Issue 4, August 2004

61212073L1-5D

The DS3 NIU3 3-Slot Shelf meets the following 
standards:

• NEBS: Level 3
• ANSI:

T1.404

• UL:

60950

• FCC:

Part 15, Class A

3. INSTALLATION

After unpacking the unit, inspect it for damage or 
missing components. If damage or missing components 
are noted, file a claim with the carrier, then notify 
ADTRAN. Refer to 

Warranty and Customer Service

Install per requirements of NEC NFPA 70. After 
installation, ensure equipment rack stability is not upset.

Location

The NIU3 3-Slot Shelf installs at any location conve-
nient to the customer as a demarcation and loopback 
point for DS3 circuits. The NIU3 can pass both network 
and customer signals up to 900 feet. During NIU3 
bypass operations, if total transmission distance 
exceeds 900 feet, signal quality may degrade. See 

Figure 2

 for maximum recommended transmission 

distances.

Rackmount

NOTE

I n s t a l l   t h e   u n i t   p e r   N E C   N F P A   7 0
requirements. See 

Compliance 

section.

The NIU3 3-Slot Chassis can be rack mounted at any 
convenient location. Reversible mounting flanges 
adjust to desired position in the 19-inch rack. Also 
included are 23-inch flanges. To mount the NIU3 3-Slot 
Chassis in a rack, perform the following steps:

1. Determine desired shelf extension from the rack 

frame.

2. Position the mounting flanges as necessary using 

the appropriate flanges for a 19-inch or 23-inch 
rack. Install using the supplied counter-sink 
screws.

3. Mount the shelf to the rack accordingly.

Wallmount

Additional brackets available from ADTRAN allow the 
chassis to be mounted to a wall. Wallmount bracket 
P/N 1212073L1WM accommodates one 3-Slot Shelf. 

Wallmount bracket P/N 1212078L1WM accommo-
dates a stack of two 3-Slot Chassis. Six ¼ x ¾ inch 
bladed hex-head screws and flat washers are provided 
with the 1212078L1WM wallmount bracket for 
attaching to the wall. In this configuration, the original 
flanges are removed, and the wallmount flanges are 
installed using the countersink screws from the 
originals. If using P/N 1212073L1WM, install the 
chassis so the circuit cards’ front panels face 

up

.

If using P/N 1212078L1WM, install the chassis so the 
circuit cards’ front panels face 

out

. A 2-foot 16 AWG 

ground wire is also provided to be installed between the 
ground termination on the bracket and the ground termi-
nation on the housing. This allows the chassis to rotate 
without disturbing the main ground wire leaving the 
bracket.

CAUTION

W h e n   r o t a t i n g   t h e   c h a s s i s   i n   t h e
1212078L1WM brackets, always do so with
care to ensure that all wiring and connections
are protected. 

CAUTION

There are six removable bypass relays and 1
removable alarm relay located on the rear of
the shelf. After installation, remove the relay
covers and ensure that the relays are properly
and firmly seated in their sockets. Replace the
relay covers.

4. WIRING

Wiring consists of three elements: data, power/ground, 
and alarms. Use suitably sized copper conductors only.

Data

Externally, the shelf backplane has four BNC 
connectors for each of the three NIU3 slots labeled 

NTWK IN

/

OUT

 and 

CUST IN

/

OUT

 (see 

Figure 3

).

Wiring Connections

Connect data wiring per the following procedure:

1. Connect the cables to the BNCs on the backplane 

for those shelf slots that will be populated.

2. If not already done, connect the opposite ends to 

their designated terminations.

3. Dress and lace the wire runs to the bay frames as 

necessary.

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

Содержание DS3 NIU3

Страница 1: ...he backplane circuitry is protected by a metal cover that has openings for BNC data jacks pass through relays power terminal connections and alarm pins Removable covers provide security for power and alarm connections and pass through and alarm relays All connections are clearly labeled Features The NIU3 3 Slot Shelf provides the following features and functions Field replaceable pass through rela...

Страница 2: ...212078L1WM accommo dates a stack of two 3 Slot Chassis Six x inch bladed hex head screws and flat washers are provided with the 1212078L1WM wallmount bracket for attaching to the wall In this configuration the original flanges are removed and the wallmount flanges are installed using the countersink screws from the originals If using P N 1212073L1WM install the chassis so the circuit cards front p...

Страница 3: ... local supply to PWR A 2 Connect the associated return wire to RET A 3 If redundant power is intended make similar connections to PWR B and RET B CAUTION Terminate grounds to an approved ground location Check metal to metal contact on all ground connections Verify ground circuit continuity 4 Connect the common frame ground terminal or ground lug 6 AWG max to an approved ground location CAUTION Per...

Страница 4: ... standards 2 Install all protective shields and panels that were removed for wiring installation 3 Provide power to the backplane 5 TURNUP When an NIU3 is inserted into a shelf with power on the backplane the STATUS LED turns on red while the NIU3 performs a self test If the test passes the STATUS LED turns on green and the other LEDs go through an on off sequence indicating the NIU3 is online If ...

Страница 5: ...cent to the alarm wire wrap pins on the backplane The alarm relay output responds to the card malfunction status on individual NIU3 cards If an alarm condition occurs but an alarm signal is not present then a failed alarm relay is indicated Follow this procedure to replace a failed alarm relay 1 Using an appropriately sized IC extractor tool lift the relay off its socket 2 Align and insert the rep...

Страница 6: ...es support CAPS requests or further information ADTRAN Sales Pricing Availability 800 827 0807 ADTRAN Technical Support Pre Sales Applications Post Sales Technical Assistance 800 726 8663 Standard hours Monday Friday 7 a m 7 p m CST Emergency hours 7 days week 24 hours day ADTRAN Repair CAPS Return for Repair Upgrade 256 963 8722 Repair and Return Address Contact Customer and Product Service CAPS ...

Отзывы: