8

Unused

G.703 (RJ-48C) C

ONNECTION

 P

INOUTS

Pin

Name

Description

1

Transmit data toward the DTE - Ring

2

Transmit data toward the DTE - Tip

3

Unused

4

R1

Receive data from the DTE - Ring 1

5

T1 

Receive data from the DTE - Tip 1

6-8

Unused

An optional Dial Backup Interface Module (DIM) 

is required for dial backup applications.
For a description of the DBU pinouts, refer to the 

Quick Start Guide included with your DIM 

shipment.

Important:

 For additional details on product 

features, specifications, installation, and safety, 

refer to the appropriate Hardware Installation 

Guide on the 

ADTRAN OS System 

Documentation

 CD shipped with the base unit 

and available online at www.adtran.com.

Отзывы: