TRI-C DP / D4
TRI-C DP
1102182L1
B2
B1
PTRN
L
O
G
I
C
OUT
(Rx)
IN
(Tx)
NORM
AD6
AD5
AD4
AD3
AD2
AD1
NT1
LPTX
CRTX
LPBK
TEST
LP
CR
ACT
TEST
ERR
TRI-C DP / D4
CLEI: D4D3MU0D_ _
■
For a complete Installation and Maintenance Practice: (877) 457-5007, Document # 427. Please have your fax number available.
■
STATUS LEDs
LP
●
●
OFF
TRI loop sync has been established and no Near End Block Errors
(NEBE) are being received from the loop interface
●
RED
TRI-interface is out of sync or there is loss of signal
●
YELLOW
Indicates a BER of 10
-5
has been detected
✷
FLASHING
Flashes upon receipt of a Near End Block Error (NEBE) or when a
BER > 10
-6
is detected during Local Performance Monitoring
CR
●
●
OFF
Carrier sync (framing per TR-TSY-000397) has been established
and no Near End Block Errors are being received frrom the carrier
interface
●
RED
No framing pattern is being received
●
YELLOW
A BER > 10-5 has been detected
✷
FLASHING
Flashes upon receipt of a Near End Block Error (NEBE) or when a
BER > 10-6 is detected during Local Performance Monitoring
ACT
●
GREEN
Layer 1 from the ISDN switch to the customer ISDN terminal
equipment has been established
TEST
●
GREEN
Unit is in Local Performance Monitoring mode or the local test
pattern gen/det in invoked
●
YELLOW
Front panel test has been successssfully initiated or unit is
responding to a 2B+D loopback request
✷
FLASHING
Flashes once every two seconds when responding to a B1 loopback
request or when forced into a B1 loopback from the front panel.
Flashes twice every two seconds when responding to a B2 loopback
request or when forced into a B2 loopback from the front panel.
ERR
✷
FLASHING
Errors detected by local test pattern detector
FACEPLATE SWITCHES
Rotary Switch - used to select circuit elements for loopback testing
■
AD1 – selects address of local unit for loopback
■
AD2 – selects address of next unit downstream for loopback
■
AD3 – selects address of second unit downstream for loopback
■
AD4 – selects address of third unit downstream for loopback
■
AD5 – selects address of fourth unit downstream for loopback
■
AD6 – selects address of fifth unit downstream for loopback
■
LPBK – forces this unit to set up bidirectional loopback for selected B1 or B2 channel
■
CRTX – sets up loopback toward carrier
■
LPTX – sets up loopback toward the loop
■
NT1 – selects address of the NT1 for loopback
■
TEST – initiates selected loopback test from rotary switch
DIP SWITCHES
■
B1/B2 – selects which B channel, B1 or B2, to be tested during local tests
■
NORM/PTRN – used to select whether test pattern is sent from a test set or the unit itself
NORM – test pattern is sent from test set plugged into faceplate bantam jacks
PTRN – test pattern, 2047, is internally generated and transmitted
C A U T I O N
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
LOGIC BANTAM JACKS
■
Used to perform upstream and downstream testing with a DS0 level tester such
as a TPI 108/109 or Fireberd 4000/6000.
Rx (OUT) – transmits signal out to unit being tested
Tx (IN) – receives signal in from unit being tested
HARDWARE SWITCHES SW1 & SW2
SW1-1: TRM – along with SW1-2, selects the bank type for the U-BR1TE IV
SW1-2: TRM
Bank
Count/Slot
SW1-1
SW1-2
D4
D4 Counting
On
Off
D1D Counting
On
On
SLC I
CU in slots 1,4,7,10
On
On
CU in slots 2,5,8,11
Off
Off
SLC III
D4 Counting
On
On
D1D Counting
Off
On
SW1-3: B1 –along with SW4 and SW5, selects the service level
SW1-4: B2
SW1-5: D
Service Option
SW1-3
SW1-4
SW1-5
(B1)
(B2)
(D)
2B+D
On
On
On
2B
On
On
Off
B1+D
On
Off
On
B2+D
Off
On
On
B1
On
Off
Off
B2
Off
On
Off
D
Off
Off
On
SW1-6: Zero Byte Substitution (ZBS)
■
Enables or disables ZBS
Note: ZBS must be set the same for the COT and RT. For AMI-provisioned carriers,
ZBS should be enabled. Setting is optional for B8ZS-provisioned carriers.
COMPLIANCE
This product is intended to be installed
in products providing a Type “B” or “E”
enclosure and in restricted access location
only.
WARRANTY
Warranty for Carrier Networks products manufactured by ADTRAN and supplied
under Buyer’s order for use in the U.S. is ten (10) years. For a complete copy of
ADTRAN’s
U.S. and Canada Carrier Networks Equipment Warranty
, call
(877) 457-5007, Document #414.
Code
Input Output
Power Code (PC)
F
C
Telecommunication Code (TC)
–
X
Installation Code (IC)
A
–
JOB
A
ID
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61102182L1-22A 0105