background image

2

61445019F3C-13A

product is intended for deployment in Central Office type 
facilities, EEEs, EECs, and locations where the NEC applies 
(for example, Customer Premises.

This product and the host system are designed and intended 
for installation as part of a Common Bonding Network (CBN). 
This product and the host system are not designed nor 
intended for installation as part of an Isolated Bonding Network 
(IBN).

This product does not have an internal DC connection 
between battery return and frame ground. This product can be 
installed in a DC-I (isolated) or DC-C (common) configuration.

The chassis frame ground terminal must be connected to an 
earth ground to ensure that the exposed metal (i.e., front 
panels, SFP/XFP modules) on the product is properly 
grounded.

g

     NOTE

The Gigabit Ethernet port(s) are optical and therefore are not 
classified as any type of port as defined in Appendix B of GR-
1089-CORE.

This product is designed to be deployed in GR-3108-CORE 
environmental class 1.

This product is NRTL Listed to the applicable UL Standards. 
The product is designed to meet the applicable requirements 
of Telcordia GR-63-CORE and GR-1089-CORE.

This product has also been evaluated to international safety 
standards EN 60950-1, AS/NZS 60950.1, and IEC 60950-1. 
This product meets the requirements for CE marking under the 
EMC Directive and Low Voltage Directive. Standards used to 
demonstrate Compliance are EN 300 386 and EN 60950.

This device complies with Part 15 of the FCC rules. Operation 
is subject to the following two conditions:

1. This device may not cause harmful interference.
2. This device must accept any interference received, including 

interference that may cause undesired operation.

Changes or modifications not expressly approved by ADTRAN 
could void the user's authority to operate this equipment.

This product is designed to meet the following environmental 
classes:

ETSI EN 300 019-2-1 “Classification of environmental condi-
tions; Storage Class” 1.2

ETSI EN 300 019-2-2 “Classification of environmental condi-
tions, Transportation”, Class 2.3

ETSI EN 300 019-2-3 “Classification of environmental condi-
tions, Stationary use at weather protected locations”, Class 
3.1E

This product is designed to function without degradation during 
exposure to all test severities per Class 3.3 of ETSI EN 300 
019-2-3.

This product meets EU RoHS Directive. Refer to 

www.adtran.com

 for further information on RoHS/WEEE.

O

PERATIONAL 

S

PECIFICATIONS

General

Module type: QSFP28

Fiber/Copper: Fiber

SM/MM: Multimode Fiber

Applications: 40 GbE and 10 GbE break-out applications, High 
performance computing interconnect

Distance: Different lengths from 3,10,15, 20, 30, 50, and 100 
meters

Digital Diagnostic Monitoring: SFF8636 Compliant 

Optical

 

Transmitter

Laser Diode Type: VCSEL Array 

Tx Central Wavelength: 850 nm

Receiver

Rx Type: PIN Array

Rx Central wavelength: 850 nm

Environmental

 

Controlled Environment (Commercial Grade)

Operational temperature range: –5°C  to + 50°C

Storage temperature range: –40°C  to +85°C

Relative humidity to 80%, noncondensing

S

AFETY AND 

R

EGULATORY

E

NGLISH

f

     

WARNING!

Read all warnings and cautions before installing or servicing this 
equipment.

C

     

CAUTION!

     

This product contains or uses a Class 1 Laser module that 
complies with FDA 21 CFR 1040.10, 1040.11 and IEC 60825-1. 
For continued compliance with the above standards, only 
approved Class 1 laser modules from an ADTRAN approved 
vendor list (located on the ADTRAN website) should be installed 
in this product. ADTRAN cannot certify system integrity with other 
laser modules.

f

     

CAUTION!

Electrostatic Discharge (ESD) can damage electronic 
modules. When handling modules, wear an antistatic 
discharge wrist strap to prevent damage to electronic 
components. Place modules in antistatic packing material 
when transporting or storing. When working on modules, 
always place them on an approved antistatic mat that is 
electrically grounded.

The SFP meets or exceeds all the applicable requirements of 
NEBS, Telcordia GR-63-CORE, and GR-1089-CORE. The 

Содержание AOC QSFP28 100G AOC QSFP28 100G 3M

Страница 1: ...P28 into an appropriate module complete the following steps 1 Inspect the AOC QSFP28 If damaged file a claim with the carrier and then contact ADTRAN Customer Service 2 Do not remove the protective end cap from the QSFP until the fiber optic cable is ready to be connected 3 Insert the AOC QSFP28 into the QSFP cage on the module Ensure the manufacturer s label on the QSFP is facing upward for corre...

Страница 2: ...019 2 1 Classification of environmental condi tions Storage Class 1 2 ETSI EN 300 019 2 2 Classification of environmental condi tions Transportation Class 2 3 ETSI EN 300 019 2 3 Classification of environmental condi tions Stationary use at weather protected locations Class 3 1E This product is designed to function without degradation during exposure to all test severities per Class 3 3 of ETSI EN...

Страница 3: ...niveaux de sévérité suivant les spécifications de la classe 3 3 de l ETSI EN 300 019 2 3 Ce produit est conforme à la directive Reportez vous à www adtran com pour de plus amples renseignements sur RoHS WEEE DEUTSCH f WARNUNG Lesen Sie sich alle Warn und Sicherheitshinweise durch bevor Sie dieses Gerät installieren oder warten C VORSICHT DasProdukt enthält oder verwendet Klasse 1 Laser Module die ...

Страница 4: ...TOMER CARE From within the U S 1 888 423 8726 From outside the U S 1 256 963 8716 PRICING AND AVAILABILITY 1 800 827 0807 61445019F3C 13A Documentation for ADTRAN Network Solutions products is available for viewing and download directly from the ADTRAN Support Community website Go to https supportforums adtran com welcome Registration is required ADTRAN offers training courses on our products incl...

Отзывы: