Total Access 1500

Dual Nx56/64 Data Service Unit Data Port 

(DSU DP)

CONNECTIONS

All connections are made through the double stacked DB-26 
connectors on the faceplate of the Dual Nx56/64. A DB-26 to V.35 
cable (P/N 1200167L1) is available to provide a V.35 interface.

Wiring Connections

COMPLIANCE

The Dual Nx56/64 is intended to be installed in a Restricted Access 
Location.

This device complies with Part 15 of the FCC rules. Operation is 
subject to the following two conditions: (1) This device may not 
cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause 
undesired operation.
Changes or modifications not expressly approved by ADTRAN could 
void the user’s authority to operate this equipment.

DB-26

V.35

Name

Pin

Pin

Name

Frm Gnd

1

A

Frm Gnd

RTS

4

C

RTS

CTS

5

D

CTS

DSR

6

E

DSR

Sig GND

7, 21

B

Sig GND

CD

8

F

CD

TxD A

9

P

TxD A

TxD B

10

S

TxD B

RxD A

11

R

RxD A

RxD B

12

T

RxD B

Ext TxC A

13

U

Ext TxC A

RI

17

J

RI

LL

18

L

LL

TM

19

NN

TM

DTR

20

H

DTR

TxC A

22

Y

TxC A

TxC B

23

AA

TxC B

RxC A

24

V

RxC A

RxC B

25

X

RxC B

Ext TxC B

26

W

Ext TxC B

Configuration Code

Input

Output

Power Code (PC)

C

C

Telecommunication Code (TC)

Installation Code (IC)

A

7. Allocate a range of channels to the Dual Nx56/64.

a. Perform steps 

6a

 through 

6e

.

b. Select the first time slot in the range of time slots that is 

to be assigned to a port of the Dual Nx56/64.

c. Perform steps 

6g

 and 

6h

.

d. Select option 4 to assign a range of DS0s.
e. Enter the range (the range should be entered starting 

with the first DS0, then entering a dash or slash, and 
finally entering the last DS0.)

8. Remove a channel from the Dual Nx56/64.

a. Select the T1 to remove time slots from, at the time slot 

assignment screen.

b. Select the time slot you want to remove.
c. Select option 3 to remove time slot.

NOTE: To remove multiple time slots change the bank mode to single 

T1. The LIU will remove all assigned time slots in use and 

assign all cards in shelf the appropriate time slots depending 

on their position in the shelf.

TESTING

To access the test menu, select the access module menu, then 
select the slot containing the Dual Nx56/64 to test, and finally 
select the test option.

NOTE: The loopbacks are used in conjunction with bit error rate test 

(BERT) equipment.

DTE Loopback

The test loops back the entire data stream from the Dual Nx56/64 
to the DTE.

Provides complete diagnostic picture of the V.35 interface path.

Network Loopback

Data is looped back across the T1.

Test can be initiated through the menu interface of the system 
controller, or the Dual Nx56/64 can initiate a network loopback 
from a remote unit using a V.54 test pattern.

511 Test Pattern

Forces the Dual Nx56/64 to send a 511 data pattern across the T1 
over all channels to help with debugging.

MAINTENANCE

The Dual Nx56/64 does not require routine hardware maintenance 
for normal operation. ADTRAN does not recommend that repairs be 
attempted in the field. Repair services may be obtained by 
returning the defective unit to ADTRAN. Refer to the warranty for 
further information. Field support for software is provided through 
upgrade facilities.

For more information, refer to the Installation and Maintenance Practice (P/N 61180025L1-5) available 

online at 

www.adtran.com

.

Warranty

:

ADTRAN will replace or repair this product within the warranty period if it does not meet its 

published specifications or fails while in service. Warranty information can be found online 

at 

www.adtran.com/warranty

.

©2008 ADTRAN, Inc. All Rights Reserved.

PRICING AND AVAILABILITY  800.827.0807

TECHNICAL SUPPORT  800.726.8663

RETURN FOR REPAIR  256.963.8722

*61180025L1-22B*

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

CLEI: VAL4NS0D_ _
Product P/N: 1180025L1

Issue Date: 0803

Document P/N: 61180025L1-22B