D4 TOTAL REACH DDS (TRDDB)

The TROCU-R does not invoke a measurable short between tip and ring, thus cable resistance measurements
must be made with a manually applied short.

Power, but No Synchronization

Check cable for load coils.

Note signal meter reading on TROCU-R during power up and synchronization process. Refer to “Signal Loss
Indication” on TROCU-R job aid for definitions. Loop loss may be too great for synchronization to occur.

Ensure loop length is within allowable deployment guidelines.

Relocate the TROCU-R to splice points sequentially closer to the Total Reach DDB to isolate suspect cable 
sections.

Excessive Errors On Loop

Ensure background noise does not exceed 34 dBrn.

Ensure impulse noise is not greater than –40 dBm (+50 dBrn).  

NOTE

: Measure noise with 50 kbit filter.

Compare resistances of individual conductors. If these are different, high-resistance or intermittent opens may
be indicated. A TDR is commonly required to find such faults.

Relocate the TROCU-R to splice points sequentially closer to the Total Reach DDB to isolate suspect cable 
sections.

Trouble Codes

The TRDDB transmits an alternating MOS 9Ah/ASC 9Eh trouble code towards the network under the following fault
conditions:

2-wire DSL loss of signal.

Loss of synchronization.

Open loop.

Quality Monitor disconnect.

The TROCU-R transmits an ASC 9Eh trouble code towards the network from the customer premise for similar 4-wire
customer interface fault conditions.  (Example: mismatched Total Reach and CSU/DSU data rates.)

INSERTION LOSS MEASUREMENTS

Total Reach Design Limits at Traditional 4-wire Frequencies

The table below is for comparison only.  The Total Reach DDS system operates at 13.3 kHz for all customer data rates.

TESTING

The TRDDB supports the following loopbacks and applications:

DS0 latching bidirectional loopback from DS0 test set or remote test center.

Remote end initiated loopbacks from TROCU-R.

Supports 2-wire loop tests from remote end when DDS-DP is in bidirectional loopback.

All existing Total Reach system loopbacks release in response to 35 DDS loop down TIP bytes, by
pressing the LBK button on the TROCU-R, or via a terminal through the DB-9 on the TR OCU-R.

Refer to loopback diagrams for all LBK pushbutton activated tests.

LBK & Pushbutton Tests

Successful loopback tests will show the following LED indication:

Compliance

CAUTION: This product is intended for installation in a restricted access location in a Type B or E
enclosure only.
Normal operation – Loop current will not exceed 22 mA @ -130 Vdc with a maximum power
requirement of 100 mA from -48 Vdc.

WARRANTY

Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyer’s order for use in
the U.S. is ten (10) years.  For a complete copy of ADTRAN’s U.S. Carrier Networks Equipment Warranty state-
ment, call (877) 457-5007, Document #414.

TR

OCU-R

TR

DDB

Data 

Pass-Thru

Bidirectional loopback

Pass-Thru Mode

4-Wire

CPE Interface

TR

OCU-R

Push once for Total Reach

DDB Loopback

Local Loop

ASC 9Eh

Loopback
Pushbutton

Bidirectional loopback

(initiated by CO or Test Center)

TRDDB LBK LED - ON
TROCU-R CUST LBK LED - FLASHING

TRDDB

local loop loopback

TROCU-R CUST LBK LED - FLASHING
TRDDB LBK LED - FLASHING

TR

DDB

Test

Set

Test

Set

4-Wire

CPE Interface

TR

OCU-R

Push twice for Total Reach

OCU-R Loopback

Local Loop

ASC 9Eh

Loopback
Pushbutton

ASC 9Eh

TROCU-R

customer loop loopback

TROCU-R CUST LBK LED - ON
TRDDB LBK LED - OFF

TR

DDB

Test

Set

CODE

INPUT

OUTPUT

Power Code (PC)

F

C

Telcommunication Code (TC)

X

Installation Code (IC)

A

Customer Rate

4-Wire Qualifying Frequency (kHz)

DDS Loss Limit (dB)

2.4

1.2

21

2.4/SC

1.6

23

4.8

2.4

26

4.8/SC

3.2

29

9.6

4.8

33.5

9.6/SC

6.4

37

19.2

9.6

44

19.2/SC

12.8

50

56

28.0

59

56/SC & 64

36.0

61