Section 61245207L2-5, Issue 2
61245207L2-5C
Figure 11
depicts the Self-Test Options Screen. A
test of the FT1-DP and the FNID may be initiated
from this screen.
Figure 12. Provisioning Options Screen
PROVISIONING
___________________________________________________ ______________________
| | |
| PROVISIONS CURRENT SETTINGS | HARDWARE SETTINGS |
| ------------------------------------------ | ----------------- |
| 1. DS1 (FNID) LINE CODE = B8ZS | B8ZS |
| 2. DS1 (FNID) FRAMING = ESF | ESF |
| 3. DS1 (FNID) TX LEVEL = 0 dB | |
| 4. LOOPBACK TIMEOUT = 20 MIN | 20 MIN |
| 5. LATCHING LOOPBACK = ENABLED | ENABLED |
| 6. DSO SEQUENCE = CONTIGUOUS | CONTIGUOUS |
| 7. NUMBER OF DSOS = 12 (768Kbps) | 12 (768Kbps) |
| 8. SIGNALING ENABLED: | |
| 000000000000 | 000000000000 |
| CHANNELS 1 12 | 1 12 |
| “1” INDICATES SIGNALING ENABLED. | |
|___________________________________________________|______________________|
Press: “n” — to change corresponding provision (ex. “2” for FRAMING)
“H” — to copy hardware settings to current settings
“I” — to implement and save current setting changes
“M” — to return to the main menu
Figure 11. Self-Test Options Screen
SELF-TEST
Press “S” to initiate FT1-DP and FNID self-tests.
Press “M” to return to the Main Menu.
Figure 12
shows the Provisioning Options screen.
Settings for all provisioning options may be
configured via the provisioning screen.