background image

2

Issue 1

61200385L1-5A

1.

If present, remove the cover plate from the appro-
priate option slot of the Total Access 850 chassis.

2.

Position the module to fit in the lower and upper 
grooves.

3.

Slide the module into the option slot pressing 
equally on the top and bottom of the faceplate until 
the module is firmly positioned against the back of 
the chassis.

4.

Push in the ejector on the lower left-hand side of 
the module to finish seating the module.

Auto-detection of Modules

The Total Access 850 RCU automatically detects the 
presence of the Total Access 850 DSX-1 Module when 
the module is installed into the system. You are not re-
quired to reboot.

 

Wiring Connections

The Total Access 850 DSX-1 Module connects to two 64-
pin Champ connectors located on the backplane. (Pi-
nouts are given in the System Manual, Section 2Engi-
neering Guidelines.)

Faceplate LEDs

The faceplate LED colors are described below.

4. USING THE MODULE

You can configure and control the Total Access 850 
DSX-1 Module from a variety of sources, including the 
following:

• The terminal menus, allowing detailed configura-

tion, status, and diagnostics via the  DB-9 craft port 
on the front of the card, the RJ-45 craft port on the 
rear of the chassis, or telnet. 

The Terminal Menus

The terminal menus are available by using either a 
VT-100 terminal attached to the Total Access 850 active 
RCU’s craft port, the chassis’ ADMIN port, or a Telnet 
session established through the RCU’s Ethernet port. 
The Total Access 850 System Manual provides detailed 
instructions on using any of these management ap-
proaches.

Terminal Menu Structure

The Total Access 850 uses a hierarchical menu structure 
to provide access to all of its features. The top-most 
menu level leads to submenus which are grouped by 
functionality. All menu items display in the terminal 
window. 

Accessing the Module Terminal Menus

Once you are connected to a terminal, press 

Enter

 sev-

eral times until a 

L

OGIN

 prompt displays. Enter the de-

fault, password, in lowercase characters (the login 
system is case sensitive). TheTotal Access 850 upper-
level 

S

YSTEM

 I

NFO

 menu opens.

To access the terminal menu for the Total Access 850 
DSX-1 Module:

1.

Use the arrow keys to navigate to the 

M

ODULES

 

menu and press 

Enter

.

2.

Select the module by using the arrow keys to high-
light the specific module.

3.

Press 

Enter

 while the module slot is highlighted.

Menu options for the module now display on the terminal.

Passwords

To edit fields in the terminal menus, you must have the 
appropriate password level. Each menu description in 
this section indicates the password level required for 
write and read access. Security level 

F

ULL

 users can 

view and edit every available field. Security level 

S

TATUS

 users can view most fields but cannot edit. 

I

NTERFACES

 M

ENU

DSX card identifies the Total Access 850 DSX-1 Module. 
The following sections describe the 

I

NTERFACES

 menu 

options: 

I

NTERFACE

, C

ONFIG

 and 

T

EST

.

Dangerous voltage is exposed when the 
cover plate is removed.

ONLINE LED Colors

Description

Off

No power present

Amber

Channel test in progress

Blinking Amber

Card initializing during 
startup

Green

DSX-1 signal present & 
synchronized; channel is 
configured for use

Red

Channel alarm present

The remainder of this document describes 
the menu items available when managing 
the Total Access 850 DSX-1 Module via 
the terminal menus.

Refer to the Total Access 850 System 
Manual for detailed instructions on navi-
gating through the terminal menu.