ATLAS 550 (DC SYSTEM)

P/N 1200550L2

For more detailed documentation, visit us online at  

www.adtran.com

Quick Start Guide

Quick Start Guide, 61200550L2-13A, June 2003

Technical Support 1-888-4ADTRAN (1-888-423-8726)

 2003 ADTRAN, All Rights Reserved

O

I

ALL

 EMPTY

 SLOTS MUST

 BE

COVERED WITH BLANK P

ANELS

500 Series

500 Series

500 Series

CAUTION: FOR CONTINUED PROTECTION

AGAINST RISK OF FIRE, REPLACE ONLY

WITH SAME TYPE AND RATING OF FUSE.

ETHERNET

ADMIN

RELAY

ALARM

MON

COM

NO

NC

500 Series

NETWORK 2

NETWORK 1

500 Series

500 Series

1

2

3

4

DC Power Connection

Option Module Slots

 Alarm Relay 

Connection

Network Module Slots

10/100BaseT Ethernet

Admin Port

 External Relay Connection

Reviewing the Rear Panel

Admin Interface Pinout

10/100BaseT Ethernet Interface Pinout

External Relay Connection Pinout

PIN

NAME

DESCRIPTION

1

SG

Signal Ground

2

RTS

Request to Send (output), follows CTS

3

TD

Transmit Data (input)

4

DTR

Data Terminal Ready (output), +12 V

5

RD

Receive Data (output)

6

DCD

Data Carrier Detect (input)

7

Not Connected

8

CTS

Clear to Send (input)

PIN

NAME

DESCRIPTION

1

TX1

Transmit Positive

2

TX2

Transmit Negative

3

RX1

Receive Positive

4,5

Unused

6

RX2

Receive Negative

7, 8

Unused

PIN

NAME

DESCRIPTION

1

Alarm Out

Outputs EIA-232 level signal for connection to external alarm contacts.

2

Alarm In

Monitors signal coming from external alarm contacts.

Alarm Relay Connection Pinout

DC Power Supply Connection

PIN

NAME

DESCRIPTION

1

Normally Closed (NC)

Opens when a selected alarm condition is present.

2

Normally Open (NO)

Closes when a selected alarm condition is present.

3

Common (COM)

Common connection between external circuitry and NC or 
NO terminal.

4

Chassis Ground (GND)

PIN

NAME

+24 VDC Sorce

-48 VDC Sorce

1

+

+24 VDC

Ground (GND)

2

-

Ground (GND)

-48 VDC

Connecting Power to the ATLAS 550

The DC-powered ATLAS 550 comes equipped with a DC power supply to furnish 
the voltages necessary for proper backplane operation. As shipped, the ATLAS 
550 is set to factory default conditions. After installing the unit and any option 
modules, the ATLAS 550 is ready for power-up.

• Power to the ATLAS 550 DC system must be from a reliably grounded -48 VDC or
• +24 VDC source which is electrically isolated from the AC source.
• Install this unit in accordance with Article 400 and 364.8 of the NEC NFPA 70.
• The branch circuit overcurrent protection shall be a fuse or circuit breaker rated 

minimum 60 VDC, maximum 10A.

• A readily accessible disconnect device that is suitably approved and rated shall be 

incorporated in the field wiring.

• Maximum recommended ambient operating temperature is 45ºC.