2
61442480F1-22A
NOTE
■
The Gigabit Ethernet port(s) are optical and therefore are not
classified as any type of port as defined in Appendix B of GR-
1089-CORE.
■
This product is compliant with SFF-8472 “Digital Diagnostics
Monitoring Interface for Optical Transceivers,” Revision 9.3.
■
This product is compliant with the SFP Multi-Source
Agreement (MSA).
■
This product is designed to be deployed in GR-3108-CORE
environmental class 1, class 2 and class 3 as defined in GR-
3108-CORE.
This product meets or exceeds all the applicable requirements of
NEBS, Telcordia GR-63-CORE, GR-1089-CORE, and ETSI EN
300368. This product is intended for deployment in Central Office
type facilities, EEEs, EECs, and locations where the NEC applies
(for example, Customer Premises).
This device complies with Part 15 of the FCC rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN
could void the user's authority to operate this equipment.
This product is designed to meet the following environmental
classes:
■
ETSI EN 300 019-2-1: “
Classification of environmental conditions;
Storage
,” Class 1.2
■
ETSI EN 300 019-2-2: “
Classification of environmental conditions;
Transportation
,” Class 2.3
■
ETSI EN 300 019-2-3: “
Classification of environmental conditions;
Stationary use at weather-protected locations
,” Class 3.2
The equipment is designed to function without degradation
during exposure to all test severities per Class 3.2 of ETSI EN 300
019-1-3.
This product meets EU RoHS Directive 2011/65/EU and/or
applicable exemptions. Refer to
www.adtran.com
for further
information on RoHS/WEEE.
2. Remove the end cap and connect the fiber to the SFP+.
NOTICE
It is recommended that the protective end cap remain on
whenever the transceiver optical fiber connector is not in use.
3. Continue the installation and turn-up of the host module
using the instructions in the Job Aid provided with the
module or other system-level documentation available
online at
www.adtran.com
.
M
AINTENANCE
The SFP+ does not require routine hardware maintenance for
normal operation. ADTRAN does not recommend that repairs be
attempted in the field. Repair services may be obtained by
returning the defective unit to ADTRAN. Refer to the warranty
for further information.
S
AFETY
AND
R
EGULATORY
C
OMPLIANCE
WARNING
!
Read all warnings and cautions before installing or servicing this
equipment.
CAUTION
C
This product uses a Class 1 Laser module that complies with 21
CFR 1040.10 and 1040.11 and IEC 60825-1, IEC 60825-2, EN 60825-
1 and EN 60825-2. For continued compliance with the above
standards, only approved Class 1 laser modules from an
ADTRAN approved vendor list (located on the ADTRAN
website) should be installed in this product. ADTRAN cannot
certify system integrity with other laser modules.
CAUTION
!
■
Electrostatic Discharge (ESD) can damage electronic modules.
When handling modules, wear an antistatic discharge wrist
strap to prevent damage to electronic components. Place
modules in antistatic packing material when transporting or
storing. When working on modules, always place them on an
approved antistatic mat that is electrically grounded.
■
This product is designed and intended only for deployment in
a DC-C (common) bonding and grounding configuration. This
product is not intended or designed for deployment in a DC-I
(isolated) bonding and grounding system.
■
Per GR-1089-CORE the system is designed and intended for
installation as part of a Common Bonding Network (CBN).
The system is not designed nor intended for installation as
part of an Isolated Bonding Network (IBN).
■
The chassis frame ground terminal must be connected to an
earth ground to ensure that the metal enclosure of the SFP is
properly grounded via the backplane connector.