Chapter 11. SNMP Management
61200180L1-1
ATLAS 800 User Manual
11-5
When one of the Current Alert thresholds is exceeded, the corresponding
event bit is set to 1 in the adDS1CurrentAlert variable in the DS1 alert table.
When enabled, ATLAS sends alert traps to each member of the trap destina-
tion list upon detecting status bit changes in adDS1CurrentAlert. If you have
previously set the corresponding enable bit = 1 in the adDS1CurrentArm
variable and adDS1AlertEnable = On, then ATLAS sends an alert trap mes-
sage. A single alert trap message may report multiple event changes. ATLAS
clears the event bits after sending the trap message or sending the response
to a Get request for the adDS1CurrentAlert variable. ATLAS clears the Current
Alert values at the beginning of a new 15-minute interval. Total Alert values
are cleared at the beginning of a new 24-hour interval.
Table 11-5 shows the Total Alert Traps, which describe events that have oc-
curred in the last 24-hour interval.
adATLAS800CurrentCSS
Warning
The current interval path code violations have been
exceeded.
adATLAS800CurrentLES
Warning
The current interval line errored second threshold has
been exceeded.
adATLAS800CurrentCV
Warning
The current interval line code violation threshold has
been exceeded.
Table 11-4. DS1 Current Alert SNMP Traps (Continued)
Current Alert
Severity
Description
Table 11-5. Total Alert Traps
Total Alert
Severity
Description
adATLAS800TotalES
Warning
The total interval errored second threshold has been
exceeded.
adATLAS800TotalSES
Warning The total interval severely errored second threshold has
been exceeded.
adATLAS800TotalSEFS
Warning
The total interval severely errored framing second threshold
has been exceeded.
adATLAS800TotalUAS
Major
The total interval unavailable second threshold has been
exceeded.
adATLAS800TotalCSS
Warning
The total interval controlled slip second threshold has been
exceeded.
adATLAS800TotalPCV
Warning
The total interval path code violations has bee exceeded.
adATLAS800TotalLES
Warning
The total interval line errored second threshold has been
exceeded.
adATLAS800TotalLCV
Warning
The total interval line code violation threshold has been
exceeded.
Содержание ATLAS 800 Series Module QUAD E1
Страница 1: ...ATLAS 800 User Manual Part Number 1200180L1 Part Number 1200227L1 61200180L1 1B March 1999...
Страница 12: ...xii...
Страница 22: ...List of Tables xxii ATLAS 800 User Manual 61200180L1 1...
Страница 28: ...Chapter 1 Introducing the ATLAS 800 1 6 ATLAS 800 User Manual 61200180L1 1...
Страница 42: ...Chapter 3 Operating the ATLAS 800 3 6 ATLAS 800 User Manual 61200180L1 1...
Страница 60: ...Chapter 5 Navigating the Terminal Menu 5 6 ATLAS 800 User Manual 61200180L1 1...
Страница 94: ...Chapter 8 Dedicated Maps Terminal Menu 8 10 ATLAS 800 User Manual 61200180L1 1...
Страница 122: ...Chapter 9 Dial Plan Terminal Menu 9 28 ATLAS 800 User Manual 61200180L1 1...
Страница 162: ...Appendix A System Event Logging A 14 ATLAS 800 User Manual 61200180L1 1...
Страница 166: ...Appendix B Troubleshooting B 4 ATLAS 800 User Manual 61200180L1 1...
Страница 190: ......