Quick Start Guide, 61700962F1-13B, May 2015

5

To mount the BSAP 2135 to a horizontal pole:
1. Place the lock washers, then the flat washers on the four hex cap screws, and drive the screws 

through the plane bracket into the back of the case as shown in Figure 4.

2. Drive the four round head screws to attach the pole mount base to the plane bracket in a horizontal 

position (Figure 8).

3. Thread the open end of the hose strap through the two tabs on the pole mount base (Figure 9).
4. Install the antennas (sold separately) onto the appropriate antenna ports. The antenna ports are 

labeled 

2.4GHz

 and 

5GHz

.

5. Wrap the hose strap around the horizontal mounting pole and insert the end into the strap lock. 

Tighten the lock of the hose strap to secure the unit to the pole (Figure 11).

S

UPPLYING 

P

OWER TO THE 

BSAP

The BSAP 2135 does not have a power switch. It is powered when connected to a network device that 

supplies PoE based on the IEEE 802.3at standard or an external PoE injector. To power the BSAP 

2135, follow these instructions:

Connect the PoE Cable to the BSAP

8

9

Round Head

Screw

Pole Mount
Base in
Horizontal Position

Hose Strap
Insertion

10

11

Vertical

Pole

Mounting

Horizontal Pole

Mounting

1. Disassemble the watertight fitting by unscrewing the cinch nut and pushing the rubber gasket out 

of the strain-relief fitting.

2. Thread the cinch nut onto the customer-provided RJ-45 CAT 5e or CAT 6 cable.
3. Spread the gasket open and wrap it around the cable near the RJ-45 connector.
4. Insert the RJ-45 connector through the strain-relief fitting, and press the gasket back into its 

original position.

5. Insert the connector into the RJ-45 receptacle on the bottom of the BSAP.
6. Gently push the strain-relief fitting along the cable until it engages with the black threads, and 

screw it onto the BSAP until it is well seated against the unit.

7. Screw the cinch nut onto the strain-relief fitting until it is well seated against the gasket forming a 

watertight seal.

Connect the BSAP to a PoE Source

The BSAP 2135 requires 802.3at PoE. It will not function using 802.3af PoE. The following diagram 

illustrates how to provide power to the BSAP 2135 installed outdoors. Three examples are provided:
1. A PoE switch providing power in conjunction with NetVanta PoE Protector/Injector (1702595F15) 

installed indoors.

2. A non-PoE switch in conjunction with NetVanta PoE Protector/Injector (1702595F15) and an 

optional AC Power Adapter (1700501F1) to provide power installed indoors.

3. A third-party outdoor rated 802.3at PoE injector (PowerDsine PD-9001GO) or equivalent with 

GR-1089-Core Criteria B Surge Protection installed outdoors with mesh.

For outdoor applications, the watertight fitting must be used when 

connecting PoE cables to the BSAP 2135. Failure to use the watertight 

fitting when the unit is installed outdoors will void the user's warranty and 

could create a fire or shock hazard.

5GHz

5GHz

Cinch Nut

Gasket

Strain-relief 
Fitting

Antenna

Connectors

RJ-45 Receptacle
and Connector

Содержание BLUESOCKET 2135

Страница 1: ...luded These connectors support two internal 802 11 radios one 2 4 GHz 802 11b g n radio and one 5 GHz 802 11a n ac radio There are three antenna connectors for each band labeled 2 4GHz and 5GHz A set of six high efficiency omnidirectional antennas can be ordered from ADTRAN for the BSAP 2135 P N 1700930F1 three 5 GHz 7 dBi gain and three 2 4 GHz 5 dBi gain Make a note of the 12 character MAC addre...

Страница 2: ...n 8 mm diameter hole with a depth of 36 to 38 mm into each of the markings Figure 2 3 Hammer the expanding bolts into each of the drilled holes Figure 3 4 Place the lock washers then the flat washers on the four hex cap screws and drive the screws through the plane bracket into the back of the case Figure 4 5 Install the antennas sold separately onto the appropriate antenna ports The antenna ports...

Страница 3: ...et into the back of the case as shown in Figure 4 2 Using the four round head screws with washers and lock washers attach the pole mounting bracket to the plane bracket in a vertical position Figure 6 3 Thread the open end of the hose strap through the two tabs on the pole mount base Figure 7 4 Install the antennas sold separately onto the appropriate antenna ports The antenna ports are labeled 2 ...

Страница 4: ...o the appropriate antenna ports The antenna ports are labeled 2 4GHz and 5GHz 5 Wrap the hose strap around the horizontal mounting pole and insert the end into the strap lock Tighten the lock of the hose strap to secure the unit to the pole Figure 11 SUPPLYING POWER TO THE BSAP The BSAP 2135 does not have a power switch It is powered when connected to a network device that supplies PoE based on th...

Страница 5: ...t seal Connect the BSAP to a PoE Source The BSAP 2135 requires 802 3at PoE It will not function using 802 3af PoE The following diagram illustrates how to provide power to the BSAP 2135 installed outdoors Three examples are provided 1 A PoE switch providing power in conjunction with NetVanta PoE Protector Injector 1702595F15 installed indoors 2 A non PoE switch in conjunction with NetVanta PoE Pro...

Страница 6: ... voltage events will void the user s warranty PowerDsine PD 9001GO Outdoor 802 3at PoE Injector or Equivalent with GR 1089 Core Criteria B Surge Protection NetVanta PoE Protector Injector 1702595F15 with Optional AC Power Adapter 1700501F1 Non PoE Switch NetVanta PoE Protector Injector 1702595F15 PoE Switch INDOORS OUTDOORS To Earth Ground BSAP 2135 with Built in Ethernet and Antenna Surge Protect...

Страница 7: ... to receive its configuration information This AP discovery process uses an algorithm that attempts discovery methods in this order static configuration DHCP vendor option 43 Domain Naming System DNS discovery and cached vWLAN information If no response to the discovery request is received the algorithm moves to the next method in the list except when using static configuration which never queries...

Страница 8: ...ne at https supportforums adtran com CONFIGURING THE APPLICATION More detailed documentation for configuring the BSAP 2135 is provided in the Bluesocket vWLAN Administrator s Guide available online at https supportforums adtran com FCC RADIO FREQUENCY INTERFERENCE This device complies with Part 15 of the Federal Communications Commission FCC rules The operation of this device is subject to the fol...

Отзывы: